Dry bath incubators: dry block, cooling, bead bath, hybridization and biological indicator incubators
Dry bath incubators give precise and stable temperature for tubes, vials and microplates in interchangeable aluminium blocks, without water. COLO.Science supplies heating and heating-cooling models, bead baths, hybridization systems and incubators for biological indicators. This category helps you choose by temperature range, number of blocks, tube format and whether a heated lid or cooling is needed.
- Microbiology — all microbiology equipment
- Microbiological Incubators — parent group
- Dry bath incubators (heating) — ALEMADR-MB, ALEMADR-MB2, ALEMADR-SO, ALEMADR-SB, ALEMADR-MI, ALEMADR-MO, ALEMADR-DB, DBATH100
- Dry bath incubators with cooling — ALEMADR-MC, ALEMADR-SOC, ALEMADR-DBC
- Bead bath — ALEMADR-BB
- Hybridization — ALHYB, ALHYB-OV
- Biological indicator incubators — BIOIND, BIOIND100
- Thermo blocks — interchangeable blocks for tubes, vials and plates
A heated aluminium block holds tubes, vials or plates at a set temperature without water. For enzyme reactions, sample pre-incubation, denaturation and routine heating.
- ALEMADR-MB — mini format for a few tubes on the bench
- ALEMADR-MB2 — mini, built-in block, 12 V DC supply, RT+5 to 100 °C
- ALEMADR-SO — one interchangeable block, RT+5 to 100 °C
- ALEMADR-SB — 1, 2 or 4 blocks, up to 160 °C
- ALEMADR-MI — two blocks with two independent temperature zones
- ALEMADR-MO — four timers, up to 110 °C
- ALEMADR-DB — heated lid against condensation in the tube caps
- DBATH100 — RT+5 to 160 °C
Heating and cooling in one block, for work below room temperature: sample storage on the bench, enzyme inactivation steps and temperature-sensitive reagents.
- ALEMADR-MC — mini format, RT−15 to 100 °C
- ALEMADR-SOC — one block, RT−30 to 100 °C
- ALEMADR-DBC — heated lid, RT−25 to 100 °C
Metal beads replace water and blocks: vessels of any shape stand directly in the bath, with no water to change and a lower contamination risk.
- ALEMADR-BB — heated lid, RT+5 to 100 °C
Controlled temperature for hybridization of slides, membranes and blots.
Incubation of self-contained biological indicators for checking steam and other sterilization cycles.
Start from the temperature range: above room temperature only, or with cooling. Then the number of blocks and zones you need at once, and the tube format — the block is chosen separately for each tube, vial or plate type. A heated lid is recommended for small volumes and longer incubations.
COLO.Science prepares the complete configuration — instrument and blocks — according to your tubes, temperatures and number of samples.
Dry Bath Incubator Categories
Dry Bath Incubator
Showing all 16 results