COLO.SCIENCE — UNIVERSAL NON-REFRIGERATED TABLE-TOP CENTRIFUGE
Flexible rotor selection for routine laboratory separation
The LACE32 laboratory centrifuge is designed for laboratories that need one bench-top centrifuge for several vessel formats and routine workflows. The available rotor family includes swing-out configurations for clinical tubes and larger vessels, angle rotors for selected tube formats and a microplate option for multiwell plate preparation.
A 5-inch high-precision touch screen displays speed, RCF, time and rotor or method parameters. Ten acceleration and deceleration levels, soft start and stop support, electronic lid protection and automatic imbalance detection help operators run repeatable daily methods.
Key features
- Up to 6000 rpm and 6321 × g, rotor dependent.
- Maximum listed capacity of 4 × 250 ml.
- Nine compatible rotor configurations in the current technical specification.
- Swing-out, angle and microplate rotor choices.
- 5-inch high-precision touch screen.
- Ten adjustable acceleration and deceleration levels.
- Maintenance-free brushless motor.
- Electronic lid interlock and automatic imbalance stop.
Suitable for
- Serum, plasma, blood and urine sample separation.
- Cell harvesting, washing and clarification.
- Routine biopharmaceutical sample preparation.
- Research, teaching and QA/QC laboratories.
- General liquid and suspension separation.
- Microplate preparation with the compatible rotor.
SELECTION NOTE — LACE32 CONFIGURATION
Choose the rotor by vessel format, working volume and target RCF
The final LACE32 laboratory centrifuge configuration should begin with the sample vessel, not only the maximum centrifuge speed. Confirm tube or plate dimensions, working volume, number of samples per run, required RCF and the maximum permitted speed of the vessel.
The operating limit is always set by the lowest permitted value among the centrifuge, rotor, bucket, adaptor and sample vessel. Rotor, bucket and adaptor compatibility should therefore be confirmed in the quotation and order documentation.
LACE32 laboratory centrifuge with configurable rotor platform

One centrifuge body, multiple routine workflows
The rotor portfolio covers clinical tubes, larger vessels and microplates. This makes LACE32 useful where one laboratory platform must support several sample preparation methods without moving to a floor-standing centrifuge.
The base unit, included rotor, buckets and adaptors must be defined in the official offer. The current technical specification presents the rotor family as configurable according to order.
TECHNICAL SPECIFICATIONS — LACE32 LABORATORY CENTRIFUGE
| Product | LACE32 laboratory centrifuge |
| Product SKU | PRO5042 |
| Type | Universal low-speed, non-refrigerated table-top centrifuge |
| Maximum speed | Up to 6000 rpm, rotor dependent |
| Maximum RCF | Up to 6321 × g, rotor dependent |
| Maximum listed capacity | 4 × 250 ml with compatible swing-out rotor |
| Display | 5-inch high-precision touch screen |
| Displayed / set values | Speed, RCF, time and rotor / method parameters |
| Timer | 0–99 min; additional operating modes as configured |
| RPM / RCF handling | RPM–RCF conversion according to selected rotor |
| Drive | Maintenance-free brushless motor |
| Acceleration / deceleration | 10 adjustable levels; soft start / stop support |
| Operating modes | Timed, jog, gradient and time-difference centrifugation |
| Lid protection | Electronic safety interlock; lid remains locked during rotation |
| Imbalance protection | Automatic detection and stop |
| Body / shield | T45 cold-rolled steel body with full-steel inner shield |
| Chamber | 304 stainless steel, deep-drawn, nano-ceramic anti-corrosion coating |
| Shock absorption | Three-stage rubber damping system |
| Quality statement | Source description references ISO 9001 quality-system manufacturing |
Performance is rotor dependent. Exact dimensions, weight, electrical rating, rated power, noise, included rotor, buckets and adaptors should be confirmed in the binding quotation, order confirmation and manufacturer documentation.
Compatible rotor configurations for LACE32

Rotor SKU: PRO2879
48 × 5 ml Swing-out Rotor
Listed: 6000 rpm / 6321 × g
Cross: PRO6925

Rotor SKU: PRO2887
32 × 10 ml Swing-out Rotor
Name listing: 6000 rpm / 6321 × g
Legacy note: 4000 rpm / 2880 × g

Rotor SKU: PRO3314
8 × 50 ml Angle Rotor
Name listing: 6000 rpm / 6321 × g
Legacy note: 4000 rpm / 2250 × g

Rotor SKU: PRO3376
2 × 2 × 96-well Microplate Rotor
Listed: 6000 rpm / 6321 × g
Cross: PRO6925

Rotor SKU: PRO5527
32 × 15 ml Swing Rotor
Listed: 6000 rpm / 6321 × g
Cross: PRO6925

Rotor SKU: PRO5529
72 × 5/7 ml Swing Rotor
Listed: 6000 rpm / 6321 × g
Cross: PRO6925

Rotor SKU: PRO5530
4 × 250 ml Swing Rotor, Flat Bottom
Name listing: 6000 rpm / 6321 × g
Legacy note: 4000 rpm / 2840 × g

Rotor SKU: PRO7063
12 × 10 ml Angle Rotor
Listed: 6000 rpm / 6321 × g
Cross: PRO6925 / PRO3051

Rotor SKU: PRO6946
4 × 250 ml Swing-out Rotor, Square Cup
Listed: 6000 rpm / 6321 × g
Cross: PRO6932 / PRO6925
Rotor data note: the supplied source records contain conflicting speed / RCF descriptions for PRO2887 and PRO3314 and reuse several image links. The exact rotor identity, photograph, maximum permitted speed, RCF, bucket and adaptor combination must be confirmed before quotation or operation.
ADAPTORS, BUCKETS AND ORDERING SUPPORT
Adapt LACE32 to additional tube formats
Selected swing-out rotors can be configured with buckets and adaptors for additional tube formats. Exact vessel dimensions, nominal volume, cap type and maximum permitted vessel speed should be checked before ordering.
| Rotor SKU | Rotor format | Listed adaptor options |
|---|---|---|
| PRO5530 | 4 × 250 ml, flat bottom | 4 × 100 ml; 4 × 2 × 50 ml; 4 × 3 × 15 ml |
| PRO6946 | 4 × 250 ml, square cup | 50, 15, 10, 5 and 1.5 ml tubes; blood tubes |
Operation, protection and repeatability
The LACE32 laboratory centrifuge combines touch operation, controlled ramp profiles and layered safety functions for repeatable routine separation.
Touch-screen control
Speed, RCF, time and rotor or method parameters are displayed clearly and can be modified according to the selected operating mode.
Soft start and stop
Ten acceleration and deceleration levels help adapt the run profile and limit post-separation remixing in sensitive routine methods.
Layered protection
Electronic lid interlock, full-steel inner shielding, automatic imbalance detection and stop support safer daily operation.
Corrosion-resistant chamber
The deep-drawn 304 stainless-steel chamber includes a nano-ceramic anti-corrosion coating for routine laboratory use.
LABORATORY CENTRIFUGES CATALOG
Compare centrifuge types, rotor capacities and applications
Use the centrifuge catalog to compare table-top, clinical, refrigerated, mini and special centrifuge platforms before selecting the final rotor configuration.
COLO.SCIENCE KNOWLEDGE AND SUPPORT
Practical support for rotor and vessel selection
COLO.Science supports centrifuge selection according to vessel format, sample volume, required RCF, rotor capacity, balancing requirements and laboratory SOP.
Applications and laboratory value
As a universal low-speed platform, the LACE32 laboratory centrifuge can be configured for clinical tubes, research vessels and multiwell plates.
Clinical laboratories
Swing-out rotor choices support routine preparation of serum, plasma, blood and urine samples in clinical and veterinary workflows.
Research and cell workflows
The configurable rotor family supports cell harvesting, washing, clarification and general liquid or suspension separation.
Biopharmaceutical and QA/QC
Repeatable touch-screen settings and controlled ramp profiles support routine preparation and phase separation methods.
Microplate preparation
The compatible 2 × 2 × 96-well microplate rotor extends the platform to selected multiwell plate preparation procedures.
Configuration and specification notice
The LACE32 laboratory centrifuge can be supplied with different rotor, bucket, adaptor and documentation configurations. The official quotation and order confirmation define the final scope of delivery, included versus optional items, permitted speed and RCF, electrical data, dimensions, weight and safety documentation. Website content supports product selection and does not replace the binding manufacturer manual or rotor certificate. Specifications may change without notice.