Two Shops
One Shipment

ALEMADR-MSC Laboratory Dry Block Thermo Shaker Incubator


COLO.Science · Heating / Cooling Thermo Shaker Incubator

ALEMADR-MSC is a compact heating and cooling thermo shaker incubator for controlled incubation, Peltier cooling and orbital mixing of tubes, PCR formats, microplates and interchangeable thermo blocks.

–20–100°C · 0–1500 rpm · Peltier cooling · SKU PRO3907

1.250,00

COLO.Science — HEATING / COOLING THERMO SHAKER INCUBATOR — ALEMADR-MSC

ALEMADR-MSC Thermo Shaker Incubator –20°C to 100°C

ALEMADR-MSC Thermo Shaker Incubator is a compact laboratory dry block thermo shaker with heating, cooling and orbital mixing functions. With a temperature control range from –20°C to 100°C, 0–1500 rpm mixing speed, 2 mm orbit, Peltier cooling, PID temperature control, two-line LCD display and brushless DC motor, ALEMADR-MSC is suitable for temperature-sensitive sample preparation, molecular biology workflows, enzyme reactions, PCR-related protocols, tube incubation and controlled mixing at sub-ambient or elevated temperatures.

Thermo shaker incubator
–20°C to 100°C
0–1500 rpm
2 mm orbit
Peltier cooling
PID control
SKU PRO3907

COLO.Science ALEMADR-MSC thermo shaker incubator with cooling SKU PRO3907 main unit

COLO.SCIENCE — SAMPLE PREPARATION / COOLING DRY-BLOCK THERMO SHAKERS

Heating and cooling thermo shaker incubator for sub-ambient sample workflows

The ALEMADR-MSC Thermo Shaker Incubator is designed for laboratories that require both controlled heating and active cooling in the same compact bench-top system. Unlike heating-only thermo shaker models, ALEMADR-MSC includes Peltier cooling and can support protocols requiring sub-ambient temperature control down to –20°C.

The instrument combines dry-block temperature control, orbital mixing and timed operation. It can be configured with interchangeable thermo blocks for microtubes, centrifuge tubes, PCR formats, microplates, Falcon tubes and deep-well plate workflows. Final block selection should be matched to vessel format, sample volume, temperature range and required shaking speed.

Key features

  • Heating and cooling thermo shaker incubator for temperature-controlled sample workflows.
  • Temperature range –20°C to 100°C with Peltier cooling for sub-ambient applications.
  • 0–1500 rpm mixing speed with 2 mm orbital amplitude.
  • PID temperature control with 0.1°C resolution and stable thermal performance.
  • Two-line LCD display showing set and current temperature, speed and time.
  • Brushless DC motor with soft start, maintenance-free operation and speed stability.

Suitable for

  • Incubation and mixing of DNA, RNA and protein samples in microtubes.
  • Enzyme reactions, restriction digests and ligations requiring temperature control and agitation.
  • Sample preparation for PCR, qPCR and sequencing workflows.
  • Cell lysis, extraction and denaturation protocols in molecular biology.
  • Immunoassays and biochemical assays in tubes or plates.
  • Clinical, pharmaceutical, industrial and quality control laboratory workflows.

TECHNICAL SPECIFICATIONS — ALEMADR-MSC THERMO SHAKER INCUBATOR

Model ALEMADR-MSC
Product type Heating / cooling thermo shaker incubator with dry-block platform
SKU PRO3907
Temperature control range –20°C to 100°C
Cooling system Yes — Peltier cooling
Mixing speed 0–1500 rpm
Mixing amplitude / orbit 2 mm orbital motion
Speed accuracy ±1 rpm
Temperature resolution / display accuracy 0.1°C / ±0.1°C
Temperature stability ±0.1°C typical
Temperature uniformity ±0.5°C at 4°C; ±0.1°C at 37°C; ±0.3°C at 100°C
Heating / cooling performance ≤5 min from 25°C to 100°C; ≤8 min from 100°C to 25°C; ≤8 min from 25°C to –20°C
Timer / continuous operation 1 min to 99 h 59 min or continuous; up to 240 h continuous operation
Display Two-line LCD showing set / current temperature, shaking speed and time
Drive & motor Multidimensional drive with brushless DC motor; soft start and speed protection
Safety functions Overheating and overload protection, power failure memory, program recovery, menu lock and interval mixing
Working ambient temperature +4°C to 40°C
Temperature sensor Pt100, Class A
Power supply AC110–220V±10%, 50/60Hz / approx. 60W · output DC12V / 4.9A
Dimensions W×D×H Approx. 220 × 240 × 90 mm
Net / gross weight Approx. 3.7 / 6 kg
HTML TechSpec Open ALEMADR technical specification

The upper limit of temperature and oscillation speed depends on the selected thermo block. Final compatibility should be confirmed according to sample vessel format, block type, temperature requirement, filling volume and shaking speed.

Interchangeable thermo block options

ALEMADR-MSC uses interchangeable thermo blocks to adapt the same heating and cooling thermo shaker platform to different vessels and plate formats. Available block configurations support PCR formats, microplates, centrifuge tubes, Eppendorf tubes, Falcon tubes and deep-well plate workflows. Maximum operating temperature and maximum rpm are block-dependent.

COLO.Science ALEMADR-MSC K L J M interchangeable thermo blocks

K / L / J / M blocks

Tube, plate and deep-well format support.

COLO.Science ALEMADR-MSC F H G I thermo blocks for tube and Falcon tube formats

F / H / G / I blocks

Tube, Falcon tube and slot module formats.

COLO.Science ALEMADR-MSC A C B E thermo blocks for PCR plates and centrifuge tubes

A / C / B / E blocks

PCR, microplate and centrifuge tube formats.

COLO.Science ALEMADR-MSC additional thermo block configuration reference

Additional block reference

Visual reference for block configuration planning.

COLO.SCIENCE KNOWLEDGE

Learn more about thermo shaker incubators in practice

Explore COLO.Science resources covering dry block incubators, thermo shakers and sample preparation workflows for molecular biology, clinical diagnostics and quality control.


Read on COLO.Science →

Applications and laboratory value

Sub-ambient incubation and mixing

ALEMADR-MSC is suitable for workflows where samples must be mixed or held below room temperature before, during or after heating steps.

DNA, RNA and protein workflows

Heating, cooling and orbital mixing support molecular biology sample preparation, including extraction, denaturation and controlled reaction steps.

PCR and microplate support

Optional thermo blocks allow use with PCR tubes, PCR plates, microplates and enzyme-labeled plate formats when compatible conditions are confirmed.

Clinical, QC and research laboratories

The compact footprint, cooling option, LCD operation and modular block system make ALEMADR-MSC useful for intensive daily laboratory work.

How to choose the correct ALEMADR-MSC configuration

When selecting a cooling thermo shaker incubator, the laboratory should define whether the protocol requires sub-ambient cooling, elevated-temperature incubation, orbital mixing or a combination of all three functions. ALEMADR-MSC is the heating / cooling thermo shaker model in the ALEMADR family and should be selected when controlled cooling down to –20°C and mixing up to 1500 rpm are required.

The selected thermo block determines practical compatibility, maximum temperature, maximum rpm and supported vessel format. Before quotation, COLO.Science recommends confirming sample vessel type, tube diameter, working volume, target temperature, shaking speed, protocol duration and whether cooling recovery time is important for the workflow.

ALEMADR-MSC as a cooling thermo shaker incubator for daily laboratory work

ALEMADR-MSC Thermo Shaker Incubator is useful when a laboratory needs one compact system for heating, cooling and reproducible orbital mixing. Instead of using a separate dry bath, laboratory shaker and cooling block, the user can run temperature-controlled incubation, reagent mixing and small-volume sample preparation in one dry-block platform.

The –20°C to 100°C temperature range makes ALEMADR-MSC suitable for protocols that move between cold holding, controlled warming and higher-temperature incubation. Combined with 0–1500 rpm mixing speed and a 2 mm orbit, the instrument supports workflows where stable temperature and repeatable mixing are important for consistency. The correct thermo block selection allows the device to be adapted to real laboratory vessels and application requirements.

Configuration notice — instruments are delivered according to application requirements

Cooling thermo shaker incubators are typically selected according to temperature range, cooling requirement, mixing speed, sample vessel format, thermo block type, filling volume and workflow requirements.
Available configurations, compatible thermo blocks and technical options should be confirmed before quotation.
The content shown on this website is provided for general information and may not represent the final delivered configuration.

ALEMADR-MSC — compact heating and cooling thermo shaker incubator for tubes and plates

A compact thermo shaker incubator for controlled heating, Peltier cooling and orbital mixing — with –20°C to 100°C temperature range, 0–1500 rpm mixing speed, 2 mm orbit, PID control, interchangeable thermo blocks and support from COLO.Science.

Incubarots

, , ,

,