-10%
Hurry Up! Offer ends in:

ALEMADR-DB Dry Bath Incubator RT-25 to 100C


  • RT+5–100°C control
  • ≤±0.3°C @37°C
  • Adjustable heating lid

880,00 980,00

 

ALEMADR-DB — Dry Bath Incubator RT+5 to 100°C

  • RT+5–100°C control
  • 0–100°C setting
  • ≤±0.3°C @37°C
  • Auto-recognized blocks
  • Adjustable heating lid

OVERVIEW

The ALEMADR-DB (and cooling model ALEMADR-DBC) is a sophisticated dry bath incubator designed for precise heating and cooling, controlled by a semiconductor system. Automatic temperature control and a flexible timer make it highly versatile for daily laboratory workflows.

A key advantage is the combined temperature control and block system: each interchangeable block includes its own built-in temperature sensor and heating/cooling unit, enabling accurate control and faster heating. Blocks are auto-recognized for simple setup, and the adjustable heating lid supports controlled lid temperature for condensation-sensitive procedures.

Multi-point and multi-cycle modes (up to 5 points and 99 cycles), auto restart after power failure, over-heating protection and built-in temperature calibration provide robust performance for routine and advanced applications requiring reliable temperature control.

ALEMADR-DB dry bath incubator – semiconductor controlled, interchangeable auto‑recognized blocks, adjustable heating lid, multi‑step programming, and optional cooling model down to –10°C setting. Achieve ≤±0.3°C accuracy at 37°C and fast heat‑up (≤12 min 25→100°C). Perfect for PCR prep, enzymatic assays, and sample incubation.
COLO.Science · Reliable temperature control for your laboratory.


COLO.SCIENCE KNOWLEDGE

Learn more about dry bath incubators in practice

Explore COLO.Science application notes and selection tips for dry block incubation, PCR preparation and temperature‑controlled sample workflows.

Read on COLO.Science →


TYPICAL APPLICATIONS

  • Sample incubation at controlled temperature in microtubes and microplates (via optional blocks)
  • Enzymatic reactions and temperature holds for molecular biology workflows
  • PCR preparation steps where stable block temperature is required
  • Heat treatment and conditioning of small-volume samples
  • Cold storage workflows (cooling model ALEMADR-DBC) at 4°C
  • Routine temperature-controlled protocols in clinical, research and QC laboratories

MODELS & DIMENSIONS

Model Temp setting range Temp control range Dimensions / weight
ALEMADR-DB 0–100°C RT+5–100°C 300 × 200 × 210 mm / 4.0 kg
ALEMADR-DBC –10–100°C RT–25–100°C 300 × 200 × 210 mm / 4.7 kg

Key Advantages of ALEMADR‑DB Series

Smart Block Recognition

Each interchangeable block contains its own sensor and heating/cooling unit. When inserted, the instrument automatically recognizes the block type and applies the correct calibration – no manual adjustments needed.

Multi‑Step Programming

Store and run up to 5 temperature points with individual hold times, and repeat the entire cycle up to 99 times. Ideal for complex protocols like heat shock or enzymatic digestions.

Adjustable Heated Lid

Prevent condensation on tube lids by independently controlling the lid temperature from OFF up to +10°C above block temperature. Essential for long incubations and PCR setups.

Cooling Model Available

The ALEMADR‑DBC variant extends the control range down to –10°C setting (actual block temperature as low as RT–25°C), enabling storage at 4°C and rapid cooling after heat steps.


TECHNICAL SPECIFICATIONS

Product models ALEMADR-DB / ALEMADR-DBC
Temp setting range DB: 0–100°C; DBC: –10–100°C
Temp control range DB: RT+5–100°C; DBC: RT–25–100°C
Time range 1 sec–99 min 59 sec / 1 min–99 h 59 min / ∞
Temp accuracy ≤±0.3°C @37°C
Display accuracy 0.1°C
Temp uniformity ≤±0.3°C @37°C
Heating time ≤12 min (25°C → 100°C)
Cooling time 1 DBC: ≤12 min (100°C → 25°C)
Cooling time 2 DBC: ≤25 min (RT → RT–25°C)
Heating lid temp setting range OFF ~ +10°C
Heating lid temp accuracy ≤±0.5°C*
Heating lid heating time ≤10 min (25°C → 100°C)
Storage at 4°C DBC: Yes
Multi points running Yes (max 5 points)
Multi cycle Yes (max 99 times)
Auto running / auto heating / auto resume Yes / Yes / Yes
Capacity See optional block
Power 150 W
Voltage AC100 or AC220 V / 50–60 Hz
Fuse 250 V, 3 A, Φ5×20
Dimensions (mm) 300 × 200 × 210
Weight (kg) DB: 4.0; DBC: 4.7

STANDARD DELIVERY & ACCESSORIES

  • ALEMADR-DB dry bath incubator main body
  • Power cable / basic installation accessories
  • User manual / quick start guide
  • One optional block (as selected in the offer / order)

Optional blocks (examples):

  • PRO4540 — 35 × 2.0 ml centrifuge tube (RT–25–100°C) *
  • PRO4541 — 35 × 1.5 ml centrifuge tube (RT–25–100°C) *
  • PRO4542 — 54 × 0.5 ml centrifuge tube (RT–25–100°C) *
  • PRO4543 — 96 × 0.2 ml centrifuge tube (RT–25–100°C) *
  • PRO4544 — 96 × 0.2 ml ELISA plate (RT–25–100°C) *
  • PRO4545 — 35 × 2.0 ml centrifuge tube (RT+5–100°C)
  • PRO4546 — 35 × 1.5 ml centrifuge tube (RT+5–100°C)
  • PRO4547 — 54 × 0.5 ml centrifuge tube (RT+5–100°C)
  • PRO4548 — 96 × 0.2 ml centrifuge tube (RT+5–100°C)
  • PRO4549 — 96 × 0.2 ml ELISA plate (RT+5–100°C)

*Blocks PRO4540–PRO4544 are for the cooling model ALEMADR-DBC.


MAIN TECHNICAL PARAMETERS

Model ALEMADR-DB (Main body) / ALEMADR-DBC (Cooling model)
Temp control range DB: RT+5–100°C; DBC: RT–25–100°C
Accuracy / uniformity (@37°C) ≤±0.3°C / ≤±0.3°C
Heating time ≤12 min (25°C → 100°C)
Heating lid control OFF ~ +10°C; ≤±0.5°C*
Multi-point / multi-cycle Yes (max 5 points) / Yes (max 99 cycles)
Power / voltage 150 W / AC100 or AC220 V, 50–60 Hz
Dimensions 300 × 200 × 210 mm
Weight DB: 4.0 kg; DBC: 4.7 kg

*Heating lid temperature accuracy per catalog specification.


ALEMADR-DB — Dry Bath Incubator RT+5 to 100°C

ALEMADR-DB is ideal when you need a versatile dry bath incubator with interchangeable auto‑recognized blocks, adjustable heating lid and multi‑step programming – supported by COLO.Science.

COLO.Science · Reliable temperature control for your laboratory.

SKU: PRO4348, PRO6372 Category: Tag: