VIKING-EC300 Laboratory Conductivity Meter
Note: Includes PRO6154 EC electrode, 1413 μS/cm standard (50 mL), and EHO5 (PRO6110) electrode stand.
Highlight: IP54 protection, GLP-compliant storage (500 sets per parameter), USB/RS-232 connectivity.
Key Features
- 7.0″ high-resolution LCD with backlight.
- Multi-reading modes: Auto Read (Fast/Medium/Slow), Timed, Continuous.
- Automatic/Manual Temperature Compensation (ATC/MTC); endpoint Auto-Hold with Reading/Stable/Locked prompts.
- GLP-compliant data storage: 500 results for each parameter.
- USB & RS-232 outputs for PC/printer; date & time stamping; auto shutdown 1–60 min (or Off).
- 1–3 point calibration with standard recognition (84 μS/cm, 1413 μS/cm, 12.88 mS/cm).
- Settable cell constant, temperature coefficient, and TDS factor; temp. compensation types (none, linear, pure water).
- IP54 protection.
Included
- 
- PRO6154 EC electrode
 
- 1413 μS/cm EC standard solution, 50 mL (1 vial)
- EHO5 electrode stand (PRO6110)
Specifications
| Parameter | Value | 
|---|---|
| Model | VIKING-EC300 | 
| Measured Parameters | EC / Resistivity / TDS / Salinity / Temperature | 
| Conductivity Range | 0.000 μS/cm ~ 1000 mS/cm | 
| Conductivity Resolution | 0.001 μS/cm minimum (varies by range) | 
| Conductivity Accuracy | ±1.0% FS | 
| Reference Temperature | 20, 25 °C | 
| Calibration Points | Up to 3 (standards recognition at 84 μS/cm, 1413 μS/cm, 12.88 mS/cm) | 
| Resistivity Range | 5.00 Ω·cm ~ 20.00 MΩ·cm | 
| Resistivity Resolution | 0.01 Ω·cm minimum | 
| Resistivity Accuracy | ±1.0% FS | 
| TDS Range | 0.00 ppm ~ 300 ppt | 
| TDS Resolution | 0.01 ppm minimum (varies by range) | 
| TDS Accuracy | ±1.0% FS | 
| Salinity Range | 0.0–80.0 ppt; 0.00–8.00 %NaCl | 
| Salinity Resolution | 0.1 ppt; 0.1% | 
| Salinity Accuracy | ±2 ppt | 
| Temperature Range | −5.0 to 110 °C (23.0 to 230 °F) | 
| Temperature Units | °C, °F | 
| Temperature Resolution | 0.1 | 
| Temperature Accuracy | ±0.2 °C | 
| Reading Modes | Auto Read (Fast/Medium/Slow), Timed, Continuous | 
| Prompts | Reading / Stable / Locked | 
| Temp. Compensation | ATC, MTC; types: none, linear, pure water | 
| Data Storage | 500 results each parameter (GLP features) | 
| Inputs | Conductivity with temp probe, 5-pin aviation connector | 
| Outputs | USB, RS-232 (PC/printer) | 
| Backlight | Yes | 
| Auto Shutdown | 1–60 min, Off | 
| IP Rating | IP54 | 
| Date & Time | Yes | 
| Power | AC adapter, 100–240 V AC input; DC 20 V output | 
| Dimensions (Instrument) | 242 × 195 × 68 mm | 
| Net Weight | 900 g (1.98 lb) | 
| Dimensions (Carton) | 350 × 280 × 220 mm | 
| Shipping Weight | 2.5 kg | 



 
				




There are no reviews yet.