High Capacity & High Speed Centrifuge Series · Ambient and Refrigerated Models · up to 4 × 750 ml
COLO.Science LACE56 Series is a high-capacity, high-speed desktop centrifuge platform designed for laboratories that require flexible rotor configuration, large sample volume and routine-to-advanced centrifugation workflows. The series includes the LACE56 normal-temperature centrifuge and the LACE56R refrigerated centrifuge, supporting swing-out rotors up to 4 × 750 ml, microplate holders, blood collection tube rotors and multiple adapter configurations.
Document type: Technical specification · beta version
Product series: LACE56 high capacity & high speed centrifuge series
Models: PRO6932 LACE56 / PRO6992 LACE56R
Format: A4 landscape · print-ready HTML draft
Status: Beta draft · rotor and adapter data to be verified before final release
Beta note: this document intentionally keeps adapter image areas as empty placeholders. Final adapter photography, final rotor matching and refrigerated-model physical data should be confirmed before catalogue publication or formal quotation.
LACE56 · high capacity high speed centrifuge · normal-temperature model · PRO6932
LACE56R · high capacity high speed refrigerated centrifuge · PRO6992
LACE56 Series · technical specification
High-capacity desktop centrifuge platform with ambient and refrigerated model variants
max. 6000 rpmmax. 6321 × g4 × 750 ml max capacityautomatic rotor recognitionelectronic door lock— Designed for RIA, molecular chemistry, biopharming, cell culture separation, clinical medicine and routine laboratory centrifugation.
📋 Model range · LACE56 with and without refrigeration
High-capacity routine centrifugation with broad rotor and adapter selection
PRO6992 · LACE56R
Refrigerated high-capacity high-speed centrifuge
Temperature-controlled centrifugation for samples requiring cooling protection
Key performance data
Parameter
Specification
Maximum speed
6000 rpm
Maximum RCF
6321 × g
Maximum capacity
4 × 750 ml
Speed accuracy
±10 rpm / min
Time setting
1 s – 99 min 59 s / 1 min – 99 h 99 min
Certification
CE, ISO
⚙️ Main technical specification
Parameter
Specification
Model No.
LACE56 Series
Classification
Medical centrifuge / laboratory centrifuge
Structure
Desktop
Material
Steel
Maximum speed
6000 rpm
Maximum RCF
6321 × g
Maximum capacity
4 × 750 ml
Power range
AC 220 ±22 V, 50 Hz, 16 A
Parameter
Specification
Power consumption
800 W (confirm per LACE56 / LACE56R)
Weight
50 kg (base data supplied; refrigerated model to verify)
Instrument size
55 × 47 × 35 cm
External / packing dimension
760 × 720 × 540 mm (verify classification)
Transport package
Carton packing
Trademark
COLO.Science
HS Code
8421199090
Document note
Beta technical sheet · data to be checked before final publication
Max. capacity4 × 750 ml
Max. speed6000 rpm
Max. RCF6321 × g
Model versionsLACE56 / LACE56R
Refrigerated-model details are shown only where source data is available. Temperature range, compressor specification, refrigerated-model dimensions and final weight should be added in the final catalogue version.
Page 2 / 8
LACE56 Series · Function and Safety Overview
High capacity centrifugation · Rotor recognition · User safety functions
5-inch touch screen: supports clear parameter setting and easy operation.
Accurate parameter control: centrifugal force can be set to 1 × g, speed can be set to 1 rpm and time can be set to 1 second.
Live parameter display: the large screen displays speed, centrifugal force, time, temperature, acceleration, deceleration and related operating parameters.
Parameter change during operation: parameters can be changed during operation without stopping the centrifuge.
Acceleration, deceleration and workflow
10-level acceleration and deceleration: acceleration and braking can be controlled to help avoid secondary sample mixing during reduction.
Multi-stage procedure: the centrifuge procedure can be set in 10 stages.
Instant centrifugation: quick-spin operation can be used for short workflows.
Timed startup: timed startup function is supported for planned operation.
Speed up / down setting: speed increase and reduction time can be freely set according to the protocol.
Safety and protection
3-level rubber damping: supports good automatic balancing performance and helps reduce vibration.
Imbalance switch protection: imbalance protection is included to support operator safety.
Electronic door lock: the machine adopts an electronic door lock for safe operation.
All-steel inner cavity protection sleeve: the chamber protection design supports operator and instrument safety.
One-time moulding machine structure: designed to improve structural protection and user safety.
Refrigerated operation · LACE56R
Rapid cooling: solenoid valve control is used for rapid cooling function.
Cooling note: source data indicates temperature reduction from 25 °C to 4 °C within 8; final unit should be confirmed before publication, assumed as minutes in this beta draft.
Temperature display: temperature is displayed among the operating parameters on the control screen.
Recommended final data to add: temperature range, cooling time unit, refrigeration system, compressor type, refrigerated-model power consumption and operating ambient conditions.
🧬 Application scope
Clinical and routine laboratories
Blood collection tube workflows
Routine sample separation
Clinical medicine applications
Multi-tube sample preparation
Research and biopharming
Cell culture isolation
Molecular chemistry work
RIA-related workflows
Temperature-sensitive samples with LACE56R
Biosafety configurations
Biosafety centrifuge options
Biosafety airtight rotors
Biosafety airtight adapters
Suitable for hazardous sample centrifugation when configured accordingly
Biosafety statement is configuration-dependent. For dangerous samples such as infectious viruses, infectious bacteria or radioactive samples, final rotor, adapter and sealing configuration must be checked before use.
Page 3 / 8
LACE56 Series · Visual Rotor Overview
Available images inserted · Missing adapter visuals reserved as placeholders
🖼️ Main visuals and rotor examples
LACE56
Centrifuge with 4 × 750 ml rotorHigh-capacity configuration
Chamber
Chamber with rotor installed4 × 750 ml visual reference
PRO6967
Swing-out rotor · 4 × 750 ml · rounded6000 rpm · 6321 × g
PRO6957
Swing-out rotor · 4 × 500 ml · rounded6000 rpm · 6321 × g
12 × 10 ml rotor · NCP / angle rotor visualCode to verify against PRO6945 line
Adapter image placeholder
ADR
Adapter visuals reserved for later updateEmpty by design in beta version
Biosafety option placeholder
BioSafe
Biosafety rotor / adapter configurationFinal accessory visuals to be added
Visual reference only. Rotor names, final catalogue codes and adapter compatibility should be checked during the next refinement phase.
Page 4 / 8
LACE56 Series · Rotor Configuration Guide
Rotor → adapter → sample format · Beta configuration layout
Rotor configuration overview
Each rotor is shown with its compatible adapter family · adapter images reserved as placeholders
How to read this section: first select the rotor body according to the main sample format and capacity. Then select the required adapter set. Adapter image positions are intentionally left empty in this beta version and can be filled later after exact adapter photos are matched with the SKU codes.
PRO6945
Rotor 12 × 10 ml · rounded
6000 rpm · 6321 × g
Direct rotor configuration
12 × 10 ml
Rounded rotor for 12 × 10 ml tube configuration.
Direct rotor use
Image note
Supplied image filename uses PRO6939; table line uses PRO6945.
Code to verify
Adapter set
No separate adapter family listed for this rotor in the supplied data.
Swing-out rotor 96 × 5 / 7 ml for blood collection tubes.
Image to add
Blood tube rotor image placeholder
PRO6991 · Blood collection tube rotor
Swing-out rotor 120 × 5 / 7 ml for blood collection tubes.
Image to add
Manufacturer and configuration support
COLO Lab Experts
Polje ob Sotli 4, SI-3255, Slovenia
Selection guidance: LACE56 Series should be configured according to tube format, bottle format, sample type, required temperature control, biosafety level and preferred rotor family. For final quotation, confirm whether the user needs LACE56 normal-temperature model or LACE56R refrigerated model, and match each rotor with the correct adapter set.
COLO.Science · high-capacity centrifugation support
Request a rotor configuration or quotation for LACE56 / LACE56R
Share the tube format, bottle volume, microplate workflow, sample type, cooling requirement and biosafety expectation. COLO.Science can help define the correct centrifuge model, rotor family and adapter set for the intended laboratory workflow.
Beta document control note: each rotor family is visually separated from the next one, and each adapter belongs directly under its rotor. Adapter image spaces are intentionally empty in this beta version so that final photos can be added later without changing the layout logic. Verify refrigerated-model technical data, exact adapter-code mapping, duplicate code PRO6969, rotor code PRO6939 / PRO6945 mismatch and all missing adapter images before final release.