Two Shops
One Shipment
,

LACE16AR refrigerated high-speed centrifuge with NCP composite rotors 16,500 rpm, 24,148 × g


LACE16AR refrigerated high-speed centrifuge for molecular biology and temperature-sensitive samples — 16,500 rpm, 24,148 × g, -20 °C to +40 °C, capacity up to 18 × 5 ml, 4 NCP rotors, nano-ceramic chamber and 5-inch touch screen.

COLO.Science — CENTRIFUGES / REFRIGERATED HIGH-SPEED CENTRIFUGES — LACE16AR

LACE16AR refrigerated high-speed centrifuge with NCP composite rotors

LACE16AR refrigerated high-speed centrifuge is a compact benchtop platform for DNA/RNA extraction, protein purification, PCR, cell separation and other temperature-sensitive laboratory workflows. It combines 16,500 rpm, 24,148 × g, a declared maximum capacity of 18 × 5 ml and precise temperature control from -20 °C to +40 °C with four confirmed NCP fixed-angle rotors, automatic rotor recognition and a 5-inch touch screen.

LACE16AR refrigerated high-speed centrifuge with 5-inch touch screen

COLO.SCIENCE — PRECISION-COOLED HIGH-SPEED CENTRIFUGATION

Compact refrigerated centrifuge for heat-sensitive samples

LACE16AR is designed for laboratories that need high centrifugal force together with controlled low-temperature operation. Smart refrigeration control, an eco-friendly refrigerant and temperature accuracy of ±1 °C support stable processing of samples that may be affected by heat generated during high-speed centrifugation.

The instrument stores 99 user-defined programs, provides 10 acceleration and 10 deceleration levels, displays live operating parameters and allows settings to be adjusted during a run without stopping the centrifuge.

Key characteristics

  • Maximum speed 16,500 rpm and maximum RCF 24,148 × g.
  • Temperature setting from -20 °C to +40 °C with ±1 °C accuracy.
  • Declared maximum capacity 18 × 5 ml.
  • Four confirmed NCP fixed-angle rotors.
  • Nano-ceramic coated rotor chamber.
  • 5-inch high-definition touch screen.
  • 99 stored programs and quick-start centrifugation.
  • 10 acceleration and 10 deceleration levels.

Suitable for

  • DNA and RNA extraction workflows.
  • Protein purification and molecular biology.
  • PCR and temperature-sensitive sample preparation.
  • PRP, cell separation and small-sample processing.
  • Biological, medical and pharmaceutical laboratories.
  • Agricultural, chemical and disease-control laboratories.

TWO MATERIAL TECHNOLOGIES — ROTOR AND CHAMBER

NCP composite rotors and a nano-ceramic coated rotor chamber


NCP
Composite Rotor TechnologyLightweight · corrosion-resistant · learn more

NCP composite rotor platform

The four confirmed fixed-angle rotors use NCP composite construction. Lower rotor mass, high strength, slower heat conduction and resistance to conventional aluminium corrosion support practical handling and temperature-sensitive centrifugation workflows.

NANO
Nano-Ceramic ChamberCorrosion-resistant · easier cleaning · durable

Nano-ceramic coated rotor chamber

The rotor chamber is nano-ceramic coated for resistance to corrosion and rust. The smooth protected surface supports easier cleaning, lower maintenance demands and longer chamber service life in refrigerated laboratory operation.

Technical distinction: the rotors are NCP composite components; the centrifuge chamber has the nano-ceramic coating. These are separate technologies with complementary functions.

SELECTION NOTE — REFRIGERATED CENTRIFUGE CONFIGURATION

LACE16AR refrigerated high-speed centrifuge for controlled sample processing

LACE16AR is suited to laboratories that need to combine high RCF performance with a defined temperature profile. The -20 °C to +40 °C setting range allows methods to be adapted to sample stability requirements, while smart cooling control helps maintain low-temperature operation during high-speed runs.

Rotor selection should begin with tube geometry, nominal volume, cap design and the consumable manufacturer’s maximum speed or RCF rating. The confirmed rotor range covers 0.5 ml, 1.5 / 2 ml and 5 ml round-bottom formats. Final refrigerated operating limits should be confirmed for the selected rotor and tube configuration.

For procurement and method transfer, COLO can help define the centrifuge, rotor SKU, tube format, target RCF, required temperature profile, balancing requirements and optional USB data export.

Compact refrigerated benchtop design with touch control

LACE16AR refrigerated centrifuge with open lid and nano-ceramic rotor chamber

52 × 32 × 23 cm refrigerated platform

The compact desktop structure integrates refrigeration, a 5-inch touch interface and a corrosion-resistant rotor chamber in a footprint suitable for laboratories where bench space is limited.

The electronic lid lock allows opening only at zero speed. Emergency manual release, imbalance protection, over-temperature protection and over-speed protection support safe routine operation.

TECHNICAL SPECIFICATIONS — LACE16AR REFRIGERATED HIGH-SPEED CENTRIFUGE

Product LACE16AR refrigerated high-speed centrifuge
Product number / SKU PRO7067
Structure Desktop / benchtop refrigerated centrifuge
Maximum speed 16,500 rpm
Maximum RCF 24,148 × g
Declared maximum capacity 18 × 5 ml
Confirmed rotor range Four fixed-angle NCP composite rotor configurations
Confirmed tube formats 0.5 ml, 1.5 / 2 ml and 5 ml round-bottom tubes, rotor-dependent
Temperature setting -20 °C to +40 °C
Temperature accuracy ±1 °C
Cooling control Smart temperature control with operating-mode switching
Refrigerant Eco-friendly refrigerant
Timer range 1 s–99 min 59 s / 1 min–99 h 59 min
Display / control 5-inch high-definition touch screen
Speed accuracy ±10 rpm
RCF accuracy 1 × g
Stored programs 99 user-defined programs
Acceleration / deceleration 10 selectable levels / 10 selectable levels
Motor AC frequency-conversion motor
Run modes Differential timing, gradient, point movement and timed centrifugation
Parameter change during run Yes, without stopping
Automatic slowdown Automatic slowdown and stop at max. 500 rpm
Rotor recognition Automatic rotor identification with alarm support
Rotor material NCP composite material
Rotor chamber Nano-ceramic coated, corrosion- and rust-resistant
Body material T45 high-strength steel, one-piece stamped construction
Damping / balance 3-level rubber shock absorption with automatic balancing
Door safety Electronic lock; lid opens only at zero speed
Emergency lid release Manual opening device for power failure
Safety shutdown Imbalance, over-temperature and over-speed protection
Noise ≤ 52 dB(A)
Power supply AC 220 ± 22 V, 50 Hz, 10 A
Power consumption 800 W
Net weight 35 kg
Dimensions (W × D × H) 52 × 32 × 23 cm
Data export Optional USB export
HS code 8421199090

Final performance depends on the selected rotor, tube format, tube manufacturer limits, correct balancing, selected temperature profile, program, sample load and laboratory SOP. Confirm the final refrigerated operating configuration and documentation package in the official quotation.

NCP TECHNOLOGY
PRO3885 12 x 1.5 2 ml NCP rotor for LACE16AR refrigerated centrifuge

COLO rotor SKU: PRO3885

12 × 1.5 / 2 ml

16,500 rpm · 21,610 × g
NCP fixed-angle rotor

NCP TECHNOLOGY
PRO5462 48 x 0.5 ml NCP rotor for LACE16AR refrigerated centrifuge

COLO rotor SKU: PRO5462

48 × 0.5 ml

15,000 rpm · 21,256 × g
NCP fixed-angle rotor

NCP TECHNOLOGY
PRO6935 24 x 1.5 2 ml NCP rotor for LACE16AR refrigerated centrifuge

COLO rotor SKU: PRO6935

24 × 1.5 / 2 ml

15,000 rpm · 22,387 × g
NCP fixed-angle rotor

NCP TECHNOLOGY
PRO6938 18 x 5 ml NCP rotor for LACE16AR refrigerated centrifuge

COLO rotor SKU: PRO6938

18 × 5 ml, round bottom

15,000 rpm · 24,148 × g
NCP fixed-angle rotor

Rotor configuration control: the four listed NCP rotors are the confirmed rotor set for the LACE16AR / PRO7067 configuration presented here. Confirm the selected rotor SKU, tube limits and permitted refrigerated operating profile in the binding quotation.

Cooling control, repeatable methods and safety support

Precision cooling

Smart temperature control provides a -20 °C to +40 °C setting range with ±1 °C accuracy for heat-sensitive laboratory workflows.

Automatic rotor recognition

Rotor auto-identification with alarm support reduces the risk of selecting an incorrect rotor profile.

Stored operating methods

Up to 99 user-defined programs store frequently used speed, RCF, time, temperature and acceleration settings.

Controlled acceleration and braking

Ten acceleration and ten deceleration levels help adapt the operating profile to sensitive samples and routine methods.

Applications of the LACE16AR refrigerated centrifuge

DNA/RNA extraction and PCR

High RCF performance and controlled cooling support molecular workflows where sample temperature and reproducibility are important.

Protein purification

Stored programs and adjustable temperature profiles help standardise repeated protein-processing procedures.

Cell and PRP processing

Selectable acceleration and braking levels support controlled separation profiles for cell, PRP and other small-sample workflows.

Research and routine laboratories

The compact refrigerated platform is suitable for biological, medical, pharmaceutical, agricultural and chemical laboratories.

LABORATORY CENTRIFUGES CATALOGUE

Compare refrigerated centrifuges and rotor configurations

Use the centrifuge catalogue to compare speed, RCF, temperature range, capacity, tube formats, rotor systems and application fit.

Open catalogue →

COLO.SCIENCE KNOWLEDGE AND SUPPORT

Rotor and temperature-profile selection support

COLO.Science supports centrifuge selection by matching tube geometry, sample volume, target RCF, temperature requirements, throughput, balancing and the complete rotor configuration.

COLO.Science →

How to configure the LACE16AR refrigerated high-speed centrifuge

Start with the sample method and tube. Confirm nominal volume, tube diameter, bottom geometry, cap design, actual fill volume and the consumable manufacturer’s speed or RCF limit. Then compare rotor capacity, maximum RCF and required throughput.

Define the required temperature profile, expected run duration and sample sensitivity. All rotor loads must be symmetrical and operated according to the laboratory SOP. Final speed, RCF and temperature settings must remain within the approved limits of the selected rotor and tubes.

LACE16AR refrigerated centrifuge FAQ

What temperature range does LACE16AR provide?

The temperature can be set from -20 °C to +40 °C with a stated accuracy of ±1 °C.

Which rotors are confirmed for product number PRO7067?

Four NCP fixed-angle rotors are listed: PRO3885, PRO5462, PRO6935 and PRO6938. They cover 0.5 ml, 1.5 / 2 ml and 5 ml tube formats.

What is nano-ceramic coated?

The rotor chamber is nano-ceramic coated for corrosion and rust resistance. The compatible rotors use NCP composite construction.

Configuration notice

The official quotation defines the final LACE16AR delivery scope, including the centrifuge unit, selected rotor, permitted refrigerated operating profile, optional USB export, electrical configuration and documentation requirements. Website content is intended for general product presentation and may not represent the exact delivered configuration. Specifications may change without notice.

Need help choosing a LACE16AR refrigerated rotor configuration?

Contact COLO.Science to confirm the centrifuge unit, rotor SKU, tube format, sample volume, target RCF, temperature profile, balancing requirements and documentation package.

SKU: PRO7067 Categories: ,

Request a Quote