ALEMADR range
Dry bath incubators
ALEMADR-MBMini · heating to 100 °C
ALEMADR-MB2Mini · to 100 °C · block included
ALEMADR-MCMini · heating/cooling · RT−15–100 °C
ALEMADR-SO1 block · RT+5–100 °C
ALEMADR-SOC1 block · cooling · RT−30–100 °C
ALEMADR-MIDual block · RT+5–100 °C
ALEMADR-MO4 blocks · RT+5–110 °C
ALEMADR-SB1, 2 or 4 blocks · up to 160 °C
ALEMADR-DBAdjustable heated lid · to 100 °CThermo shakers
COLO.Science · Incubation & Controlled Environments · Dry bath incubators
ALEMADR-SOC dry bath incubator with cooling — Peltier, RT−30 °C to 100 °C
The ALEMADR-SOC dry bath incubator heats and cools one interchangeable aluminium block with a Peltier element. The temperature is set from −10 °C to 100 °C and controlled from RT−30 °C to 100 °C, to ≤ ±0.3 °C accuracy and uniformity, and the instrument can hold samples at 4 °C automatically. Programs run up to five temperature points and repeat up to 99 times. Product code PRO4539.
Heating only, or heating and cooling?
Heating and cooling in one dry bath — from below room temperature up to 100 °C
The ALEMADR-SOC dry bath incubator does what a heating-only dry bath cannot: it takes samples below room temperature. A Peltier element heats and cools the same aluminium block, so one instrument holds a ligation at 14 °C, keeps enzymes or libraries at 4 °C at the bench and runs heat steps up to 100 °C.

Key characteristics
- One interchangeable block, eleven block formats, ordered separately.
- Temperature −10 °C to 100 °C setting, RT−30 °C to 100 °C controlled, accuracy ≤ ±0.3 °C.
- Temperature uniformity ≤ ±0.3 °C, display resolution 0.1 °C.
- Heating time ≤ 12 min from 25 °C to 100 °C.
- Peltier cooling — ≤ 10 min from 100 °C to 25 °C, ≤ 25 min from RT to RT−30 °C.
- Automatic 4 °C storage for samples at the bench.
- Programs — up to 5 temperature points, up to 99 cycles; timer 1 min to 99 h 59 min or continuous.
- Automatic functions — auto heating, auto running, auto resume after a power failure; user calibration, fault alarm and over-temperature protection.
Suitable for
- Ligation reactions held at 14 °C and oocytes held at 17 °C.
- Samples, enzymes and DNA libraries kept at ice-bucket temperature at the work station.
- Enzyme reactions and deactivation, PCR sample preparation.
- Chilling or heating samples away from the main laboratory.
- Laboratories that need heating and cooling on one ALEMADR-SOC dry bath incubator.
Why a dry bath incubator with cooling
A heating-only dry bath works from a few degrees above room temperature upward. Anything colder — ligation at 14 °C, storage at 4 °C, a sample that has to be chilled quickly after a heat step — needs an ice bucket or a second instrument. The ALEMADR-SOC dry bath incubator covers both directions on one block, from RT−30 °C to 100 °C.
It shares the dimensions, programs and the eleven blocks with the heating-only ALEMADR-SO, so blocks bought for one fit the other.
Model, product code and blocks
The ALEMADR-SOC dry bath incubator with cooling is supplied as a main unit; the block is chosen separately by tube or plate format and ordered under its own product code. The instrument takes one block at a time. Quote and order with the COLO product code.
ALEMADR-SOC dry bath incubator with cooling, one block, −10 °C to 100 °C setting, RT−30 °C to 100 °C control, blocks ordered separately.

Blocks for microtubes and plates
| PRO4484 | 96 × 0.2 ml PCR plate |
| PRO4483 | 54 × 0.5 ml centrifuge tubes |
| PRO4307 | 35 × 1.5 ml centrifuge tubes |
| PRO4485 | 35 × 2.0 ml centrifuge tubes |
| PRO4486 | 20 × 1.5 ml + 15 × 0.5 ml |
| PRO4487 | 96-well ELISA plate |
Blocks for larger tubes
| PRO4488 | 24 × 5 ml tubes |
| PRO4489 | 15 × 10 ml tubes |
| PRO4490 | 12 × 15 ml tubes |
| PRO4491 | 6 × 50 ml tubes, round bottom |
| PRO4308 | 6 × 50 ml tubes, conical bottom |
Same blocks fit
| ALEMADR-SO | Dry bath incubator, heating |
| ALEMADR-SOC | Dry bath incubator, heating and cooling |
| ALEMADR-MS · ALEMADR-MSC | Thermo shakers |
Technical specifications
Programs, safety and general data
| Timer | 1 min – 99 h 59 min, or continuous |
| Multi-point program | Up to 5 points |
| Program cycles | Up to 99 |
| Auto heating · auto running | Yes · Yes |
| Auto resume after power failure | Yes |
| Temperature calibration | User calibration |
| Safety | Fault detection, buzzer alarm, over-temperature protection, CE |
| Power | 150 W |
| Supply voltage | AC 100–240 V, 50/60 Hz |
| Fuse | 250 V, 3 A, Ø 5 × 20 |
| Dimensions and weight | 260 × 195 × 150 mm · 4.5 kg |
| Product code | PRO4539 |
Temperature and block
| Temperature setting range | −10 °C to 100 °C |
| Temperature control range | RT−30 °C to 100 °C |
| Temperature accuracy | ≤ ±0.3 °C |
| Temperature uniformity | ≤ ±0.3 °C |
| Display resolution | 0.1 °C |
| Heating time | ≤ 12 min, from 25 °C to 100 °C |
| Cooling time | ≤ 10 min, 100 °C to 25 °C · ≤ 25 min, RT to RT−30 °C |
| Automatic 4 °C storage | Yes |
| Heating and cooling | Peltier element |
| Block positions | 1 interchangeable block |
| Display | LCD |
Operating functions
Temperature
The ALEMADR-SOC dry bath incubator is set from −10 °C to 100 °C and controlled from 30 degrees below room temperature up to 100 °C, with 0.1 °C on the display and ≤ ±0.3 °C accuracy and uniformity. It cools from 100 °C to 25 °C in about ten minutes and from room temperature to RT−30 °C in about 25 minutes; the AUTO 4 °C function keeps samples cold after a run.
Programs and timer
A program holds up to five temperature points, each with its own time, and repeats up to 99 times. The timer runs from one minute to 99 hours 59 minutes, or continuously, and a buzzer signals the end of the temperature control.
Automatic functions and calibration
Auto heating and auto running are built in, and after a power failure the instrument resumes the run when the supply returns. The user calibration function lets the temperature be set to an in-house standard.
Build, power supply and safe operation
The ALEMADR-SOC dry bath incubator is a mains-powered benchtop instrument: 150 W, AC 100–240 V at 50/60 Hz, protected by a 250 V 3 A fuse (Ø 5 × 20). Heating and cooling come from a Peltier element under the block. Control is microprocessor-based, with fault detection, a buzzer alarm and built-in over-temperature protection; the instrument carries the CE mark.
It measures 260 × 195 × 150 mm and weighs 4.5 kg. Confirm the plug type for the country of use before the order is placed.
Standard delivery
- Main unit of the ALEMADR-SOC dry bath incubator with cooling.
- Mains cable.
- Operating manual.
- Declaration of conformity and warranty documentation.
The block is not part of the main unit — it is ordered separately under its own product code, according to the tube or plate format. The delivered configuration for a specific order is the one confirmed in the COLO.Science quotation.
Knowledge base
Dry bath incubators on COLO.Science — our knowledge base.
Applications and operational value
The ALEMADR-SOC dry bath incubator is used where samples move between cold and warm: ligation at 14 °C, oocytes at 17 °C, enzymes and DNA libraries kept cold at the bench, enzyme reactions and deactivation, PCR sample preparation and chilling or heating samples in the field.

Microtube blocks take 0.2 ml to 2.0 ml tubes, including a mixed 1.5 ml and 0.5 ml block; tube blocks take 5, 10, 15 and 50 ml tubes, the 50 ml in round or conical bottom; plate blocks take a 0.2 ml PCR plate or a 96-well ELISA plate.
Against a water bath the argument is the usual one for dry heat — no water to change and no contamination path. Against an ice bucket, the temperature is set and held, not estimated.
Selection guide
- Heating only, or heating and cooling? Above room temperature the ALEMADR-SO is enough; at or below room temperature, or for 4 °C storage, choose the ALEMADR-SOC.
- Tube or plate format. One block per instrument — choose from the eleven formats and count the positions per run.
- More samples or several temperatures? Two independent zones: ALEMADR-MI; four blocks with four timers: ALEMADR-MO.
- Shaking or a heated lid? The same blocks fit the ALEMADR-MS and ALEMADR-MSC thermo shakers; for a heated lid choose the ALEMADR-DB.
- Mains voltage. AC 100–240 V; confirm the plug type for the country of use.
Configuration notice
This page is provided for orientation and product selection. It does not replace the binding specification, the delivered configuration, the validation protocol or the acceptance criteria confirmed in the official COLO.Science quotation, proforma invoice or order confirmation. Confirm the tube or plate format, the block and the mains voltage version of the ALEMADR-SOC dry bath incubator with cooling for the specific order. B2B prices are quoted net, excluding VAT.
Sales and support for international customers
COLO Lab ExpertsPolje ob Sotli 4, SI-3255 Buče, Slovenia
Phone: +386 70 713 437 · Email: sales@colo.si · Web: colo.si
We supply laboratories across Europe directly and through partners. B2B prices are quoted net, excluding VAT.