COLO.Science · Technical Specification
ALEMADR-DB / DBC
Dry Bath Incubator · Semiconductor precision heating & cooling
The ALEMADR-DB and ALEMADR-DBC are sophisticated dry bath incubators designed for precise heating and cooling, controlled by a semiconductor system. Automatic temperature control, flexible timer, and interchangeable auto‑recognized blocks make them highly versatile for molecular biology, enzymatic reactions, and routine sample incubation. The cooling model (DBC) reaches down to –10°C setting (actual block temp as low as RT–25°C) for cold storage workflows.
RT+5…100°C (DB) RT–25…100°C (DBC) ≤±0.3°C @37°C ≤12 min heating ≤12 min cooling (100→25°C) Auto‑recognized blocks Adjustable heating lid Multi‑point / multi‑cycle Power 150W
Document type: Technical Specification Sheet
Format: Landscape (Word/Outlook-ready)
ALEMADR-DB dry bath incubator
Instrument
ALEMADR-DB / DBC · COLO.Science
Address (HQ)
Polje ob Sotli 4
SI-3255, Slovenia
Contact
COLO.Science logo ALEMADR-DB / DBC · Dry Bath Incubator
Document ID: COL-TEC-ALEMADR-DB-EN
Version: Landscape
Informational technical sheet · Non-binding · Controlled electronic document

ALEMADR‑DB / DBC · Dry Bath Incubator technical specification sheet

DB: RT+5…100°C DBC: RT–25…100°C Time 1s…99h59min/∞ Accuracy ≤±0.3°C @37°C Uniformity ≤±0.3°C Heating lid OFF‑+10°C 150W · AC100/220V — Interchangeable auto‑recognized blocks / Multi‑step programming

📋 general & performance specifications

instrument identity
modelALEMADR-DB (heating) / ALEMADR-DBC (cooling)
grade≤±0.3°C accuracy @37°C
brand / lineCOLO.Science · COLO Lab Experts
instrument typeDry bath incubator, semiconductor controlled
intended usePrecise heating and cooling for molecular biology, enzymatic reactions, sample incubation, PCR preparation, and cold storage (DBC).
temperature control
temp setting rangeDB: 0–100°C; DBC: –10–100°C
temp control rangeDB: RT+5–100°C; DBC: RT–25–100°C
time range1sec ~ 99min59sec / 1min ~ 99h59min / ∞
accuracy (@37°C)≤±0.3°C
display accuracy0.1°C
uniformity (@37°C)≤±0.3°C
heating / cooling performance
heating time≤12 min (25°C → 100°C)
cooling time 1 (DBC)≤12 min (100°C → 25°C)
cooling time 2 (DBC)≤25 min (RT → RT–25°C)
heating lid
temp setting rangeOFF ~ +10°C (relative to block temp)
accuracy≤±0.5°C
heating time≤10 min (25°C → 100°C)
programming & safety
multi‑point runningYes (max 5 points)
multi‑cycleYes (max 99 times)
auto running / auto heatingYes / Yes
auto resume after power failYes
over‑heating protectionYes
built‑in temperature calibrationYes
storage at 4°C (DBC)Yes
physical & electrical
power150 W
voltageAC100 or AC220 V / 50–60 Hz
fuse250 V, 3 A, Φ5×20
dimensions (mm)300 × 200 × 210
weightDB: 4.0 kg; DBC: 4.7 kg
block capacitysee optional blocks

⚙️ key instrument features

LCD screenInstantly displays operation information.
Combined temp control & blockEach block has built‑in sensor and heating/cooling unit for accurate control and faster heating.
Interchangeable, auto‑recognized blocksEnhances flexibility and ease of use.
Adjustable heating lidAllows control of lid temperature (OFF to +10°C).
Multi‑point & multi‑cycle modesUp to 5 points and 99 cycles.
Auto restart after power failureEnsures continuity of experiments.
Over‑heating protectionEnhances safety.
Built‑in temperature calibrationMaintains long‑term accuracy.

🧪 typical laboratory applications

Sample incubation in microtubes / microplates
Enzymatic reactions and temperature holds
PCR preparation steps
Heat treatment / conditioning of small volumes
Cold storage at 4°C (DBC model)
Routine temperature‑controlled protocols in clinical, research, QC labs

📦 standard delivery (typical)

  • ALEMADR-DB main body
  • Power cable & basic accessories
  • User manual / quick start guide
  • One optional block (as selected in offer/order)

🧩 optional blocks

CodeCapacityTemp rangeModel
PRO454035×2.0ml centrifuge tubeRT–25…100°CDBC
PRO454135×1.5ml centrifuge tubeRT–25…100°CDBC
PRO454254×0.5ml centrifuge tubeRT–25…100°CDBC
PRO454396×0.2ml centrifuge tubeRT–25…100°CDBC
PRO454496×0.2ml Elisa plateRT–25…100°CDBC
PRO454535×2.0ml centrifuge tubeRT+5…100°CDB
PRO454635×1.5ml centrifuge tubeRT+5…100°CDB
PRO454754×0.5ml centrifuge tubeRT+5…100°CDB
PRO454896×0.2ml centrifuge tubeRT+5…100°CDB
PRO454996×0.2ml Elisa plateRT+5…100°CDB

*PRO4540–PRO4544 only for cooling model ALEMADR‑DBC.

🔬 practical operation notes

topicrecommendationnote
block selection Use matching block for your tube/plate type and required temperature range (DB or DBC). Auto‑recognition simplifies setup.
heating lid Enable lid heating (OFF‑+10°C) to prevent condensation, especially for long runs. Prevents evaporation and well‑to‑well variation.
multi‑step programming Program up to 5 points with individual hold times; repeat up to 99 cycles. Ideal for heat‑shock, enzymatic digestions, etc.
temperature calibration Use built‑in calibration to maintain accuracy over time; check with reference thermometer. Follow user manual procedure.

📄 reference PDF: ALEMADR-DB.pdf
🧪 application guidance: workflow‑based block selection
🛠️ maintenance: clean blocks, ensure good contact
🧾 procurement: binding spec = quotation package

📌 Contact & Support

Headquarters address
Polje ob Sotli 4
SI-3255, Slovenia
Application guidance: tell us your tube/plate type, temperature range, and throughput.
We will propose the matching block configuration and accessories for your workflow.
Quick contact
Web: colo.si
PDF Tech Spec: ALEMADR-DB.pdf
Email: sales@colo.si
Knowledge hub: COLO.Science
Manufacturer & configuration notice (important):
Specifications in this document are provided for general reference and may represent a typical configuration. COLO reserves the right to change technical specifications without notice.

For procurement and tender purposes, the only valid and binding specification is the official COLO quotation and the accompanying technical specification that is engineering-approved.