COLO.SCIENCE — HIGH- AND LOW-SPEED FLEXIBILITY ON ONE BENCHTOP PLATFORM
RITACUBA20N high-speed centrifuge for microtubes, blood tubes and vessels up to 250 ml
RITACUBA20N is designed for laboratories that need more than a dedicated microcentrifuge. Interchangeable fixed-angle and swing-out rotors extend the usable sample range from microtubes to larger laboratory vessels, including 250 ml swing-out cups and common blood collection tube formats.
The platform therefore covers two distinct operating profiles: high-speed processing for small tubes and lower-speed, higher-capacity separation for larger sample batches. Automatic rotor recognition helps align the operating range with the installed compatible rotor.
Up to 999 stored programs, ±10 rpm speed accuracy and ten acceleration/deceleration levels support laboratories that repeat many different centrifugation methods on the same instrument.
Key characteristics
- 20,000 rpm maximum instrument speed.
- 29,060 × g maximum instrument RCF.
- 4 × 250 ml maximum declared capacity.
- Broad 2–250 ml sample-format capability through compatible rotors.
- ±10 rpm speed accuracy.
- Up to 999 custom programs.
- 5-inch HD touchscreen and optional USB export.
- Ambient / non-refrigerated operation.
Suitable for
- High-speed microtube workflows.
- Routine 5, 10, 15 and 50 ml tube separation.
- Blood collection tubes with suitable swing-out adapters.
- Higher-volume processing up to 4 × 250 ml.
- Clinical, molecular biology and biochemical sample preparation.
- Research, bioengineering and agricultural laboratory workflows.
SELECTION NOTE — RITACUBA20N CONFIGURATION
RITACUBA20N high-speed centrifuge with broad rotor and capacity flexibility
The RITACUBA20N high-speed centrifuge should be configured from the sample and method rather than from the instrument maximum speed alone. First define tube or vessel geometry, working volume, samples per run and target RCF; then select the compatible rotor and required adapter.
This is especially important because the same platform combines high-speed fixed-angle rotors with lower-speed, higher-capacity rotors. The published 20,000 rpm and 29,060 × g figures are maximum instrument values; every installed rotor, adapter and tube must remain within its own stated limit.
The centrifuge unit, rotor and adapters are selected and quoted separately unless a specific package is explicitly defined. Final compatibility and delivery scope are confirmed in the binding quotation.
From high-speed microtubes to 4 × 250 ml swing-out separation

High- and low-speed capability is the key difference
High-speed angle rotors support microtube and smaller-volume separation, while the PRO6946 swing-out rotor expands the platform to 4 × 250 ml and supports adapters for 50, 15, 10, 5 and 1.5 ml tubes plus blood collection tubes.
Selected NCP composite rotors combine low mass, high strength, low thermal conductivity and corrosion resistance. The nano-ceramic-coated rotor chamber adds a smooth corrosion-resistant surface.
The single-stamped T45 steel body, three-stage rubber vibration absorption and automatic balancing support stable operation at a specified noise level of ≤60 dB(A).
TECHNICAL SPECIFICATIONS — RITACUBA20N HIGH-SPEED CENTRIFUGE
| Model | RITACUBA20N |
| Order number / SKU | PRO7072 |
| Type | Benchtop high- and low-speed laboratory centrifuge, non-refrigerated |
| Maximum speed | 20,000 rpm |
| Maximum RCF | 29,060 × g |
| Maximum capacity | 4 × 250 ml |
| Speed accuracy | ±10 rpm |
| Timer | 1 s–99 min 59 s / 1 min–99 h 59 min |
| Stored programs | Up to 999 custom programs |
| Acceleration / deceleration | 10 adjustable levels |
| Display | 5-inch HD touchscreen |
| Data export | USB optional |
| Total power | 700 W |
| Power supply | AC 220 V ±10%, 50 Hz, 10 A |
| Dimensions (W × D × H) | 55 × 47 × 31 cm |
| Net weight | 38 kg |
| Noise level | ≤60 dB(A) |
| Temperature control | Ambient / non-refrigerated |
20,000 rpm and 29,060 × g are maximum instrument specifications. Actual speed, RCF and capacity depend on the selected rotor and must remain within rotor, adapter and tube limits.
Compatible rotors for the RITACUBA20N high-speed centrifuge
NCPComposite Rotor Technology
Lightweight · corrosion-resistant · low thermal conductivity
PRO6941 · 12 × 5 ml ADR adapter: round-bottom tube adapter for use with rotor PRO6940, subject to the PRO6940 limit of 11,000 rpm / 15,620 × g.
Method storage, rotor recognition and operational control
Up to 999 custom programs
Store and recall frequently repeated methods to improve consistency across users and shifts.
Automatic rotor detection
The system detects the installed compatible rotor and provides timely alert support.
Programmable dynamics
Ten acceleration/deceleration levels with soft start/stop help protect gradients and sensitive pellets.
Multiple operating modes
Timed, jog, differential and gradient modes support routine and specialised protocols.
Imbalance and vibration support
Imbalance protection, automatic balancing and three-stage rubber shock absorption support stable operation.
Emergency lid release
Provides controlled access after a power interruption, only after the rotor has fully stopped.
Applications of the RITACUBA20N high-speed centrifuge
Clinical laboratories
Suitable configurations can support validated separation of blood fractions, urine sediments and other clinical specimens.
Molecular biology
High-speed microtube rotors support cell pelleting, nucleic-acid preparation and general microtube workflows.
Biochemistry
Multiple tube and vessel capacities support clarification, phase separation and sample preparation.
Bioengineering and agriculture
The wide rotor range supports cell suspensions, cultures, research specimens and larger-volume sample preparation.
RITACUBA20N PLATFORM SELECTION
Why choose RITACUBA20N for mixed high- and low-speed laboratory work?
RITACUBA20N is useful when one laboratory needs both microtube centrifugation and larger-volume batch separation without active refrigeration. Fixed-angle and swing-out rotors allow the platform to move between high-speed small-volume methods and lower-speed high-capacity processing.
For temperature-sensitive protocols, select a refrigerated centrifuge instead. RITACUBA20N is explicitly an ambient, non-refrigerated model.
LABORATORY CENTRIFUGES CATALOGUE
Compare speed, capacity and rotor configurations
Compare speed, RCF, capacity, tube formats, rotor type, refrigeration and application fit before selecting the final configuration.
COLO.SCIENCE — KNOWLEDGE AND SUPPORT
Configure the centrifuge from the sample and target RCF
COLO.Science supports selection by matching tube geometry, sample volume, target RCF, throughput, rotor type, balancing and documentation needs.
How to select the correct rotor for the RITACUBA20N high-speed centrifuge
Start with the consumable and method: tube, vessel or blood collection tube type, working volume, geometry, chemical compatibility and the consumable manufacturer’s maximum permitted RCF or speed. Then define sample count and required centrifugal force.
Next decide whether the workflow is primarily high-speed/small-volume or lower-speed/higher-capacity. This determines whether a microtube angle rotor, larger angle rotor or swing-out rotor is the best starting point.
Never apply the instrument’s 20,000 rpm maximum to a rotor rated for a lower speed. The correct operating limit is always the lowest applicable limit among centrifuge, rotor, adapter and tube.
RITACUBA20N high-speed centrifuge FAQ
What is the maximum performance of RITACUBA20N?
The instrument is specified for up to 20,000 rpm and 29,060 × g, with maximum declared capacity of 4 × 250 ml. Actual values depend on the installed rotor.
Is RITACUBA20N refrigerated?
No. RITACUBA20N is an ambient, non-refrigerated centrifuge.
Can RITACUBA20N handle 250 ml vessels?
Yes. PRO6946 provides 4 × 250 ml swing-out capacity at up to 4,000 rpm and 3,040 × g.
Are rotor and adapters included?
The centrifuge is supplied as a centrifuge unit. Rotor and required adapters are selected separately unless a quotation explicitly defines a complete package.
Does every compatible rotor operate at 20,000 rpm?
No. 20,000 rpm is the maximum instrument specification. Each rotor has its own maximum speed and RCF, which must never be exceeded.
Configuration notice
The official quotation defines the final RITACUBA20N delivery scope, including centrifuge unit, selected rotor, adapters, electrical configuration, optional USB export and documentation requirements. Exact performance, capacity, compatibility and included components depend on the selected configuration. Specifications may change without notice.
Need help configuring the RITACUBA20N high-speed centrifuge?
Send us the tube or vessel type, sample volume, required capacity, sample count per run and target RCF. COLO.Science can verify the centrifuge, rotor and adapter combination before quotation.
COLO LABEXPERTS — PRODUCT SUPPORT
COLO LabExperts · Slovenia
Polje ob Sotli 4, SI-3255 Slovenia
Email: sales@colo.si
WhatsApp / Viber: +386 70 713 437
RITACUBA20N high-speed centrifuge — up to 20,000 rpm, 29,060 × g and 4 × 250 ml; non-refrigerated operation, 5-inch HD touchscreen, automatic rotor recognition, up to 999 custom programs and a broad rotor range for high-speed microtube and higher-capacity workflows.