NOVEL2 touch screen Vis spectrophotometer series — 325–1000 nm, automatic wavelength
The NOVEL2 touch screen Vis spectrophotometer series brings automatic wavelength setting and on-board methods to routine visible-range work. Both models cover 325–1000 nm with a 4 nm spectral bandwidth, measure up to 4 A and are operated from a 7″ colour touch screen. NOVEL2 measures at fixed wavelengths, in kinetics and by regression; NOVEL2S also scans the spectrum.
Which UV/Vis spectrophotometer?
Vis — teaching and routine
Single and split beam — routine Vis and UV/Vis
Double beam, variable bandwidth and PMT
Automatic wavelength and methods on the instrument
With a manual instrument every wavelength change is a turn of the knob and a new blank. A touch screen Vis spectrophotometer with automatic wavelength setting keeps the method on the instrument: wavelength, standards, regression and kinetics are set once and repeated with the same accuracy (±1 nm). NOVEL2 is the step between the basic MAVRICA-V series and the NOVEL3S with 2 nm bandwidth and 8-cell changer.

Key characteristics
- Split beam optics with Czerny-Turner monochromator, holographic grating 1200 lines/mm, 160 mm focal length and silicon photocell detector.
- Automatic wavelength setting from the touch screen — accuracy ±1 nm, repeatability ≤0.5 nm.
- Tungsten-halogen lamp 12 V / 20 W with lifetime protection; automatic 0 A / 100 %T and T/A changeover.
- Methods on the instrument: T, A and concentration, concentration factor, linear regression, kinetics (time scan), timed printing.
- 7″ colour touch screen; measured data, regression equations and calibration are kept after switching off.
- USB port for PC connection; PC software and built-in thermal printer available as options.
Suitable for
- Medical and clinical laboratories with photometric tests
- Water, wastewater and environmental testing
- Biochemistry and enzyme kinetics in the visible range
- Food, beverage and agricultural laboratories
- Quality control, teaching and research laboratories
Models in the series
Both models have the same optics, photometry and touch screen; NOVEL2S adds wavelength scanning.
NOVEL2 touch screen Vis spectrophotometer — model comparison
| Parameter | NOVEL2 | NOVEL2S |
|---|---|---|
| Best for | Routine fixed-wavelength, kinetic and concentration methods with automatic wavelength setting | Like NOVEL2, plus wavelength scanning to find the absorption maximum and check spectra |
| Differences between models | ||
| Wavelength scanning | — | Yes · fast / medium / slow |
| Peak / valley detection on spectrum | — | Yes |
| Baseline flatness · baseline drift | — | ≤±0.002 A · ≤0.003 A/h at 500 nm |
| Common to all models | ||
| Included in standard delivery | 4 × glass cuvette, 10 mm · cell holder 10 mm (PC software and printer are options) | |
| Optical system | Split beam, Czerny-Turner, grating 1200 lines/mm, focal length 160 mm, silicon photocell | |
| Light source | Tungsten-halogen lamp 12 V / 20 W with lifetime protection | |
| Wavelength range · spectral bandwidth | 325–1000 nm · 4 nm | |
| Wavelength setting · accuracy · repeatability | Automatic · ±1 nm · ≤0.5 nm | |
| Stray light at 360 nm (NaNO₂) | ≤0.1 %T | |
| Photometric range | 0–200 %T · −0.301–4.000 A · 0–9999 C | |
| Photometric accuracy | ±0.5 %T · ±0.004 A (0–0.5 A) · ±0.008 A (0.5–1 A) | |
| Photometric repeatability | ≤0.2 %T · 0.002 A (0–0.5 A) · 0.004 A (0.5–1 A) | |
| Noise | ≤0.2 %T at 100 %T · ≤0.1 %T at 0 %T | |
| Functions | T · A · C, concentration factor, linear regression, kinetics, timed printing | |
| Display · interface | 7″ colour LCD touch screen · USB | |
| Sample compartment | Cell holder 10 mm standard; 50 mm and 100 mm holders as options | |
| Power · packing size / gross weight | 100 W · 630 × 510 × 500 mm / 25 kg | |
Power supply AC 220 V ±22 V, 50 Hz ±1 Hz. Conformity: CE.
Why a touch screen Vis spectrophotometer with automatic wavelength
Automatic wavelength setting removes the most common error of basic instruments — a wrongly set knob — and makes multi-step methods practical. The NOVEL2 touch screen Vis spectrophotometer stores regression curves and calibration after switching off, so a method prepared once is ready the next day. With NOVEL2S the absorption maximum of a new colour reaction is found with a scan instead of point-by-point measurement.
For a basic manual instrument with software included choose the MAVRICA-V series; for 2 nm bandwidth and an automatic 8-cell changer choose NOVEL3S.
Standard delivery
- Instrument: NOVEL2 or NOVEL2S spectrophotometer
- Cell holder: 10 mm
- Cuvettes: 4 × glass cuvette, 10 mm path length
- Cables and spares: Power cable · 2 fuses
- Documents: Operation manual
Options: PC software, built-in thermal printer, 50 mm and 100 mm cell holders, additional cuvettes — confirmed in the COLO.Science quotation.
Knowledge base
Detailed data for both models are in the NOVEL2 technical specification (PDF). Spectral bandwidth, stray light, the Beer–Lambert law and cuvette selection are explained on COLO.Science, our knowledge platform.
Selection guide
- Fixed wavelength, kinetics, concentration: NOVEL2.
- You also need the spectrum (absorption maximum, spectrum check): NOVEL2S.
- Manual operation, lowest cost, software included: MAVRICA-V series.
- 2 nm bandwidth, 8-cell changer or UV range: NOVEL3S or a UV/Vis model.
Configuration notice
This page is provided for orientation and product selection. Cell holders, cuvettes, printer, software and other options are confirmed with the official COLO.Science quotation.