Two Shops
One Shipment

NOVEL-102S UV/Vis Double Beam Spectrophotometer, 190–1100 nm, Bandwidth 2 nm

Availability:

Available on backorder


COLO.Science · UV-Vis double beam spectrophotometer

190–1100 nm · bandwidth 2 nm · double beam · D2 + W lamps · baseline ≤±0.002 A · 8″ touch screen

COLO.Science · Spectroscopy & Color · UV/Vis spectrophotometers

NOVEL-102S UV-Vis double beam spectrophotometer — 190–1100 nm, spectral bandwidth 2 nm

The NOVEL-102S UV-Vis double beam spectrophotometer measures every sample against a reference beam across 190–1100 nm. Deuterium and tungsten lamps, a Czerny-Turner monochromator with a 1200 lines/mm grating and a spectral bandwidth of 2 nm give stable UV and visible readings during long scans and kinetics; the wavelength is set automatically and everything is operated from the 8″ colour touch screen.

Double beam measurement for scans, kinetics and low absorbance

In a single beam instrument a change of lamp intensity after the blank appears directly in the result. The NOVEL-102S splits the light into a sample and a reference beam and measures both, so the baseline stays flat (≤±0.002 A) and drift stays below 0.0009 A/h. That matters for full-spectrum scans, long kinetic runs and samples with low absorbance — the typical work of a UV-Vis double beam spectrophotometer.

NOVEL-102S UV-Vis double beam spectrophotometer with 8 inch touch screen

Key characteristics

  • Double beam optics, Czerny-Turner monochromator, 1200 lines/mm grating, 160 mm focal length
  • Wavelength range 190–1100 nm, spectral bandwidth 2 nm, deuterium and tungsten lamps
  • Wavelength accuracy ±0.3 nm, repeatability ≤0.1 nm, automatic wavelength setting
  • Photometric accuracy ±0.002 A (0–0.5 A); stray light ≤0.03 %T; baseline ≤±0.002 A; drift ≤0.0009 A/h
  • Full-spectrum scanning, peak/valley detection, GOTO λ, multi-wavelength, kinetics, linear regression
  • 8″ colour touch screen, internal memory and USB; single 10 mm cell holder, 2 quartz and 4 glass cuvettes

Suitable for

  • Life science and biochemistry: DNA, RNA and protein at 260/280 nm, enzyme kinetics
  • Pharmaceutical quality control with UV and visible methods
  • Water, wastewater and environmental laboratories
  • Food, beverage and agricultural laboratories
  • Clinical chemistry, teaching and research laboratories that need one instrument for UV and Vis

Why a UV-Vis double beam spectrophotometer

A UV-Vis double beam spectrophotometer compares the sample with the reference at every point of the measurement. Lamp warm-up, ageing and mains fluctuations are compensated, so a spectrum recorded over minutes or a kinetic curve over an hour is not distorted by the instrument. The NOVEL-102S brings this to routine laboratories at the price level of the NOVEL platform.

For series of samples with an automatic 8-cell holder choose the NOVEL-100S; for selectable bandwidth from 0.5 to 5 nm and the lowest stray light choose the NOVEL-900.

Cell holders and sample handling

The NOVEL-102S measures 10 mm cuvettes in a single cell holder in the sample beam; quartz cuvettes are used for the UV range, glass cuvettes for the visible range. 2 quartz and 4 glass cuvettes are included.

Quartz and glass cuvettes — NOVEL-102S
Quartz and glass cuvettes2 quartz and 4 glass cuvettes, 10 mm, in standard delivery.
Standard
Single cell holder 10 mm — NOVEL-102S
Single cell holder 10 mmFixed position in the sample beam — standard.
Standard

NOVEL-102S UV-Vis double beam spectrophotometer — technical specifications

Optics and photometry

Optical system Double beam, Czerny-Turner monochromator
Grating · focal length Holographic, 1200 lines/mm · 160 mm
Light source Deuterium lamp and tungsten-halogen lamp
Wavelength range 190–1100 nm
Spectral bandwidth 2 nm
Wavelength accuracy ±0.3 nm
Wavelength repeatability ≤0.1 nm
Photometric accuracy ±0.3 %T; ±0.002 A (0–0.5 A); ±0.004 A (0.5–1 A)
Photometric repeatability ≤0.15 %T; 0.001 A (0–0.5 A); 0.002 A (0.5–1 A)
Photometric range 0–200 %T; −0.301 to 4.000 A; 0–9999 C
Stray light ≤0.03 %T at 220 nm (NaI) and 360 nm (NaNO₂)
Baseline flatness · drift ≤±0.002 A (200–1090 nm) · ≤0.0009 A/h
Noise ≤0.15 %T at 100 %T · ≤0.1 %T at 0 %T
Detector Silicon photocell

Functions, data and general

Measuring modes T, A, C
Functions Full-spectrum and detailed scanning, peak/valley, GOTO λ, multi-wavelength
Scanning speed Fast · medium · slow
Quantitative analysis Concentration direct reading; linear regression
Kinetics Time-based kinetics
Cell holder Single cell holder, 10 mm (standard)
Display 8″ colour touch screen
Data output USB, PC connection
Printer · PC software Thermal printer · COLO spectrum software (options)
Conformity CE
Power supply AC 220 V ±22 V, 50 Hz ±1 Hz, 200 W
Packing size · gross weight 700 × 580 × 500 mm · 32 kg

Operation and data

NOVEL-102S UV-Vis double beam spectrophotometer

The NOVEL-102S is operated from an 8 inch touch screen: wavelength, method and units are set on the screen; spectra, regression curves and kinetic plots are shown while the measurement runs. Zero and 100 %T are adjusted automatically, and concentration is read directly or from a linear regression.

Results, spectra, regression equations and correction data are kept in the internal memory, so the instrument starts quickly. The deuterium and tungsten lamps can be switched separately to extend their life. Via USB the NOVEL-102S connects to a PC; a thermal printer and the COLO spectrum PC software are available as options.

Standard delivery

  • NOVEL-102S UV/Vis double beam spectrophotometer with 8″ touch screen
  • Single cell holder, 10 mm
  • 4 × glass cuvette and 2 × quartz cuvette, 10 mm path length
  • Power cable, 2 fuses and operation manual

Optional: thermal printer and COLO spectrum PC software. The delivered configuration for a specific order is the one confirmed in the COLO.Science quotation.

Knowledge base

Spectral bandwidth, stray light, Beer–Lambert law and the choice of cuvettes are explained on COLO.Science — UV-Vis spectrophotometry and colour measurement, our knowledge base; how absorbance fits among other laboratory measurements is described in Measurement in laboratory science. The full data are in the NOVEL-102S technical specification (PDF).

Selection guide

  • Double beam stability at an entry price: NOVEL-102S UV-Vis double beam spectrophotometer — 190–1100 nm, 2 nm, 8″ touch screen.
  • UV and Vis routine in series of samples: NOVEL-100S — split beam, automatic 8-cell holder.
  • Compact single beam UV/Vis at 2 nm: NOVEL4S — 190–1100 nm, 7″ touch screen.
  • Several bandwidths in one single-beam instrument: MAVRICA18 or LEGEND series — bandwidth from 0.5 to 5 nm.
  • Long sequences, baseline stability, resolution checks: NOVEL-900 double beam with selectable 0.5–5 nm.
  • GLP data management or higher sensitivity: MAVRICA-T series for GLP/GMP data, or LEGEND-PMT double beam with PMT detector.

Configuration notice

This page is provided for orientation and product selection. Cell holders, cuvettes, printer, software and other options are confirmed with the official COLO.Science quotation.

Sales and support for international customers

COLO Lab ExpertsPolje ob Sotli 4, SI-3255 Buče, Slovenia
Phone: +386 70 713 437 · Email: sales@colo.si · Web: colo.si
We supply laboratories across Europe directly and through partners. B2B prices are quoted net, excluding VAT.

Need help choosing a spectrophotometer?

Considering the NOVEL-102S? Send us your samples, the wavelengths and methods you use — we confirm whether a double beam instrument is the right choice and send a quotation with delivery time.

SKU: PRO3558 Category:
Spectral Bandwidth nm

, , ,

Spectrophotometers

, , , , , , ,

You may also like…

Request a Quote