COLO.Science · Spectroscopy & Color · UV/Vis spectrophotometers
NOVEL-100S split beam UV/Vis spectrophotometer — 190–1100 nm, spectral bandwidth 2 nm
The NOVEL-100S split beam UV/Vis spectrophotometer covers the ultraviolet, visible and near-infrared range from 190 to 1100 nm. Deuterium and tungsten-halogen lamps, a Czerny-Turner monochromator with a 1200 lines/mm grating and a spectral bandwidth of 2 nm give routine UV and visible measurements; the wavelength is set automatically and an automatic 8-position cell holder measures a series of samples in one run — all operated from the 8″ colour touch screen.
UV and visible range with automatic series measurement
Many laboratories need both ranges on one instrument: nucleic acids and proteins at 260/280 nm, UV methods in pharmacopoeias and water analysis, and colour reactions in the visible range. The NOVEL-100S is a split beam UV/Vis spectrophotometer for this mixed routine work: it scans the spectrum to find the absorption maximum, then measures blank, standards and samples in sequence in the automatic 8-cell holder.

Key characteristics
- Wavelength range 190–1100 nm, deuterium and tungsten-halogen lamps
- Spectral bandwidth 2 nm, split beam, Czerny-Turner monochromator, 1200 lines/mm grating, 160 mm focal length
- Wavelength accuracy ±0.3 nm, repeatability ≤0.1 nm, automatic wavelength setting
- Photometric accuracy ±0.002 A (0–0.5 A); stray light ≤0.03 %T at 220 nm and 360 nm; drift ≤0.0009 A/h
- Automatic 8-position cell holder for 10 mm cuvettes in standard delivery
- Full-spectrum scanning, peak/valley detection, kinetics, linear regression; 8″ colour touch screen and USB
Suitable for
- Life science and biochemistry: DNA, RNA and protein at 260/280 nm, enzyme kinetics
- Pharmaceutical quality control with UV and visible methods
- Water, wastewater and environmental laboratories
- Food, beverage and agricultural laboratories
- Clinical chemistry, teaching and research laboratories that need one instrument for UV and Vis
Why a split beam UV/Vis spectrophotometer with an 8-cell changer
In a split beam UV/Vis spectrophotometer part of the light is led to a reference detector, so lamp fluctuations are compensated and the reading stays stable during a series — in the UV as well as in the visible range. Combined with the automatic 8-cell holder, the NOVEL-100S measures a blank, standards and samples in one run without opening the lid, which saves time and removes handling errors in routine series.
For methods that only need the visible range, the NOVEL3S offers the same platform for 325–1100 nm; for a compact single beam instrument choose NOVEL4S.
Cell holders and sample handling
The NOVEL-100S is a UV/Vis spectrophotometer with 8-cell changer for 10 mm cuvettes in standard delivery; quartz cuvettes are used for the UV range. The sample compartment also accepts holders for 50 mm and 100 mm path length, micro cells, film holders, an integrating sphere and a Peltier / sipper system.
Models
NOVEL-100S — with wavelength scanning (this page). NOVEL-100 — the same instrument without scanning, for fixed-wavelength, quantitative and kinetic methods. All other specifications and accessories are identical.
NOVEL-100S split beam UV/Vis spectrophotometer — technical specifications
Optics and photometry
| Optical system | Split beam, Czerny-Turner monochromator |
| Grating · focal length | Holographic, 1200 lines/mm · 160 mm |
| Light source | Deuterium lamp and tungsten-halogen lamp |
| Wavelength range | 190–1100 nm |
| Spectral bandwidth | 2 nm |
| Wavelength accuracy | ±0.3 nm |
| Wavelength repeatability | ≤0.1 nm |
| Photometric accuracy | ±0.3 %T; ±0.002 A (0–0.5 A); ±0.004 A (0.5–1 A) |
| Photometric repeatability | ≤0.15 %T; 0.001 A (0–0.5 A); 0.002 A (0.5–1 A) |
| Photometric range | 0–200 %T; −0.301 to 4.000 A; 0–9999 C |
| Stray light | ≤0.03 %T at 220 nm (NaI) and 360 nm (NaNO₂) |
| Baseline flatness · drift | ≤±0.0015 A (200–1090 nm) · ≤0.0009 A/h |
| Noise | ≤0.15 %T at 100 %T · ≤0.1 %T at 0 %T |
| Detector | Silicon photocell |
Functions, data and general
| Measuring modes | T, A, C |
| Functions | Full-spectrum and detailed scanning, peak/valley, GOTO λ, multi-wavelength |
| Scanning speed | Fast · medium · slow |
| Quantitative analysis | Concentration direct reading; linear regression |
| Kinetics | Time-based kinetics |
| Cell holder | Automatic 8-position, 10 mm (standard) |
| Display | 8″ colour touch screen |
| Data output | USB, PC connection |
| Printer · PC software | Thermal printer · COLO spectrum software (options) |
| Conformity | CE |
| Power supply | AC 220 V ±22 V, 50 Hz ±1 Hz, 200 W |
| Packing size · gross weight | 700 × 580 × 500 mm · 32 kg |
Operation and data

The NOVEL-100S is operated from an 8 inch touch screen: wavelength, method and units are set on the screen; spectra, regression curves and kinetic plots are shown while the measurement runs. Zero and 100 %T are adjusted automatically, and concentration is read directly or from a linear regression.
Results, spectra, regression equations and correction data are kept in the internal memory, so the instrument starts quickly. The deuterium and tungsten lamps can be switched separately to extend their life. Via USB the NOVEL-100S connects to a PC for data processing and extended storage; a thermal printer and the COLO spectrum PC software are available as options.
Standard delivery
- NOVEL-100S split beam UV/Vis spectrophotometer with 8″ touch screen
- Automatic 8-position cell holder, 10 mm
- 4 × glass cuvette and 2 × quartz cuvette, 10 mm path length
- Power cable, 2 fuses and operation manual
Optional: thermal printer, COLO spectrum PC software, Wi-Fi UV lamp control, cell holders for 50 mm and 100 mm, single and micro cell holders, film holders, integrating sphere, flow cell, Peltier / sipper system and test-tube rack. The delivered configuration for a specific order is the one confirmed in the COLO.Science quotation.
Knowledge base
Spectral bandwidth, stray light, Beer–Lambert law and the choice of cuvettes are explained on COLO.Science — UV-Vis spectrophotometry and colour measurement, our knowledge base; how absorbance fits among other laboratory measurements is described in Measurement in laboratory science. The full data are in the NOVEL-100S technical specification (PDF).
Selection guide
- UV and Vis routine in series: NOVEL-100S split beam UV/Vis spectrophotometer — 190–1100 nm, automatic 8-cell holder, 8″ touch screen.
- Visible range only, in series: NOVEL3S — 325–1100 nm, split beam, automatic 8-cell holder.
- Compact single beam UV/Vis at 2 nm: NOVEL4S — 190–1100 nm, 7″ touch screen.
- Several bandwidths in one single-beam instrument: MAVRICA18 or LEGEND series — bandwidth from 0.5 to 5 nm.
- Long sequences, baseline stability, resolution checks: NOVEL-900 double beam with selectable 0.5–5 nm.
- GLP data management or higher sensitivity: MAVRICA-T series for GLP/GMP data, or LEGEND-PMT double beam with PMT detector.
Configuration notice
This page is provided for orientation and product selection. Cell holders, cuvettes, printer, software and other options are confirmed with the official COLO.Science quotation.
Sales and support for international customers
COLO Lab ExpertsPolje ob Sotli 4, SI-3255 Buče, Slovenia
Phone: +386 70 713 437 · Email: sales@colo.si · Web: colo.si
We supply laboratories across Europe directly and through partners. B2B prices are quoted net, excluding VAT.