VIKING-M510A Portable Multi-Parameter Meter
Overview
VIKING-M510A by COLO.Science measures pH, ion-selective electrodes (ISE), conductivity (EC) and temperature. It also supports mV/ORP and pX, and it calculates resistivity, TDS and salinity. In short, it is easy to use, fast and highly precise.
Moreover, the 4.3″ color touchscreen speeds up configuration and daily work. Therefore, routine testing becomes quicker and more consistent. In addition, the IP65 housing enables reliable field operation.
General Features
- Multi-reading: auto-read, timed-read, continuous-read.
- Automatic/Manual temperature compensation (ATC/MTC).
- Auto-hold endpoint lock; clear Reading / Stable / Locked prompts.
- GLP data: up to 1000 sets per parameter, with data review/compare/recalculate.
- User, calibration, electrode, method and log management.
- USB communication; auto power-off; factory reset.
- IP65 portable design for field/outdoor measurements.
Measurement Modules
pH / mV / ORP / pX / ISE
pH: 1–8 point calibration with standard recognition; buffer groups USA, NIST, DIN, GB, MERK, JIS; user-defined buffers supported; electrode diagnostics (slope & offset). ORP: EH mode, 1 custom calibration point (relative mV). ISE: 1–8 points, units μg/L to ppb and pX; modes Direct, Standard Addition, Sample Addition and GRAN; built-in methods for F−, Cl−, Br−, I−, NO₃−, BF₄−, NH₄⁺, K⁺, Na⁺, Ca²⁺, Cu²⁺, Pb²⁺, Ag⁺; user-defined method supported.
Conductivity / TDS / Salinity / Resistivity
1–5 point calibration with automatic standard recognition. Set cell constant, reference temperature (5/10/15/18/20/25 °C), temperature coefficient and TDS factor. Temperature compensation: none, linear or pure water.
Applications
Designed for water quality labs, environmental monitoring, industrial process control and on-site inspections. As a result, teams complete routine testing faster and with fewer errors.
Included in the Kit
- 3-in-1 pH composite electrode
- EC electrode
- NIST pH buffers 4.01 / 7.00 / 10.01 (50 mL each)
- 1413 μS/cm EC standard solution (50 mL)
- Electrode holder, silicone rubber case, wristbands
- Touch pen
- Carrying case
Specifications
Model & Parameters
| Parameter | Details |
|---|---|
| Model | VIKING-M510A — pH/EC/ISE/Temp (mV/ORP/pX/Resistivity/TDS/Salinity) |
pH / mV / ORP / pX / ISE
| Parameter | Details |
|---|---|
| pH | Range: −2.000 to 20.000 pH; Resolution: 0.1 / 0.01 / 0.001 pH; Accuracy: ±0.002 pH; Calibration: up to 8 points; Buffer groups: USA, NIST, MERK, JIS, GB, DIN; Slope limit & reminder: Yes; User-defined buffer: Yes. |
| mV / ORP | Range: −2000.00 to 2000.00 mV; Resolution: 0.1 / 0.01 mV; Accuracy: ±0.1 mV or ±0.03%; EH ORP mode: Yes; ORP calibration: 1 custom point (relative mV). |
| pX | Range: −2.000 to 20.000 pX; Resolution: 0.1 / 0.01 / 0.001 pX; Accuracy: ±0.002 pX; Calibration: up to 6 points. |
| ISE | Range: 1.000e−9 to 9.999e+9; Units: mol/L, mmol/L, g/L, mg/L, μg/L, ppm, ppb; Resolution: up to 4 significant digits; Accuracy: ±0.3%; Calibration: up to 8 points. |
Conductivity / Resistivity / TDS / Salinity
| Parameter | Details |
|---|---|
| Conductivity (EC) | Range: 0.000 μS/cm to 3000 mS/cm; Resolution: min 0.001 μS/cm (varies by range); Accuracy: ±0.5% FS; Reference temp: 5 / 10 / 15 / 18 / 20 / 25 °C; Calibration: up to 5 points; Reminder: Yes; Standards: 10 μS/cm, 84 μS/cm, 500 μS/cm, 1413 μS/cm, 12.88 mS/cm; 146.5 μS/cm, 1408 μS/cm, 12.85 mS/cm, 111.3 mS/cm; Temp. comp.: none / linear / pure water; Settable: cell constant, temp. coeff., TDS factor. |
| Resistivity | Range: 5.00 Ω·cm to 100.0 MΩ·cm; Resolution: min 0.01 Ω·cm; Accuracy: ±0.5% FS. |
| TDS | Range: 0.000 ppm to 1000 ppt; Resolution: min 0.001 ppm (varies by range); Accuracy: ±0.5% FS. |
| Salinity | Range: 0.0 to 80.0 ppt; Resolution: 0.1 ppt; Accuracy: ±1 ppt. |
Temperature & Measurement
| Parameter | Details |
|---|---|
| Temperature | Range: −10 to 135 °C (14 to 275 °F); Units: °C / °F; Resolution: 0.1; Accuracy: ±0.1 °C. |
| Measurement modes | Auto-Read (Fast / Medium / Slow), Timed, Continuous; Prompts: Reading / Stable / Locked. |
| Compensation | ATC / MTC. |
Data, I/O & System
| Parameter | Details |
|---|---|
| Data & GLP | Storage: 1000 groups; GLP features: Yes; Data analysis: review / compare / recalc. |
| Inputs | pH electrode: BNC (Q9); DO + Temp probe: 4-pin aviation; EC + Temp probe: 5-pin aviation. |
| Outputs | USB 2.0 (flash drive, PC, scanner). |
| Display | 4.3″ color high-contrast LCD touchscreen; Backlight: Yes; Auto shutdown: 300 / 600 / 1200 / 1800 / 3600 s or Off; Date & Time: Yes. |
| Protection | IP65. |
| Power | Rechargeable Li battery; AC adapter 100–240 V in, DC 5 V out. |
| Dimensions / Weight | 90 × 255 × 40 mm; 500 g (1.1 lb). |
Specifications subject to change without notice.
Why VIKING-M510A
- All-in-one portability: pH / ISE / EC / ORP / Temp.
- GLP traceability with up to 1000 data sets per parameter.
- Rugged IP65 design for field work.
- Fast workflows: auto-read, auto-hold, smart calibration & diagnostics.
Therefore, routine water tests finish faster and more reliably.








There are no reviews yet.