MBINC Refrigerated Incubator, 70 to 250 L, 0 to 65 °C and −10 to 65 °C, BOD


COLO.Science · Refrigerated Incubator

70 · 150 · 250 L · 0 to 65 °C · −10 °C (MBINCD) · 30-step program · BOD touch screen

2.850,00€

COLO.Science · Incubation & Controlled Environments · Refrigerated Incubator

MBINC Refrigerated Incubator · 70 to 250 L · 0 to 65 °C and −10 to 65 °C

The refrigerated incubator MBINC holds a stable temperature below and above room temperature, from 0 °C (−10 °C in MBINCD) up to 65 °C. Each of the four versions — basic MBINCA, programmable MBINCC, low-temperature MBINCD and MBINCBOD with a touch screen for BOD tests — comes in 70, 150 and 250 L.

Models and order codes

Version Temperature Control 70 L 150 L 250 L
MBINCA
Basic
0 to 65 °C LCD, timer MBINCA70
PRO2925
MBINCA150
PRO2926
MBINCA250
PRO2927
MBINCC
Programmable
0 to 65 °C LCD, 30-step program MBINCC70
PRO3098
MBINCC150
PRO3127
MBINCC250
PRO3128
MBINCD
Low temperature
−10 to 65 °C Colour LCD, 30-step program MBINCD70
PRO3445
MBINCD150
PRO3446
MBINCD250
PRO5100
MBINCBOD
BOD, touch screen
0 to 65 °C 5.0-inch touch screen, 30-step program MBINCBOD70
PRO3450
MBINCBOD150
PRO3449
MBINCBOD250
PRO3448

All twelve models heat and cool with a CFC-free compressor, circulate the air with a fan and have an inner glass door. MBINCD and MBINCBOD use a larger high-precision cabinet with up to 9, 12 or 18 shelves.

Refrigerated incubator for microbiology, BOD tests and storage

A CFC-free compressor and a heater work together under a PID controller, so the set point holds also near and below room temperature, where a heating-only incubator cannot work. A fan circulates the air for an even temperature on every shelf, and automatic defrosting keeps the evaporator free of ice during long runs. Through the inner glass door you can check the samples without losing the temperature.

MBINC refrigerated incubator with compressor unit and control panel

Key features

  • Chamber 70, 150 or 250 L, stainless steel, adjustable shelves
  • 0 to 65 °C, or −10 to 65 °C in MBINCD; fluctuation ±0.5 °C
  • Heating and cooling with a CFC-free compressor (R134a)
  • Forced air circulation with fan, interior light, side access port
  • 30-step program of temperature and time (MBINCC, MBINCD, MBINCBOD)
  • Automatic defrost and independent temperature limiter (MBINCC, D, BOD)
  • 5.0-inch touch screen in MBINCBOD
  • Inner tempered glass door, outer door with magnetic seal, casters

Suitable for

  • Microbiology at 20–37 °C in warm laboratories
  • BOD₅ tests at 20 °C in water and wastewater laboratories
  • Storage of samples, media and reagents at 4–8 °C
  • Stability tests and programmed cooling and warming cycles, down to −10 °C with MBINCD

Which version do you need?

Choose MBINCA for a fixed set point with a timer, MBINCC when the temperature must change in steps, MBINCD when you work below 0 °C, and MBINCBOD for BOD tests and long programmed runs with a touch screen. MBINCD and MBINCBOD have a larger high-precision cabinet that takes up to 9, 12 or 18 shelves.

For work only above room temperature see the MBINF forced-air incubators; for shaking with cooling see the ORSHA80 · ORSHA85 vertical shaking incubators.

Technical specifications

Temperature and control

Temperature 0 to 65 °C · −10 to 65 °C (MBINCD)
Fluctuation ±0.5 °C (±1 °C below RT)
Uniformity ±1 °C
Resolution 0.1 °C
Program 30 steps (C, D, BOD)
Timer 1–9999 min

Cooling and size

Volume 70 · 150 · 250 L
Cooling compressor, R134a
Air circulation forced, with fan
Display LCD · colour LCD · touch screen
Power 0.3 to 1.2 kW
Supply 220 V, 50 Hz

Typical values, measured without load at 5–30 °C ambient. RT = room temperature. Dimensions and weights of each model are in the PDF.

Installation and care

Place the incubator on a level floor with at least 10 cm of free space behind and at the sides, so the condenser can release heat, and keep the room between 5 and 30 °C. Leave space between bottles and plates for the air. Below room temperature keep the door closed as much as possible; automatic defrosting removes ice from the evaporator.

Standard delivery and options

  • Refrigerated incubator in the chosen version and size, with two stainless steel shelves.
  • Interior light and side access port.
  • Option: extra shelves, RS485 interface, printer.
  • Option: temperature certificate at a chosen point.

The configuration for a specific order is the one confirmed in the COLO.Science quotation.

Technical documents and knowledge base

MBINC technical specification (PDF) — all four versions in 70, 150 and 250 L, with dimensions, features by version and configuration checklist. Methods and application notes: our knowledge base.

Configuration note

Tell us the temperature, the method and the number of samples. COLO.Science will confirm the version and the size in the quotation.

Sales and support for international customers

COLO Lab ExpertsPolje ob Sotli 4, SI-3255 Buče, Slovenia
Phone: +386 70 713 437 · Email: sales@colo.si · Web: colo.si
We supply laboratories across Europe directly and through partners. B2B prices are quoted net, excluding VAT.

Which version and size fit your lab?

Send the temperature, the method and the number of samples. COLO.Science will confirm the model and the delivery time.

SKU: MBINC Categories: , Tag:
Incubators

, ,

,