NOVEL-900 High Resolution UV/Vis Double Beam Spectrophotometer, 190–1100 nm, 0.5–5 nm

Availability:

Available on backorder


COLO.Science · High resolution UV-Vis spectrophotometer

190–1100 nm · bandwidth 0.5 / 1 / 2 / 4 / 5 nm · double beam · 1600 lines/mm · stray light ≤0.02 %T · baseline ≤±0.0008 A · 8″ touch screen

COLO.Science · Spectroscopy & Color · UV/Vis spectrophotometers

NOVEL-900 high resolution UV-Vis spectrophotometer — double beam, 190–1100 nm, 0.5–5 nm

The NOVEL-900 high resolution UV-Vis spectrophotometer is a double beam instrument for 190–1100 nm with five selectable spectral bandwidths: 0.5, 1, 2, 4 and 5 nm. Its Czerny-Turner monochromator with a 1600 lines/mm grating and 200 mm focal length keeps stray light at ≤0.02 %T and the baseline within ±0.0008 A; deuterium and tungsten lamps, automatic wavelength setting and the 8″ colour touch screen complete the instrument.

What the spectral bandwidth changes

The spectral bandwidth is the width of the wavelength band that passes the monochromator. A narrow band of 0.5 or 1 nm separates close and narrow absorption peaks and gives true peak heights; a wider band of 4 or 5 nm lets more light through, which lowers noise with weak, dense or turbid samples. The NOVEL-900 switches between 0.5, 1, 2, 4 and 5 nm on the touch screen, so one double beam instrument covers both resolution work and routine measurements.

NOVEL-900 high resolution UV-Vis spectrophotometer with 8 inch touch screen

Key characteristics

  • Double beam optics, Czerny-Turner monochromator, 1600 lines/mm grating, 200 mm focal length
  • Wavelength range 190–1100 nm, spectral bandwidth 0.5 / 1 / 2 / 4 / 5 nm, deuterium and tungsten lamps
  • Wavelength accuracy ±0.3 nm, repeatability ≤0.1 nm, automatic wavelength setting
  • Photometric accuracy ±0.002 A (0–0.5 A); stray light ≤0.02 %T; baseline ≤±0.0008 A; noise ≤0.1 %T
  • Full-spectrum scanning, peak/valley detection, GOTO λ, multi-wavelength, kinetics, linear regression
  • 8″ colour touch screen, internal memory and USB; single 10 mm cell holder, 2 quartz and 4 glass cuvettes; 50 and 100 mm cell holders as options

Suitable for

  • Life science and biochemistry: DNA, RNA and protein at 260/280 nm, enzyme kinetics
  • Pharmaceutical quality control with UV and visible methods
  • Water, wastewater and environmental laboratories
  • Food, beverage and agricultural laboratories
  • Clinical chemistry, teaching and research laboratories that need one instrument for UV and Vis

Why a high resolution UV-Vis spectrophotometer

Many methods state the bandwidth they need: pharmacopoeia resolution checks with toluene in hexane, spectra of benzene-type compounds, rare-earth or holmium bands and derivative spectra need 1 nm or less, while concentration methods in water or food work well at 2 nm and above. With a fixed 2 nm instrument narrow peaks are broadened and their height drops; the NOVEL-900 lets you choose 0.5 nm for such spectra and return to 2–5 nm for routine work, with the same stray light (≤0.02 %T) and baseline (≤±0.0008 A).

For low stray light at a fixed 2 nm and a lower price choose the NOVEL-800; for an entry-level double beam instrument the NOVEL-102S.

Cell holders and sample handling

The NOVEL-900 measures 10 mm cuvettes in a single cell holder in the sample beam; quartz cuvettes are used for the UV range, glass cuvettes for the visible range. 2 quartz and 4 glass cuvettes are included. For low concentrations, cell holders for 50 mm and 100 mm path length are available as options.

Quartz and glass cuvettes — NOVEL-900
Quartz and glass cuvettes2 quartz and 4 glass cuvettes, 10 mm, in standard delivery.
Standard
Single cell holder 10 mm — NOVEL-900
Single cell holder 10 mmFixed position in the sample beam — standard.
Standard

NOVEL-900 high resolution UV-Vis spectrophotometer — technical specifications

Optics and photometry

Optical system Double beam, Czerny-Turner monochromator
Grating · focal length 1600 lines/mm · 200 mm
Light source Deuterium lamp and tungsten-halogen lamp
Wavelength range 190–1100 nm
Spectral bandwidth 0.5 / 1 / 2 / 4 / 5 nm (selectable)
Wavelength accuracy ±0.3 nm
Wavelength repeatability ≤0.1 nm
Photometric accuracy ±0.3 %T; ±0.002 A (0–0.5 A); ±0.004 A (0.5–1 A)
Photometric repeatability ≤0.15 %T; 0.001 A (0–0.5 A); 0.002 A (0.5–1 A)
Photometric range 0–200 %T; −0.301 to 4.000 A; 0–9999 C
Stray light ≤0.02 %T at 220 nm (NaI) and 360 nm (NaNO₂)
Baseline flatness ≤±0.0008 A (200–1090 nm)
Noise ≤0.1 %T at 100 %T · ≤0.02 %T at 0 %T
Detector Silicon photocell

Functions, data and general

Measuring modes T, A, C
Functions Full-spectrum and detailed scanning, peak/valley, GOTO λ, multi-wavelength
Scanning speed Fast · medium · slow
Quantitative analysis Concentration direct reading; linear regression
Kinetics Time-based kinetics
Cell holder Single cell holder, 10 mm (standard)
Display 8″ colour touch screen
Data output USB, PC connection
Printer · PC software Thermal printer · COLO spectrum software (options)
Conformity CE
Power supply AC 220 V ±22 V, 50 Hz ±1 Hz, 200 W
Packing size · gross weight 740 × 630 × 450 mm · 35 kg

Operation and data

NOVEL-900 high resolution UV-Vis spectrophotometer

The NOVEL-900 is operated from an 8 inch touch screen: wavelength, method and units are set on the screen; spectra, regression curves and kinetic plots are shown while the measurement runs. Zero and 100 %T are adjusted automatically, and concentration is read directly or from a linear regression.

Results, spectra, regression equations and correction data are kept in the internal memory, so the instrument starts quickly. The deuterium and tungsten lamps can be switched separately to extend their life. Via USB the NOVEL-900 connects to a PC; a thermal printer and the COLO spectrum PC software are available as options.

Standard delivery

  • NOVEL-900 UV/Vis double beam spectrophotometer with 8″ touch screen
  • Single cell holder, 10 mm
  • 4 × glass cuvette and 2 × quartz cuvette, 10 mm path length
  • Power cable, 2 fuses and operation manual

Optional: thermal printer, COLO spectrum PC software, cell holders 50 mm and 100 mm. The delivered configuration for a specific order is the one confirmed in the COLO.Science quotation.

Knowledge base

Spectral bandwidth, stray light, Beer–Lambert law and the choice of cuvettes are explained on COLO.Science — UV-Vis spectrophotometry and colour measurement, our knowledge base; how absorbance fits among other laboratory measurements is described in Measurement in laboratory science. The full data are in the NOVEL-900 technical specification (PDF).

Selection guide

  • Resolution and light throughput on one instrument: NOVEL-900 high resolution UV-Vis spectrophotometer — double beam, bandwidth 0.5 / 1 / 2 / 4 / 5 nm.
  • Double beam stability at an entry price: NOVEL-102S UV-Vis double beam spectrophotometer — 190–1100 nm, 2 nm, 8″ touch screen.
  • UV and Vis routine in series of samples: NOVEL-100S — split beam, automatic 8-cell holder.
  • Compact single beam UV/Vis at 2 nm: NOVEL4S — 190–1100 nm, 7″ touch screen.
  • Several bandwidths in one single-beam instrument: MAVRICA18 or LEGEND series — bandwidth from 0.5 to 5 nm.
  • Low stray light at a fixed 2 nm: NOVEL-800 double beam — 1600 lines/mm, ≤0.02 %T, baseline ≤±0.0008 A.
  • GLP data management or higher sensitivity: MAVRICA-T series for GLP/GMP data, or LEGEND-PMT double beam with PMT detector.

Configuration notice

This page is provided for orientation and product selection. Cell holders, cuvettes, printer, software and other options are confirmed with the official COLO.Science quotation.

Sales and support for international customers

COLO Lab ExpertsPolje ob Sotli 4, SI-3255 Buče, Slovenia
Phone: +386 70 713 437 · Email: sales@colo.si · Web: colo.si
We supply laboratories across Europe directly and through partners. B2B prices are quoted net, excluding VAT.

Need help choosing a spectrophotometer?

Considering the NOVEL-900? Send us your samples, the wavelengths and methods you use — we confirm whether a double beam instrument is the right choice and send a quotation with delivery time.

SKU: PRO3159 Category:
Spectral Bandwidth nm

, , ,

Spectrophotometers

, , , , , , ,

You may also like…

Request a Quote