CM3005 Multi-Angle Spectrophotometer, 5 Angles


COLO.Science · Multi-angle spectrophotometer

5 angles · 45° receiver · flop index · 400–700 nm · ΔE*ab 0.03 · camera

COLO.Science · Spectroscopy & Color · Multi-angle colour measurement

CM3005 Multi-Angle Spectrophotometer — 5 angles for metallic and effect finishes

The CM3005 multi-angle spectrophotometer (COLO product code PRO7922) measures the colour of metallic, pearlescent and other special-effect finishes at 5 angles in one measurement, with 1 receiver (45°). It is a handheld, battery-powered instrument for the car body, the paint shop, the production line and the laboratory.

Overview

Place the instrument on the panel and press the button: all 5 angles are measured in about 5 s and shown in one table on the touch screen, with the colour difference to the standard at every angle and a pass/fail result.

CM3005 handheld multi-angle spectrophotometer with touch screen

Key characteristics

  • 5 measuring angles in one measurement, 1 receiver (45°)
  • Concave grating and 256-pixel dual-array CMOS sensor, 400–700 nm in 10 nm steps, 0–600 % reflectance
  • Full-spectrum LED with blue enhancement
  • Repeatability ΔE*ab 0.03, inter-instrument agreement 0.2 ΔE*00
  • Flop index and colour difference at every angle
  • Colour camera preview, 3.5″ touch screen, USB and Bluetooth 5.0, battery operation

Suitable for

  • Automotive OEM coatings: body colours, bumpers, mirror caps and other add-on parts matched to the body
  • Refinish and body repair: the repair colour checked against the original paint at every angle
  • Paint and effect-pigment producers: aluminium, mica and interference pigments in development and incoming inspection
  • Coated plastics and consumer goods with metallic or pearlescent finish

Why multi-angle

A metallic or pearlescent coating does not have one colour: near the gloss angle it is light and saturated, at the face angle it shows its main colour, and at a flat angle (the flop) it turns darker or changes hue. Two panels can match at 45° and still look different on the car. A multi-angle instrument measures every angle the standard prescribes, so a mismatch is found before the parts are assembled. The CM3005 measures the five angles used in the ASTM and DIN methods for metallic finishes.

On the instrument

Flat and curved samples

Flat and curved samplesPanels, test cards and curved body parts under one wide measuring port.
Camera preview

Camera previewThe built-in colour camera shows the measured area before the measurement.
Touch-screen operation

Touch-screen operationColour space, illuminant, tolerances and records set on the instrument.
On the car body

On the car body1 kg, battery powered — 6 000 measurements on one charge.

Technical specifications

Optics and performance

Measuring geometry 5 angles, 1 receiver (45°)
Measuring angles 45° receiver: 45as15°, 45as25°, 45as45°, 45as75°, 45as110°
Standards ASTM D2244, E308, E1164, E2194, E2539; DIN 5033, 5036, 6174, 6175-1, 6175-2; ISO 7724, ISO 11664-4; SAE J1545
Light source Full-spectrum LED with blue enhancement; 5 years, 3 million measurements
Optics Concave grating, 256-pixel dual-array CMOS image sensor
Wavelength range 400–700 nm, 10 nm interval
Reflectance range 0–600 %
Measuring aperture Illumination Ø23 mm, spot 9 × 12 mm
Repeatability ΔE*ab 0.03; spectral reflectance SD within 0.08 %
Reproducibility ΔE* < 0.10 grey BCRA tile; < 0.25 colour BCRA tiles
Inter-instrument agreement 0.2 ΔE*00 (BCRA Series II tiles)

Colour data and general

Colour spaces CIE Lab, XYZ, Yxy, LCh, βxy, DIN Lab99
Colour difference ΔE*ab, ΔE*94, ΔE*cmc (2:1 and 1:1), ΔE*00, DIN ΔE99, ΔE DIN 6175
Other indices Flop index
Observer 2° and 10°
Illuminants D65, A, C, D50, D55, D75, F1–F12 (incl. CWF, DLF, TPL5, TL84, TL83/U30)
Measuring time approx. 1 s per angle, approx. 5 s for all angles
Measurement modes Single, average 1–99, continuous 1–99; button or software trigger
Positioning · display Colour camera preview · 3.5″ TFT capacitive touch screen
Interface · storage USB, Bluetooth 5.0 · 1 000 standards, 4 000 samples
Calibration White calibration board, black light trap; 4 h, 8 h, 24 h or at start-up
Power Li-ion 3.7 V, 5 000 mAh; 6 000 measurements in 8 h
Dimensions · weight 195 × 83 × 128 mm · approx. 1 kg
Operating environment 10–50 °C, ≤ 85 % RH, non-condensing

Measuring and data

All 5 angles are measured with one press of the button; the camera preview shows where the instrument sits on the part. The instrument keeps 1 000 standards and 4 000 samples and transfers data by USB or Bluetooth 5.0; the PC software is available for download.

Which model in the series?

All models share the same handheld body, concave-grating optics with a 256-pixel CMOS array, 400–700 nm, 0–600 % reflectance, camera preview and a 3.5″ touch screen. They differ in the number of angles and receivers and in the effect values:

CM3003 CM3005 CM3006 CM3008 CM3012
Measuring angles 3 5 6 8 12
Receivers 45° 45° 45° 45° + 15° 45° + 15°
45° receiver angles 25° · 45° · 110° 15° · 25° · 45° · 75° · 110° −15° · 15° · 25° · 45° · 75° · 110° as CM3006 as CM3006
15° receiver angles — — — −15° · 15° −45° · −30° · −15° · 15° · 45° · 80°
Effect values SG · DC · CV — — ✓ ✓ ✓
Repeatability ΔE*ab 0.04 0.03 0.03 0.03 0.02
Inter-instrument ΔE*00 0.2 0.2 0.2 0.18 0.18
All angles ≈ 3 s ≈ 5 s ≈ 6 s ≈ 8 s ≈ 12 s
  • CM3003 — routine check of metallic colours: near-specular, face and flop angle.
  • CM3005 — the five angles of the ASTM and DIN methods for metallic finishes, for paint shops and suppliers of add-on parts.
  • CM3006 — six angles plus sparkle grade, coarseness and colour variation, when the effect pigment itself must be controlled.
  • CM3008 — adds a 15° receiver for pearlescent and interference pigments.
  • CM3012 — twelve angles with two receivers for development laboratories and OEM colour approval.

Standard delivery

  • CM3005 multi-angle spectrophotometer with 3.5″ touch screen and built-in battery
  • White calibration board and black light trap
  • Power adapter, USB cable; PC software available for download
  • Carrying case for transport and storage
  • Protective cap, wrist strap, user guide

The delivered configuration for a specific order is the one confirmed in the COLO.Science quotation.

Knowledge base

New to colour measurement? Light sources, metamerism, CIE Lab, ΔE and measuring geometries — including multi-angle measurement of effect finishes — are explained on COLO.Science, our knowledge base.

Selection guide

  • Metallic, pearlescent and special-effect finishes: the CM30 multi-angle series — see the comparison above.
  • Solid colours with a hand-held 45/0 instrument: the CS45 portable series.
  • Solid colours with d/8 and SCI/SCE: the CS70 portable series.
  • Reflectance and transmittance on the bench: the CS60 benchtop series.

Configuration notice

This page is provided for orientation and product selection. The finish, angles, aperture and the colour data you report are confirmed with the official COLO.Science quotation.

Sales and support for international customers

COLO Lab ExpertsPolje ob Sotli 4, SI-3255 Buče, Slovenia
Phone: +386 70 713 437 · Email: sales@colo.si · Web: colo.si
We supply laboratories across Europe directly and through partners. B2B prices are quoted net, excluding VAT.

Matching metallic or pearlescent colours?