COLO.SCIENCE — TOUCH-CONTROLLED HIGH-SPEED CENTRIFUGATION
Compact laboratory centrifuge with verified NCP rotor compatibility
LACE16AS provides a compact platform for routine separation workflows in schools, hospitals, research laboratories and medical or biological facilities. Its AC frequency-conversion motor, real-time parameter display and automatic rotor recognition support repeatable operation across four confirmed rotor configurations for 0.5 ml, 1.5 / 2 ml and 5 ml tube formats.
The benchtop high-speed centrifuge stores up to 99 user-defined programs and allows speed, RCF, time, acceleration and deceleration settings to be reviewed during operation. Parameters can also be adjusted without stopping the run.
Key characteristics
- Maximum speed 16,500 rpm and maximum RCF 24,148 × g.
- Declared maximum capacity 18 × 5 ml.
- Four confirmed NCP fixed-angle rotors.
- 5-inch high-definition touch screen.
- Automatic rotor recognition with alarm support.
- 99 user-defined programs and instant centrifugation.
- 10 acceleration and 10 deceleration levels.
- Optional USB data export.
Suitable for
- Radioimmunology and biochemical laboratories.
- Pharmaceutical and medical laboratory workflows.
- Biological research and routine sample preparation.
- Hospital and educational laboratory use.
- 0.5 ml microtube processing.
- 1.5 / 2 ml and 5 ml round-bottom tube configurations.
SELECTION NOTE — LACE16AS ROTOR CONFIGURATION
LACE16AS benchtop high-speed centrifuge for verified tube formats
The LACE16AS benchtop high-speed centrifuge is a practical choice when a laboratory needs high RCF performance, touch control and a clearly defined rotor selection. The confirmed rotor range includes a 12-place rotor for 1.5 / 2 ml tubes, a 24-place rotor for 1.5 / 2 ml tubes, a 48-place rotor for 0.5 ml tubes and an 18-place rotor for 5 ml round-bottom tubes.
Rotor selection should begin with the actual tube geometry, nominal volume, cap design and the tube manufacturer’s maximum speed or RCF rating. The required throughput and target centrifugal force can then be matched to the appropriate NCP rotor. The published rotor compatibility is deliberately limited to the four records explicitly confirmed for product number PRO2803.
For procurement and method transfer, COLO can help confirm the centrifuge, rotor SKU, tube format, operating profile, balancing requirements and optional data export. Final compatibility and the exact delivery scope should be stated in the binding quotation.
LACE16AS high-speed performance with a composite rotor platform

NCP composite rotors for routine laboratory use
NCP composite construction combines low rotor mass with high strength, slower heat conduction and resistance to corrosion. These properties support convenient rotor handling and help reduce the thermal and chemical limitations associated with conventional metal rotor construction.
The representative PRO6938 rotor provides 18 × 5 ml round-bottom capacity at up to 15,000 rpm and 24,148 × g. Final operation must always respect the rated limits of the selected tubes and the laboratory SOP.
TECHNICAL SPECIFICATIONS — LACE16AS BENCHTOP HIGH-SPEED CENTRIFUGE
| Product | LACE16AS benchtop high-speed centrifuge |
| Product number / SKU | PRO2803 |
| Structure | Desktop / benchtop |
| Maximum speed | 16,500 rpm |
| Maximum RCF | 24,148 × g |
| Declared maximum capacity | 18 × 5 ml |
| Confirmed rotor range | Four fixed-angle NCP composite rotor configurations |
| Tube formats | 0.5 ml, 1.5 / 2 ml and 5 ml round-bottom tubes, rotor-dependent |
| Display / control | 5-inch high-definition touch screen |
| Stored programs | 99 user-defined programs |
| Acceleration / deceleration | 10 selectable levels / 10 selectable levels |
| Motor | AC frequency-conversion motor |
| Run modes | Differential timing, gradient, point movement and timed centrifugation |
| Parameter memory | All run parameters can be stored and reused |
| Instant centrifugation | Supported |
| Parameter change during run | Yes, without stopping |
| Speed accuracy | 1 rpm |
| RCF accuracy | 1 × g |
| Time accuracy | 1 second |
| Rotor recognition | Automatic rotor identification with alarm support |
| Rotor chamber | Stainless steel |
| Body material | T45 high-strength steel, one-piece stamped construction |
| Rotor material | NCP composite material |
| Damping / balance | 3-level rubber shock absorption with automatic balancing |
| Door safety | Electronic lock; lid opens only at zero speed |
| Emergency lid release | Manual opening device for unexpected power failure |
| Safety shutdown | Imbalance, over-temperature and over-speed protection |
| Noise | ≤ 60 dB(A) |
| Power supply | AC 220 ± 22 V, 50 Hz, 10 A |
| Power consumption | 500 W |
| Data export | Optional USB export |
| Typical applications | Radioimmunology, biochemistry, pharmaceutical, medical and biological laboratories |
| HS code | 8421199090 |
Final centrifugation performance depends on the selected rotor, tube format, tube manufacturer limits, correct balancing, selected program, sample load and laboratory SOP. The final configuration and documentation package should be confirmed in the official quotation.
Four confirmed NCP rotors for LACE16AS
NCP
Composite Rotor TechnologyLightweight · corrosion-resistant · learn more

Rotor SKU: PRO3885
12 × 1.5 / 2 ml
16,500 rpm · 21,610 × g
NCP angle rotor · Ref. FNCP-45-122

Rotor SKU: PRO5462
48 × 0.5 ml
Maximum speed to confirm · 21,256 × g
NCP angle rotor · Ref. FNCP-45-32PCR

Rotor SKU: PRO6935
24 × 1.5 / 2 ml
15,000 rpm · 22,387 × g
NCP angle rotor · Ref. FNCP-45-242

Rotor SKU: PRO6938
18 × 5 ml, round bottom
15,000 rpm · 24,148 × g
NCP angle rotor · Ref. FNCP-45-185
Rotor compatibility control: only the four rotor records explicitly linked to LACE16AS / PRO2803 are presented here. Rotors and adapters from the broader 3-16N or RITACUBA platform are not automatically considered compatible. The maximum speed of PRO5462 must be confirmed before quotation.
Touch control, repeatable methods and safety support
5-inch touch control
The display shows speed or RCF, time, acceleration, deceleration and stored program data for quick review during operation.
Automatic rotor recognition
Rotor auto-identification with alarm support helps reduce the risk of selecting an incorrect rotor profile.
Stored operating methods
Up to 99 user-defined programs can store frequently used centrifugation parameters for consistent routine processing.
Controlled acceleration and braking
Ten acceleration and ten deceleration levels help adapt the operating profile to sensitive samples and routine laboratory methods.
Applications of the LACE16AS laboratory centrifuge
Biochemistry and radioimmunology
High-speed performance and selectable operating profiles support routine separation steps in biochemical and radioimmunology workflows.
Pharmaceutical laboratories
Stored programs and documented rotor configurations help standardise recurring sample-preparation procedures.
Medical and biological work
The rotor range covers common microtube and small laboratory tube formats used in routine medical and biological processing.
Educational and hospital laboratories
Touch operation, method storage and automatic rotor identification simplify repeated use by trained laboratory personnel.
LABORATORY CENTRIFUGES CATALOGUE
Compare centrifuge platforms and rotor configurations
Use the centrifuge catalogue to compare maximum speed, RCF, capacity, tube formats, control systems and application fit.
COLO.SCIENCE KNOWLEDGE AND SUPPORT
Rotor selection support for high-speed centrifugation
COLO.Science supports centrifuge selection by matching tube geometry, sample volume, target RCF, throughput, balancing requirements and the required operating profile.
How to select the correct LACE16AS rotor
Start with the tube rather than the centrifuge’s maximum speed. Confirm nominal volume, tube diameter, bottom geometry, cap design, actual fill volume and the tube manufacturer’s speed or RCF limit. Then compare the confirmed rotor capacity, maximum RCF and required throughput.
All rotor loads must be symmetrical and operated according to the laboratory SOP. For the PRO5462 configuration, the maximum permitted rotor speed remains an open item and should be confirmed in the final quotation before the method is approved.
LACE16AS centrifuge FAQ
What is the maximum performance of LACE16AS?
The centrifuge reaches up to 16,500 rpm and 24,148 × g. The actual maximum values depend on the selected rotor.
Which rotors are confirmed for product number PRO2803?
Four NCP fixed-angle rotors are confirmed: PRO3885, PRO5462, PRO6935 and PRO6938. They cover 0.5 ml, 1.5 / 2 ml and 5 ml tube formats.
Can operating parameters be changed during a run?
Yes. The technical specification states that parameters can be changed during operation without stopping the centrifuge.
Configuration notice
The official quotation defines the final LACE16AS delivery scope, including the centrifuge unit, selected rotor, optional USB export, electrical configuration and documentation requirements. Website content is intended for general product presentation and may not represent the exact delivered configuration. Specifications may change without notice.