COLO.Science · Spectroscopy & Color · UV/Vis spectrophotometers
NOVEL-102S UV-Vis double beam spectrophotometer — 190–1100 nm, spectral bandwidth 2 nm
The NOVEL-102S UV-Vis double beam spectrophotometer measures every sample against a reference beam across 190–1100 nm. Deuterium and tungsten lamps, a Czerny-Turner monochromator with a 1200 lines/mm grating and a spectral bandwidth of 2 nm give stable UV and visible readings during long scans and kinetics; the wavelength is set automatically and everything is operated from the 8″ colour touch screen.
Double beam measurement for scans, kinetics and low absorbance
In a single beam instrument a change of lamp intensity after the blank appears directly in the result. The NOVEL-102S splits the light into a sample and a reference beam and measures both, so the baseline stays flat (≤±0.002 A) and drift stays below 0.0009 A/h. That matters for full-spectrum scans, long kinetic runs and samples with low absorbance — the typical work of a UV-Vis double beam spectrophotometer.

Key characteristics
- Double beam optics, Czerny-Turner monochromator, 1200 lines/mm grating, 160 mm focal length
- Wavelength range 190–1100 nm, spectral bandwidth 2 nm, deuterium and tungsten lamps
- Wavelength accuracy ±0.3 nm, repeatability ≤0.1 nm, automatic wavelength setting
- Photometric accuracy ±0.002 A (0–0.5 A); stray light ≤0.03 %T; baseline ≤±0.002 A; drift ≤0.0009 A/h
- Full-spectrum scanning, peak/valley detection, GOTO λ, multi-wavelength, kinetics, linear regression
- 8″ colour touch screen, internal memory and USB; single 10 mm cell holder, 2 quartz and 4 glass cuvettes
Suitable for
- Life science and biochemistry: DNA, RNA and protein at 260/280 nm, enzyme kinetics
- Pharmaceutical quality control with UV and visible methods
- Water, wastewater and environmental laboratories
- Food, beverage and agricultural laboratories
- Clinical chemistry, teaching and research laboratories that need one instrument for UV and Vis
Why a UV-Vis double beam spectrophotometer
A UV-Vis double beam spectrophotometer compares the sample with the reference at every point of the measurement. Lamp warm-up, ageing and mains fluctuations are compensated, so a spectrum recorded over minutes or a kinetic curve over an hour is not distorted by the instrument. The NOVEL-102S brings this to routine laboratories at the price level of the NOVEL platform.
For series of samples with an automatic 8-cell holder choose the NOVEL-100S; for selectable bandwidth from 0.5 to 5 nm and the lowest stray light choose the NOVEL-900.
Cell holders and sample handling
The NOVEL-102S measures 10 mm cuvettes in a single cell holder in the sample beam; quartz cuvettes are used for the UV range, glass cuvettes for the visible range. 2 quartz and 4 glass cuvettes are included.
NOVEL-102S UV-Vis double beam spectrophotometer — technical specifications
Optics and photometry
| Optical system | Double beam, Czerny-Turner monochromator |
| Grating · focal length | Holographic, 1200 lines/mm · 160 mm |
| Light source | Deuterium lamp and tungsten-halogen lamp |
| Wavelength range | 190–1100 nm |
| Spectral bandwidth | 2 nm |
| Wavelength accuracy | ±0.3 nm |
| Wavelength repeatability | ≤0.1 nm |
| Photometric accuracy | ±0.3 %T; ±0.002 A (0–0.5 A); ±0.004 A (0.5–1 A) |
| Photometric repeatability | ≤0.15 %T; 0.001 A (0–0.5 A); 0.002 A (0.5–1 A) |
| Photometric range | 0–200 %T; −0.301 to 4.000 A; 0–9999 C |
| Stray light | ≤0.03 %T at 220 nm (NaI) and 360 nm (NaNO₂) |
| Baseline flatness · drift | ≤±0.002 A (200–1090 nm) · ≤0.0009 A/h |
| Noise | ≤0.15 %T at 100 %T · ≤0.1 %T at 0 %T |
| Detector | Silicon photocell |
Functions, data and general
| Measuring modes | T, A, C |
| Functions | Full-spectrum and detailed scanning, peak/valley, GOTO λ, multi-wavelength |
| Scanning speed | Fast · medium · slow |
| Quantitative analysis | Concentration direct reading; linear regression |
| Kinetics | Time-based kinetics |
| Cell holder | Single cell holder, 10 mm (standard) |
| Display | 8″ colour touch screen |
| Data output | USB, PC connection |
| Printer · PC software | Thermal printer · COLO spectrum software (options) |
| Conformity | CE |
| Power supply | AC 220 V ±22 V, 50 Hz ±1 Hz, 200 W |
| Packing size · gross weight | 700 × 580 × 500 mm · 32 kg |
Operation and data

The NOVEL-102S is operated from an 8 inch touch screen: wavelength, method and units are set on the screen; spectra, regression curves and kinetic plots are shown while the measurement runs. Zero and 100 %T are adjusted automatically, and concentration is read directly or from a linear regression.
Results, spectra, regression equations and correction data are kept in the internal memory, so the instrument starts quickly. The deuterium and tungsten lamps can be switched separately to extend their life. Via USB the NOVEL-102S connects to a PC; a thermal printer and the COLO spectrum PC software are available as options.
Standard delivery
- NOVEL-102S UV/Vis double beam spectrophotometer with 8″ touch screen
- Single cell holder, 10 mm
- 4 × glass cuvette and 2 × quartz cuvette, 10 mm path length
- Power cable, 2 fuses and operation manual
Optional: thermal printer and COLO spectrum PC software. The delivered configuration for a specific order is the one confirmed in the COLO.Science quotation.
Knowledge base
Spectral bandwidth, stray light, Beer–Lambert law and the choice of cuvettes are explained on COLO.Science — UV-Vis spectrophotometry and colour measurement, our knowledge base; how absorbance fits among other laboratory measurements is described in Measurement in laboratory science. The full data are in the NOVEL-102S technical specification (PDF).
Selection guide
- Double beam stability at an entry price: NOVEL-102S UV-Vis double beam spectrophotometer — 190–1100 nm, 2 nm, 8″ touch screen.
- UV and Vis routine in series of samples: NOVEL-100S — split beam, automatic 8-cell holder.
- Compact single beam UV/Vis at 2 nm: NOVEL4S — 190–1100 nm, 7″ touch screen.
- Several bandwidths in one single-beam instrument: MAVRICA18 or LEGEND series — bandwidth from 0.5 to 5 nm.
- Long sequences, baseline stability, resolution checks: NOVEL-900 double beam with selectable 0.5–5 nm.
- GLP data management or higher sensitivity: MAVRICA-T series for GLP/GMP data, or LEGEND-PMT double beam with PMT detector.
Configuration notice
This page is provided for orientation and product selection. Cell holders, cuvettes, printer, software and other options are confirmed with the official COLO.Science quotation.
Sales and support for international customers
COLO Lab ExpertsPolje ob Sotli 4, SI-3255 Buče, Slovenia
Phone: +386 70 713 437 · Email: sales@colo.si · Web: colo.si
We supply laboratories across Europe directly and through partners. B2B prices are quoted net, excluding VAT.