COLO.Science · Incubation · Forced-air incubators
MBINE laboratory incubators, 30–230 L, with forced convection and two-section PID control
The MBINE laboratory incubator series covers six chamber sizes from 30 L to 230 L for above-ambient incubation from RT+5 to 120 °C in microbiology, cell-culture support, stability testing, quality control and education. Every model combines a vertical double-duct air supply with horizontal circulation, two-section intelligent PID regulation, a mirror-polished stainless-steel chamber, an LCD controller with touch buttons, a double-layer door with a tempered glass observation window and an over-temperature protection system with an independent digital temperature limiter.

MBINE30 · MBINE45 · MBINE65 · MBINE85 · MBINE125 · MBINE230 — each model has its own SKU
Forced-convection incubation with two-section PID control
Each MBINE laboratory incubator uses a vertical double-duct air supply with horizontal forced-air circulation and a fan with three adjustable speeds and LED running indicator (fixed speed on MBINE230), so temperature distribution can be matched to the sample type, from open plates to closed vessels. Two-section PID control with a Pt100 sensor, sensor-deviation correction and overshoot self-tuning keeps the setpoint stable within ±1 °C.
The LCD controller shows measured and set temperature on two rows and provides touch-button setting, a 0–9999 min timer with timing-wait function, auto stop, parameter locking and memory after a power cut, while the double-layer door with tempered glass allows visual checks without opening the chamber.
Key characteristics
- RT+5 to 120 °C, resolution 0.1 °C, uniformity ±1 °C
- Two-section intelligent PID with Pt100 sensor
- Vertical double-duct supply, horizontal circulation, 3 fan speeds
- Mirror-polished stainless-steel chamber
- LCD controller, timer 0–9999 min
- Heating cut-off and independent digital temperature limiter
- Six chamber sizes: 30, 45, 65, 85, 125 and 230 L
Suitable for
- Microbiological cultivation and testing
- Cell-culture support work
- Food, beverage and pharmaceutical QC
- Stability testing in pharmacy and industry
- Medical and research laboratories
- Educational laboratories
MBINE laboratory incubator series for reliable forced-air incubation
The MBINE forced-air laboratory incubator series supports controlled above-ambient incubation up to 120 °C with six practical volumes, a mirror stainless-steel chamber, Pt100 sensor, two-section PID control and layered temperature protection. It is intended for users who need stable conditions, simple LCD operation and a chamber size that follows the actual sample load.
MBINE forced-air laboratory incubator series

One control platform, six chamber capacities
Select MBINE30, MBINE45, MBINE65, MBINE85, MBINE125 or MBINE230 according to sample quantity, vessel dimensions, shelf count and expected door-opening frequency.
MBINE series — model variants and chamber sizes
Choose the MBINE laboratory incubator capacity that matches the usable chamber volume, shelf count and sample load required by the method.
MBINE30
SKU: PRO3362
Volume: 30 L
Power: 0.4 kW / 1.8 A
Internal: 310 × 310 × 310 mm
External: 460 × 510 × 695 mm
Shelves: 2 (max. 5)
Net weight: 33 kg
MBINE45
SKU: PRO3441
Volume: 45 L
Power: 0.5 kW / 2.3 A
Internal: 350 × 350 × 350 mm
External: 500 × 550 × 735 mm
Shelves: 2 (max. 6)
Net weight: 37 kg
MBINE65
SKU: PRO3442
Volume: 65 L
Power: 0.7 kW / 3.2 A
Internal: 400 × 360 × 450 mm
External: 550 × 550 × 840 mm
Shelves: 2 (max. 8)
Net weight: 44 kg
MBINE85
SKU: PRO3363
Volume: 85 L
Power: 0.9 kW / 4.1 A
Internal: 450 × 420 × 450 mm
External: 590 × 610 × 830 mm
Shelves: 2 (max. 8)
Net weight: 50 kg
MBINE125
SKU: PRO3443
Volume: 125 L
Power: 1.1 kW / 5 A
Internal: 500 × 450 × 550 mm
External: 636 × 680 × 915 mm
Shelves: 2 (max. 11)
Net weight: 60 kg
MBINE230
SKU: PRO3444
Volume: 230 L
Power: 1.5 kW / 6.8 A
Internal: 600 × 500 × 750 mm
External: 735 × 835 × 1115 mm
Shelves: 2 (max. 17)
Fan: fixed speed
Net weight: 94 kg
Technical specifications
Compare every MBINE laboratory incubator model using the manufacturer temperature, chamber, shelf, dimensional and electrical specifications below.
| Parameter | MBINE30 | MBINE45 | MBINE65 | MBINE85 | MBINE125 | MBINE230 |
|---|---|---|---|---|---|---|
| SKU | PRO3362 | PRO3441 | PRO3442 | PRO3363 | PRO3443 | PRO3444 |
| Chamber volume | 30 L | 45 L | 65 L | 85 L | 125 L | 230 L |
| Temperature range | RT+5 to 120 °C | |||||
| Resolution / fluctuation / uniformity | 0.1 °C / ±1 °C / ±1.0 °C | |||||
| Control mode / sensor | Two-section intelligent PID, sensor-deviation correction, overshoot self-tuning / Pt100 | |||||
| Air circulation | Forced convection: vertical double-duct supply, horizontal circulation | |||||
| Fan speed | 3 adjustable | 3 adjustable | 3 adjustable | 3 adjustable | 3 adjustable | fixed |
| Setting / display / timer | Touch buttons / LCD (measured upper row, set lower row) / 0–9999 min with timing-wait function | |||||
| Inner chamber / heater | Mirror-polished stainless steel / stainless-steel heating tube | |||||
| Outer shell / insulation | Cold-rolled steel with electrostatic coating / high-quality foam board | |||||
| Door / exhaust hole | Double-layer door with tempered glass window / φ35 mm on top with test-hole function | |||||
| Safety devices | Heating cut-off with red LED above alarm value; independent digital temperature limiter; sound-light alarm | |||||
| Shelves standard / max. | 2 / 5 | 2 / 6 | 2 / 8 | 2 / 8 | 2 / 11 | 2 / 17 |
| Load per shelf / shelf pitch | 15 kg / 40 mm | |||||
| Power / current (220 V, 50/60 Hz) | 0.4 kW / 1.8 A | 0.5 kW / 2.3 A | 0.7 kW / 3.2 A | 0.9 kW / 4.1 A | 1.1 kW / 5 A | 1.5 kW / 6.8 A |
| Internal W × L × H | 310 × 310 × 310 mm | 350 × 350 × 350 mm | 400 × 360 × 450 mm | 450 × 420 × 450 mm | 500 × 450 × 550 mm | 600 × 500 × 750 mm |
| External W × L × H | 460 × 510 × 695 mm | 500 × 550 × 735 mm | 550 × 550 × 840 mm | 590 × 610 × 830 mm | 636 × 680 × 915 mm | 735 × 835 × 1115 mm |
| Packing W × L × H | 540 × 575 × 855 mm | 580 × 615 × 895 mm | 635 × 625 × 995 mm | 680 × 685 × 1000 mm | 710 × 730 × 1100 mm | 857 × 885 × 1287 mm |
| Net / gross weight | 33 / 37 kg | 37 / 43 kg | 44 / 49 kg | 50 / 56 kg | 60 / 66 kg | 94 / 120 kg |
The MBINE laboratory incubator control system combines daily operating functions with temperature correction, alarms and sample observation.
Operating and temperature-control functions
Two-section PID control
Two-section intelligent PID with a Pt100 sensor, sensor-deviation correction and overshoot self-tuning keeps the setpoint within ±1 °C.
Air circulation and fan speed
A vertical double-duct supply circulates air horizontally through the chamber; three adjustable fan speeds with LED running indicator adapt air movement to plates, flasks or sensitive samples (MBINE230 runs at a fixed fan speed).
LCD controller, timer and memory
Touch-button setting with measured and set temperature on two LCD rows; 0–9999 min timer with timing-wait function, auto stop, parameter locking and parameter memory after a power cut.
Alarm and observation
Over-temperature sound and light alarm; the tempered glass window allows visual inspection without opening the door.
Temperature safety, chamber design and test-hole access
Layered protection
When the chamber temperature exceeds the alarm value, a red LED lights and the heating circuit is cut off; a high-precision independent digital temperature limiter adds a second, separate layer of protection.
Mirror stainless chamber and double-layer door
The mirror-polished stainless-steel chamber with stainless heating tube is easy to clean; the double-layer door with tempered glass window and foam-board insulation limit heat loss during visual checks.
Exhaust flap and shelves
The φ35 mm exhaust hole on top doubles as a test hole for external probes; two shelves rated up to 15 kg each are included, with a 40 mm shelf pitch and a frame for four positions.
Standard delivery and options
Typical standard delivery
Selected MBINE incubator, two shelves on a four-position frame, LCD controller, standard temperature certificate at 40 °C in the chamber centre issued by COLO technical service, and standard documentation.
Options
Additional shelves, USB (U-disk) data storage, printer, 3.5″ colour touch-screen temperature controller and one- or multi-point temperature mapping by an accredited laboratory. Availability is confirmed in the quotation.
PRODUCT SELECTION
Incubation catalogue
Compare MBINE with other laboratory incubation solutions.
TECHNICAL DOCUMENT
MBINE technical specification
Open the online specification or download the matching PDF.
INTERNATIONAL WEBSITE
COLO.Science
Visit the COLO.Science international website for laboratory equipment knowledge and product information.
A properly selected MBINE laboratory incubator supports repeatable work across routine laboratory applications.
Applications and operational value
Microbiological cultivation
Stable forced-air incubation for bacteria cultivation and microbial testing.
Stability and QC testing
Repeatable conditions for pharmaceutical, industrial and food quality-control work.
Flexible chamber sizing
Six volumes from 30 to 230 L allow capacity to follow the current sample load.
Verification support
Sensor-deviation correction, standard certificate and a φ35 mm test hole for external probes support checking procedures.
How to select the appropriate MBINE model
Select the MBINE laboratory incubator by starting with the required usable chamber volume, the number of shelves and the dimensions of vessels. Allow space around samples for effective forced-air circulation. MBINE30 and MBINE45 suit compact routine loads, MBINE65 and MBINE85 provide mid-size general laboratory capacity, and MBINE125 and MBINE230 support larger batches and taller vessels; MBINE230 runs at a fixed fan speed while all other models offer three speeds. Compared with other COLO incubators, MBINE is the forced-convection series with a 120 °C upper limit, while MBIND uses natural convection, MBINF adds UV sterilisation and MBINT offers TFT touch control with ±0.2 °C at 37 °C.
Also define the target setpoint, ambient conditions, preferred fan-speed step, door-opening frequency, certificate or mapping requirement, external-probe use, data interface needs and electrical supply.
MBINE forced-air laboratory incubators with 30 L to 230 L chambers
MBINE laboratory incubators are designed for laboratories that require controlled above-ambient incubation up to 120 °C, forced-air circulation and practical LCD operation. The six models share the same control platform while providing a wide choice of chamber capacity, shelf count and footprint.
The series combines two-section intelligent PID regulation, a Pt100 sensor, three-speed fan control, a 0–9999 min timer, a mirror-polished stainless-steel chamber, a double-layer door with tempered glass window, a φ35 mm exhaust hole with test-hole function, over-temperature heating cut-off and an independent digital temperature limiter.
Configuration notice
Each MBINE laboratory incubator may be supplied in a different configuration depending on the selected model, voltage, chamber capacity, shelves, options, documentation and certificate requirements. The official quotation defines the final delivery scope. Website content is intended for general product presentation and may not represent the exact delivered configuration. Specifications may change without notice.