COLO.Science LACE56 Series is a high-capacity, high-speed desktop centrifuge platform designed for laboratories that require flexible rotor configuration, large sample volume and routine-to-advanced centrifugation workflows. The series includes the LACE56 normal-temperature centrifuge and the LACE56R refrigerated centrifuge, supporting swing-out rotors up to 4 × 750 ml, microplate holders, blood collection tube rotors and multiple adapter configurations.
6000 rpm 6321 × g 4 × 750 ml Ambient / Refrigerated 5-inch Touch Screen Auto Rotor ID 10-stage Program Biosafety Options
Document type: Technical specification · beta version
Product series: LACE56 high capacity & high speed centrifuge series
Models: PRO6932 LACE56 / PRO6992 LACE56R
Format: A4 landscape · print-ready HTML draft
Status: Beta draft · rotor and adapter data to be verified before final release
Beta note: this document intentionally keeps adapter image areas as empty placeholders. Final adapter photography, final rotor matching and refrigerated-model physical data should be confirmed before catalogue publication or formal quotation.
COLO.Science LACE56 high capacity high speed centrifuge main unit
LACE56 · high capacity high speed centrifuge · normal-temperature model · PRO6932
COLO.Science LACE56R refrigerated high capacity high speed centrifuge
LACE56R · high capacity high speed refrigerated centrifuge · PRO6992
Series LACE56
Address HQ Polje ob Sotli 4
SI-3255, Slovenia
Page 1 / 8
COLO.Science logo LACE56 / LACE56R · High Capacity Centrifuge Series
Technical specification · Beta draft · Non-binding document
Contact: sales@colo.si · +386 64 222 724
LACE56 Series · technical specification High-capacity desktop centrifuge platform with ambient and refrigerated model variants
max. 6000 rpm max. 6321 × g 4 × 750 ml max capacity automatic rotor recognition electronic door lock — Designed for RIA, molecular chemistry, biopharming, cell culture separation, clinical medicine and routine laboratory centrifugation.
📋 Model range · LACE56 with and without refrigeration
Model comparison
Model / SKUConfigurationMain positioning
PRO6932 · LACE56 Normal-temperature / ambient high-capacity centrifuge High-capacity routine centrifugation with broad rotor and adapter selection
PRO6992 · LACE56R Refrigerated high-capacity high-speed centrifuge Temperature-controlled centrifugation for samples requiring cooling protection
Key performance data
ParameterSpecification
Maximum speed6000 rpm
Maximum RCF6321 × g
Maximum capacity4 × 750 ml
Speed accuracy±10 rpm / min
Time setting1 s – 99 min 59 s / 1 min – 99 h 99 min
CertificationCE, ISO
⚙️ Main technical specification
ParameterSpecification
Model No.LACE56 Series
ClassificationMedical centrifuge / laboratory centrifuge
StructureDesktop
MaterialSteel
Maximum speed6000 rpm
Maximum RCF6321 × g
Maximum capacity4 × 750 ml
Power rangeAC 220 ±22 V, 50 Hz, 16 A
ParameterSpecification
Power consumption800 W (confirm per LACE56 / LACE56R)
Weight50 kg (base data supplied; refrigerated model to verify)
Instrument size55 × 47 × 35 cm
External / packing dimension760 × 720 × 540 mm (verify classification)
Transport packageCarton packing
TrademarkCOLO.Science
HS Code8421199090
Document noteBeta technical sheet · data to be checked before final publication
Max. capacity4 × 750 ml
Max. speed6000 rpm
Max. RCF6321 × g
Model versionsLACE56 / LACE56R
Refrigerated-model details are shown only where source data is available. Temperature range, compressor specification, refrigerated-model dimensions and final weight should be added in the final catalogue version.
Page 2 / 8
COLO.Science logo LACE56 Series · Function and Safety Overview
High capacity centrifugation · Rotor recognition · User safety functions
🧪 Function introduction
Control and operation
Automatic rotor identification: helps prevent potential safety hazards caused by incorrect rotor selection.
5-inch touch screen: supports clear parameter setting and easy operation.
Accurate parameter control: centrifugal force can be set to 1 × g, speed can be set to 1 rpm and time can be set to 1 second.
Live parameter display: the large screen displays speed, centrifugal force, time, temperature, acceleration, deceleration and related operating parameters.
Parameter change during operation: parameters can be changed during operation without stopping the centrifuge.
Acceleration, deceleration and workflow
10-level acceleration and deceleration: acceleration and braking can be controlled to help avoid secondary sample mixing during reduction.
Multi-stage procedure: the centrifuge procedure can be set in 10 stages.
Instant centrifugation: quick-spin operation can be used for short workflows.
Timed startup: timed startup function is supported for planned operation.
Speed up / down setting: speed increase and reduction time can be freely set according to the protocol.
Safety and protection
3-level rubber damping: supports good automatic balancing performance and helps reduce vibration.
Imbalance switch protection: imbalance protection is included to support operator safety.
Electronic door lock: the machine adopts an electronic door lock for safe operation.
All-steel inner cavity protection sleeve: the chamber protection design supports operator and instrument safety.
One-time moulding machine structure: designed to improve structural protection and user safety.
Refrigerated operation · LACE56R
Rapid cooling: solenoid valve control is used for rapid cooling function.
Cooling note: source data indicates temperature reduction from 25 °C to 4 °C within 8; final unit should be confirmed before publication, assumed as minutes in this beta draft.
Temperature display: temperature is displayed among the operating parameters on the control screen.
Recommended final data to add: temperature range, cooling time unit, refrigeration system, compressor type, refrigerated-model power consumption and operating ambient conditions.
🧬 Application scope
Clinical and routine laboratories
Blood collection tube workflows
Routine sample separation
Clinical medicine applications
Multi-tube sample preparation
Research and biopharming
Cell culture isolation
Molecular chemistry work
RIA-related workflows
Temperature-sensitive samples with LACE56R
Biosafety configurations
Biosafety centrifuge options
Biosafety airtight rotors
Biosafety airtight adapters
Suitable for hazardous sample centrifugation when configured accordingly
Biosafety statement is configuration-dependent. For dangerous samples such as infectious viruses, infectious bacteria or radioactive samples, final rotor, adapter and sealing configuration must be checked before use.
Page 3 / 8
COLO.Science logo LACE56 Series · Visual Rotor Overview
Available images inserted · Missing adapter visuals reserved as placeholders
🖼️ Main visuals and rotor examples
COLO.Science LACE56 with 4 x 750 ml rotor
LACE56
Centrifuge with 4 × 750 ml rotorHigh-capacity configuration
COLO.Science LACE56 chamber with 4 x 750 ml rotor
Chamber
Chamber with rotor installed4 × 750 ml visual reference
PRO6967 swing out rotor 4 x 750 ml rounded for LACE56 centrifuge
PRO6967
Swing-out rotor · 4 × 750 ml · rounded6000 rpm · 6321 × g
PRO6957 swing out rotor 4 x 500 ml rounded for LACE56 centrifuge
PRO6957
Swing-out rotor · 4 × 500 ml · rounded6000 rpm · 6321 × g
PRO6946 swing out rotor 4 x 250 ml for LACE56 centrifuge
PRO6946
Swing-out rotor · 4 × 250 ml6000 rpm · 6321 × g
PRO6989 swing out microplate rotor 4 x 4 x 96 for LACE56 centrifuge
PRO6989
Microplate holder rack · 4 × 4 × 966000 rpm · 6321 × g
12 x 10 ml rotor for COLO.Science LACE56 centrifuge
PRO6939 / verify
12 × 10 ml rotor · NCP / angle rotor visualCode to verify against PRO6945 line
Adapter image placeholder
ADR
Adapter visuals reserved for later updateEmpty by design in beta version
Biosafety option placeholder
BioSafe
Biosafety rotor / adapter configurationFinal accessory visuals to be added
Visual reference only. Rotor names, final catalogue codes and adapter compatibility should be checked during the next refinement phase.
Page 4 / 8
COLO.Science logo LACE56 Series · Rotor Configuration Guide
Rotor → adapter → sample format · Beta configuration layout
Rotor configuration overview Each rotor is shown with its compatible adapter family · adapter images reserved as placeholders
How to read this section: first select the rotor body according to the main sample format and capacity. Then select the required adapter set. Adapter image positions are intentionally left empty in this beta version and can be filled later after exact adapter photos are matched with the SKU codes.
PRO6945
Rotor 12 × 10 ml · rounded
6000 rpm · 6321 × g
LACE56 rotor 12 x 10 ml rounded PRO6945 visual reference
Direct rotor configuration
12 × 10 ml
Rounded rotor for 12 × 10 ml tube configuration.
Direct rotor use
Image note
Supplied image filename uses PRO6939; table line uses PRO6945.
Code to verify
Adapter set
No separate adapter family listed for this rotor in the supplied data.
Placeholder if needed
PRO6946
Swing-out rotor 4 × 250 ml · square / round cup
6000 rpm · 6321 × g
LACE56 PRO6946 swing-out rotor 4 x 250 ml rounded
Compatible adapter family for PRO6946
PRO6947
ADR Adapter 4 × 4 × 50 ml · conical bottom.
Adapter image placeholder
PRO6948
ADR Adapter 4 × 8 × 15 ml · conical bottom.
Adapter image placeholder
PRO6949
ADR Adapter 4 × 8 × 10 ml · rounded bottom.
Adapter image placeholder
PRO6950
ADR Adapter 4 × 14 × 5 ml · rounded bottom.
Adapter image placeholder
PRO6951
ADR Adapter 4 × 14 × 1.5 / 2 ml · rounded bottom.
Adapter image placeholder
PRO6952
ADR Adapter 4 × 10 × 10 ml · blood collection tube.
Adapter image placeholder
PRO6953
ADR Adapter 4 × 18 × 5 ml · blood collection tube.
Adapter image placeholder
Open slot
Reserved for later image, note or tube compatibility detail.
Empty beta placeholder
Open slot
Reserved for later image, note or tube compatibility detail.
Empty beta placeholder
Page 5 / 8
COLO.Science logo LACE56 Series · 4 × 300 ml and 4 × 500 ml Rotor Families
Rotor families with adapter placeholders
🧩 Rotor families · 4 × 300 ml and 4 × 500 ml
PRO6954
Swing-out rotor 4 × 300 ml · for 250 ml conical-bottom Corning bottle
6000 rpm · 6321 × g
LACE56 PRO6954 swing-out rotor 4 x 300 ml rounded for 250 ml conical-bottom Corning bottle
Compatible adapter family for PRO6954
PRO6955
ADR Adapter 300 to 50 ml for rotor PRO6954 · volume at choice.
Adapter image placeholder
Bottle note
Rotor positioned for 250 ml conical-bottom Corning bottle workflow.
Compatibility note
Open slot
Reserved for later bottle / adapter visual.
Empty beta placeholder
PRO6956
Swing-out biosafety rotor 4 × 500 ml · rounded
6000 rpm · 6321 × g
Biosafety rotor image placeholder
Biosafety configuration area
BioSafe
Biosafety airtight rotor configuration · final accessory set to confirm.
Placeholder
Sealed adapter
Biosafety airtight adapter option · exact code and visual to be added.
Placeholder
Safety note
Use for hazardous samples only after final rotor / sealing configuration is verified.
Configuration note
PRO6957
Swing-out rotor 4 × 500 ml · rounded
6000 rpm · 6321 × g
LACE56 PRO6957 swing-out rotor 4 x 500 ml rounded
Compatible adapter family for PRO6957
PRO6969
ADR Adapter 4 × 4 × 50 ml · conical bottom.
Adapter image placeholder
PRO6960
ADR Adapter 4 × 100 ml · rounded.
Adapter image placeholder
PRO6959
ADR Adapter 4 × 4 × 50 ml · conical bottom.
Adapter image placeholder
PRO6961
ADR Adapter 4 × 9 × 15 ml · conical bottom.
Adapter image placeholder
PRO6962
ADR Adapter 4 × 9 × 10 ml · rounded.
Adapter image placeholder
PRO6950
ADR Adapter 4 × 100 ml · rounded. Code appears elsewhere; verify.
Code to verify
PRO6964
ADR Adapter 4 × 14 × 1.5 / 2 ml.
Adapter image placeholder
PRO6965
ADR Adapter 4 × 12 × 10 ml · blood collection tube · cap-removing.
Adapter image placeholder
PRO6966
ADR Adapter 4 × 14 × 2 / 5 / 7 ml · blood collection tube · cap-removing.
Adapter image placeholder
Page 6 / 8
COLO.Science logo LACE56 Series · 4 × 750 ml Rounded Rotor Family
Large-capacity rotor configuration · rounded bucket family
🧩 Rotor family · PRO6967 · 4 × 750 ml rounded
PRO6967
Swing-out rotor 4 × 750 ml · rounded
6000 rpm · 6321 × g
LACE56 PRO6967 swing-out rotor 4 x 750 ml rounded
Compatible adapter family for PRO6967
PRO6968
ADR Adapter 4 × 500 ml · conical / round bottom.
Adapter image placeholder
PRO6969
ADR Adapter 4 × 250 ml · conical / round bottom.
Code duplicate to verify
PRO6970
ADR Adapter 4 × 3 × 100 ml · conical / round bottom.
Adapter image placeholder
PRO6971
ADR Adapter 4 × 7 × 50 ml · conical.
Adapter image placeholder
PRO6972
ADR Adapter 4 × 14 × 15 ml · conical.
Adapter image placeholder
PRO6973
ADR Adapter 4 × 14 × 10 ml · rounded.
Adapter image placeholder
PRO6974
ADR Adapter 4 × 21 × 5 / 6 ml · rounded.
Adapter image placeholder
PRO6975
ADR Adapter 4 × 26 × 1.5 / 2 ml · conical / rounded.
Adapter image placeholder
PRO6976
ADR Adapter 4 × 19 × 10 ml · blood collection tube · cap removing.
Adapter image placeholder
PRO6977
ADR Adapter 4 × 24 × 5 / 7 ml · blood collection tube · cap removing.
Adapter image placeholder
LACE56 centrifuge with 4 x 750 ml rotor
LACE56 with 4 × 750 ml rotor · high-capacity configuration reference
LACE56 chamber with 4 x 750 ml rotor installed
Chamber with 4 × 750 ml rotor installed · configuration visual reference
Page 7 / 8
COLO.Science logo LACE56 Series · Square, Microplate and Blood Tube Rotor Families
Final configuration page · adapter placeholders and special rotor options
🧩 Rotor family · PRO6978 · 4 × 750 ml square
PRO6978
Swing-out rotor 4 × 750 ml · square
6000 rpm · 6321 × g
Square rotor image placeholder
Compatible adapter family for PRO6978
PRO6979
ADR Adapter 4 × 500 ml · rounded.
Adapter image placeholder
PRO6980
ADR Adapter 4 × 250 ml · rounded.
Adapter image placeholder
PRO6981
ADR Adapter 4 × 3 × 100 ml · rounded.
Adapter image placeholder
PRO6982
ADR Adapter 4 × 7 × 50 ml · conical.
Adapter image placeholder
PRO6983
ADR Adapter 4 × 14 × 15 ml · conical.
Adapter image placeholder
PRO6984
ADR Adapter 4 × 14 × 10 ml · rounded.
Adapter image placeholder
PRO6985
ADR Adapter 4 × 24 × 5 / 6 ml · rounded.
Adapter image placeholder
PRO6986
ADR Adapter 4 × 30 × 1.5 / 2 ml · rounded / conical.
Adapter image placeholder
PRO6987
ADR Adapter 4 × 24 × 10 ml · blood collection tube · cap removing.
Adapter image placeholder
PRO6988
ADR Adapter 4 × 30 × 2 / 5 / 7 ml · blood collection tube · cap removing.
Adapter image placeholder
🧪 Special rotor options
LACE56 PRO6989 microplate holder rack 4 x 4 x 96
PRO6989 · Microplate holder rack

4 × 4 × 96 microplate swing-out rotor configuration.

6000 rpm · 6321 × g
Blood tube rotor image placeholder
PRO6990 · Blood collection tube rotor

Swing-out rotor 96 × 5 / 7 ml for blood collection tubes.

Image to add
Blood tube rotor image placeholder
PRO6991 · Blood collection tube rotor

Swing-out rotor 120 × 5 / 7 ml for blood collection tubes.

Image to add
Manufacturer and configuration support
COLO Lab Experts
Polje ob Sotli 4, SI-3255, Slovenia
Selection guidance: LACE56 Series should be configured according to tube format, bottle format, sample type, required temperature control, biosafety level and preferred rotor family. For final quotation, confirm whether the user needs LACE56 normal-temperature model or LACE56R refrigerated model, and match each rotor with the correct adapter set.
Quick contact
COLO.Science · high-capacity centrifugation support

Request a rotor configuration or quotation for LACE56 / LACE56R

Share the tube format, bottle volume, microplate workflow, sample type, cooling requirement and biosafety expectation. COLO.Science can help define the correct centrifuge model, rotor family and adapter set for the intended laboratory workflow.

Web: colo.si
Beta document control note: each rotor family is visually separated from the next one, and each adapter belongs directly under its rotor. Adapter image spaces are intentionally empty in this beta version so that final photos can be added later without changing the layout logic. Verify refrigerated-model technical data, exact adapter-code mapping, duplicate code PRO6969, rotor code PRO6939 / PRO6945 mismatch and all missing adapter images before final release.
Page 8 / 8