COLO.SCIENCE — NEUTRAL HIGH-CAPACITY CENTRIFUGATION
One centrifuge platform for bottles, tubes, microplates and blood collection workflows
The LACE56N platform is intended for laboratories that need high sample throughput and broad vessel compatibility without active refrigeration. Its 5-inch touch screen provides access to speed, RCF, time and ramp settings, while automatic rotor identification supports safer configuration of the selected rotor family.
Rotor performance is configuration dependent. The centrifuge host, rotor, buckets and adapters should therefore be selected as one working system according to vessel geometry, working volume, target RCF, biosafety expectations and the laboratory SOP.
Key performance features
- 6000 rpm and 6321 × g maximum performance, rotor dependent.
- 4 × 750 ml maximum capacity with a compatible swing-out rotor.
- 5-inch touch screen with clear operating parameters.
- Automatic rotor identification to support correct rotor selection.
- 10 acceleration and 10 deceleration levels for controlled start and stop profiles.
- Quick-spin, timed startup, 10-stage procedures and parameter adjustment during operation.
- Electronic door lock, imbalance protection and three-level rubber damping.
Suitable laboratory workflows
- Routine high-capacity sample separation.
- Clinical and blood collection tube workflows.
- Cell culture separation and biopharming.
- RIA and molecular chemistry applications.
- Large-volume bottles and conical tube preparation.
- Microplate processing with the matching holder rack.
- Selected biosafety configurations with verified airtight components.
LACE56N high capacity centrifuge with 4 × 750 ml rotor configuration
Large chamber with high-capacity swing-out rotor
The open-unit view illustrates the LACE56N chamber with a representative 4 × 750 ml rotor configuration. Final bottles, buckets and adapters must match the ordered rotor system.
Lightweight NCP fixed-rotor configurations
PRO6945 and PRO7063 are presented as NCP fixed-rotor configurations. The composite architecture is intended to combine lower handling weight, corrosion resistance and validated rotor performance.
Nano-ceramic coated chamber concept
The coated chamber concept is highlighted for corrosion resistance, easier routine cleaning and additional long-term protection in demanding laboratory centrifugation environments.
TECHNICAL SPECIFICATIONS — LACE56N HIGH CAPACITY HIGH SPEED CENTRIFUGE
| Product | LACE56N high capacity high speed centrifuge |
| Product number / SKU | PRO6932 |
| Model type | Neutral / non-refrigerated high-capacity laboratory centrifuge |
| Structure | Desktop / benchtop |
| Maximum speed | 6000 rpm, rotor dependent |
| Maximum RCF | 6321 × g, rotor dependent |
| Maximum capacity | 4 × 750 ml with compatible swing-out rotor |
| Control interface | 5-inch touch screen |
| Rotor identification | Automatic |
| Acceleration / deceleration | 10 adjustable levels |
| Procedure support | 10-stage procedure; quick-spin, timed start and parameter changes during operation |
| Timer | 1 s–99 min 59 s / 1 min–99 h 99 min |
| Speed accuracy | ±10 rpm/min, as listed in the current technical data |
| Rotor / adapter range | 0.2 ml tubes to 750 ml tubes or bottles; microplates and selected blood-tube workflows |
| Chamber technology | Nano-ceramic coated chamber concept |
| Safety | Electronic door lock, imbalance protection, full-steel inner protection and 3-level rubber damping |
| Power range | AC 220 ±22 V, 50 Hz, 16 A |
| Power consumption | 800 W |
| Instrument size | 55 × 47 × 35 cm |
| External / packing dimension | 760 × 720 × 540 mm |
| Net weight | 50 kg |
| Certification | CE, ISO |
Maximum speed, RCF and capacity cannot normally be achieved simultaneously with every rotor. The valid operating limit is determined by the lowest-rated component in the centrifuge, rotor, bucket, adapter and sample-vessel system.
ROTOR, BUCKET AND ADAPTER CONFIGURATION
Compatible rotor families for LACE56N
The LACE56N high capacity high speed centrifuge is supplied as a configurable platform. Select the rotor first according to vessel format and required throughput, then confirm the compatible bucket and adapter set. Rotor availability and included components must be stated in the official quotation.
High-capacity laboratory centrifuge with application-specific rotor selection
The LACE56N high capacity high speed centrifuge can be configured with fixed-angle, large-volume swing-out, blood collection tube and microplate rotors. Selecting the correct rotor image and SKU helps laboratories compare 12 × 10 ml, 4 × 500 ml, 4 × 750 ml, 96-place and 120-place configurations before the final quotation is prepared.
NCP
12 × 10 ml fixed rotor, rounded
6000 rpm · 6321 × g
Compatible adapters / formats
- Direct rotor configuration
4 × 250 ml swing-out rotor, square cup
4000 rpm · 3040 × g
Compatible adapters / formats
- PRO6947 · 4 × 4 × 50 ml, conical bottom
- PRO6948 · 4 × 8 × 15 ml, conical bottom
- PRO6949 · 4 × 8 × 10 ml, round bottom
- PRO6950 · 4 × 14 × 5 ml, round bottom
- PRO6951 · 4 × 14 × 1.5 / 2 ml
- PRO6952 · 4 × 10 × 10 ml blood collection tubes
- PRO6953 · 4 × 18 × 5 ml blood collection tubes
4 × 300 ml swing-out rotor
4000 rpm · 3040 × g
Compatible adapters / formats
- For 250 ml conical-bottom bottle workflow
- PRO6955 · selectable 50–300 ml adapter configuration
BioSafe
4 × 500 ml biosafety swing-out rotor, rounded
4000 rpm · 3500 × g
Compatible adapters / formats
- PRO6958 · 4 × 250 ml, round bottom
- PRO6959 · 4 × 4 × 50 ml, conical bottom
- PRO6960 · 4 × 100 ml, round bottom
- PRO6961 · 4 × 9 × 15 ml, conical bottom
- PRO6962 · 4 × 9 × 10 ml, round bottom
- PRO6963 · 4 × 14 × 5 ml
- PRO6964 · 4 × 14 × 1.5 / 2 ml
- PRO6965 · 4 × 12 × 10 ml cap-removing blood tubes
- PRO6966 · 4 × 14 × 2 / 5 / 7 ml cap-removing blood tubes
4 × 500 ml swing-out rotor, rounded
4000 rpm · 3500 × g
Compatible adapters / formats
- PRO6958 · 4 × 250 ml, round bottom
- PRO6959 · 4 × 4 × 50 ml, conical bottom
- PRO6960 · 4 × 100 ml, round bottom
- PRO6961 · 4 × 9 × 15 ml, conical bottom
- PRO6962 · 4 × 9 × 10 ml, round bottom
- PRO6963 · 4 × 14 × 5 ml
- PRO6964 · 4 × 14 × 1.5 / 2 ml
- PRO6965 / PRO6966 · blood-tube configurations
4 × 750 ml swing-out rotor, rounded
4000 rpm · 3500 × g
Compatible adapters / formats
- PRO6968 · 4 × 500 ml, conical / round bottom
- PRO6969 · 4 × 250 ml, conical / round bottom
- PRO6970 · 4 × 3 × 100 ml
- PRO6971 · 4 × 7 × 50 ml, conical
- PRO6972 · 4 × 14 × 15 ml, conical
- PRO6973 · 4 × 14 × 10 ml, round bottom
- PRO6974 · 4 × 21 × 5 / 6 ml
- PRO6975 · 4 × 26 × 1.5 / 2 ml
- PRO6976 / PRO6977 · cap-removing blood-tube configurations
4 × 750 ml swing-out rotor, square
4000 rpm · 3580 × g
Compatible adapters / formats
- PRO6979 · 4 × 500 ml, round bottom
- PRO6980 · 4 × 250 ml, round bottom
- PRO6981 · 4 × 3 × 100 ml
- PRO6982 · 4 × 7 × 50 ml, conical
- PRO6983 · 4 × 14 × 15 ml, conical
- PRO6984 · 4 × 14 × 10 ml, round bottom
- PRO6985 · 4 × 24 × 5 / 6 ml
- PRO6986 · 4 × 30 × 1.5 / 2 ml
- PRO6987 / PRO6988 · cap-removing blood-tube configurations
Microplate swing-out holder rack · 4 × 4 × 96
4000 rpm · 3040 × g
Compatible adapters / formats
- Direct microplate configuration
96 × 5 / 7 ml blood collection tube swing-out rotor
4000 rpm · 3000 × g
Compatible adapters / formats
- Direct rotor configuration
120 × 5 / 7 ml blood collection tube swing-out rotor
4000 rpm · 3500 × g
Compatible adapters / formats
- Direct rotor configuration
NCP
12 × 10 ml angle rotor
6000 rpm · 6321 × g
Compatible adapters / formats
- Direct rotor configuration
Adapter and vessel compatibility must be checked against exact tube or bottle dimensions, bottom geometry, cap type, maximum vessel speed / RCF, balancing requirements and laboratory SOP.
Control, workflow and safety support
Automatic rotor identification
Rotor recognition helps reduce incorrect profile selection and supports safer use of a centrifuge platform with many rotor families.
Controlled acceleration and braking
Ten acceleration and deceleration levels allow the run profile to be adapted to sensitive samples and help limit secondary mixing during braking.
Multi-stage procedures
Ten-stage procedures, quick-spin operation, timed startup and parameter changes during operation support repeatable daily protocols.
Mechanical and lid protection
Electronic door locking, imbalance protection, a full-steel inner protection structure and three-level rubber damping support controlled operation.
Applications and laboratory value
Routine high-capacity separation
A practical solution for laboratories processing large sample batches or larger bottles without requiring active refrigeration.
Clinical and blood tube workflows
Dedicated 96-place and 120-place blood collection tube rotors support higher-throughput clinical sample preparation.
Cell culture and biopharming
Large-volume swing-out configurations support cell culture separation, biological preparation and related research workflows.
Microplate processing
The PRO6989 holder rack extends the platform to multi-well plate formats for suitable laboratory protocols.
CONFIGURATION GUIDE
How to select the correct LACE56N rotor and adapter configuration
Begin with the actual sample vessel rather than the centrifuge maximum. Confirm nominal volume, working fill volume, outside diameter, length, bottom shape, cap type and the vessel manufacturer’s permitted speed or RCF. Then select the rotor family, bucket and adapter that provide the required capacity and operating force.
For blood collection tubes, define tube volume, cap-removal requirement and expected daily throughput. For bottles, confirm whether the bottom is conical or round and whether a dedicated insert is required. For microplates, confirm plate type, overall height, loading symmetry and the accepted plate centrifugation limit.
The LACE56N high capacity high speed centrifuge is the non-refrigerated model. Temperature-sensitive workflows should be evaluated separately and may require a refrigerated centrifuge platform.
LABORATORY CENTRIFUGE CATALOGUE
Compare centrifuge platforms and rotor capacities
Use the catalogue to compare high-capacity, refrigerated, high-speed and compact centrifuge platforms by speed, RCF, capacity and supported sample format.
COLO.SCIENCE KNOWLEDGE AND SUPPORT
Technical guidance for centrifuge configuration
COLO.Science supports rotor and adapter selection according to vessel format, sample volume, target RCF, throughput, balance requirements and biosafety expectations.
Configuration and specification notice
The host centrifuge, rotor, buckets, adapters and sample vessels form one operating system. The official quotation and order confirmation must define the centrifuge SKU, rotor SKU, included buckets, adapter set, vessel dimensions, electrical configuration, safety documentation and final operating limits. Website content supports product selection and does not replace the binding quotation, manufacturer manual or rotor certificate. Specifications may change without notice.