Two Shops
One Shipment

RITACUBA16R High-Speed Refrigerated Centrifuge


RITACUBA16R high-speed refrigerated centrifuge for PCR, molecular biology and routine sample preparation.

16,500 rpm / 24,148 × g · max. 6 × 50 ml · 8 fixed-angle rotors · 5-inch touch screen · 99 programs · rotor auto-ID.

COLO.Science — CENTRIFUGES / REFRIGERATED CENTRIFUGES — RITACUBA16R

RITACUBA16R high-speed refrigerated centrifuge for PCR, molecular biology and routine sample preparation

RITACUBA16R high-speed refrigerated centrifuge is a compact benchtop platform for laboratories that need high-speed refrigerated centrifugation, broad tube-format compatibility and reliable rotor configuration. It combines 16,500 rpm, 24,148 × g, automatic rotor identification, 99 stored programs, 10 acceleration / deceleration levels and an eight-rotor compatibility range for 1.5 / 2 ml microtubes, 5 ml and 10 ml round-bottom tubes, 15 ml conical tubes and 50 ml tube formats.

COLO.SCIENCE — COMPACT REFRIGERATED CENTRIFUGATION

Benchtop refrigerated centrifuge with high speed, cooling control and broad rotor compatibility

The RITACUBA16R is designed for molecular biology, PCR laboratories, molecular chemistry, bacterial separation and routine refrigerated sample preparation. The platform supports both small-volume microtube work and larger tube formats, allowing laboratories to configure the centrifuge according to tube geometry, sample volume, target RCF and required throughput.

Refrigerated operation supports temperature-sensitive samples, while the 5-inch touch screen, 99 user-defined programs, real-time parameter adjustment and automatic rotor identification help simplify repeated daily routines.

Key characteristics

  • RITACUBA16R high-speed refrigerated centrifuge with compact benchtop structure.
  • Maximum speed 16,500 rpm and maximum RCF 24,148 × g.
  • Maximum capacity 6 × 50 ml with rotor-dependent tube support.
  • Eight fixed-angle rotor options for microtubes, 5 ml, 10 ml, 15 ml and 50 ml formats.
  • Rapid pre-cooling from approx. 25 °C to 4 °C within about 6 minutes.
  • 99 user-defined programs for repeated centrifugation routines.
  • Automatic rotor identification for safer rotor setup.
  • 10 acceleration and 10 deceleration levels for sensitive sample handling.

Suitable for

  • PCR laboratories and molecular biology workflows.
  • Routine refrigerated sample preparation.
  • Molecular chemistry and small-batch laboratory separation.
  • Bacterial separation and laboratory centrifugation routines.
  • Microtube processing from 1.5 / 2 ml formats.
  • Conical and round-bottom tube formats up to 50 ml, depending on selected rotor.

SELECTION NOTE — RITACUBA16R CENTRIFUGE CONFIGURATION

RITACUBA16R high-speed refrigerated centrifuge for flexible laboratory tube formats

The RITACUBA16R high-speed refrigerated centrifuge is a strong choice when a laboratory needs one compact refrigerated centrifuge for multiple sample formats. The rotor range covers 12, 24, 36 and 48-place microtube configurations, as well as rotors for 5 ml, 10 ml, 15 ml and 50 ml tube formats.

When selecting the final configuration, the first step is the tube format: nominal tube volume, bottom geometry, cap type, sample volume and tube manufacturer limits. The second step is the target RCF and temperature requirement. Maximum centrifuge performance depends on the selected rotor, compatible adapters, correct balancing and the rated limits of the consumables used in the method.

For routine laboratory use, COLO can help match the rotor and adapter set to PCR tubes, microcentrifuge tubes, conical tubes, round-bottom tubes or 50 ml formats, with attention to cooling profile, speed, RCF, throughput and SOP requirements.

RITACUBA16R refrigerated centrifuge with flexible rotor configuration

RITACUBA16R high-speed refrigerated centrifuge 16,500 rpm with 8 rotor options

Compact centrifuge body, multiple rotor choices

RITACUBA16R supports eight fixed-angle rotor configurations for microtubes, 5 ml, 10 ml, 15 ml and 50 ml tube formats. The rotor list below keeps the page technically complete without overloading the visual layout.

Rotor selection should be confirmed according to tube format, sample volume, required RCF, cooling requirement and tube manufacturer limits.

TECHNICAL SPECIFICATIONS — RITACUBA16R HIGH-SPEED REFRIGERATED CENTRIFUGE

Product RITACUBA16R high-speed refrigerated centrifuge
Product number PRO6933
Structure Desktop / benchtop refrigerated centrifuge
Maximum speed 16,500 rpm
Maximum RCF 24,148 × g
Maximum capacity 6 × 50 ml
Standard rotor capacity 36 × 1.5 / 2 ml
Acceleration levels 10
Deceleration levels 10
Stored programs 99 user-defined programs
Instant centrifugation Supported
Display 5-inch touch screen
Speed accuracy 1 rpm
RCF accuracy 1 × g
Time accuracy 1 second
Refrigerant R134a
Cooling chamber Stainless steel bowl
Temperature stability Can remain stabilized at 4 °C at highest speed
Rapid pre-cooling Approx. 25 °C to 4 °C within 6 minutes
Rotor recognition Automatic rotor identification
Damping / balance 3-level rubber damping with automatic balance and imbalance switch function
Emergency lid release Supported in unexpected power failure
Noise 54 dB(A)
Body material High-strength steel
Rotor material NCP composite material
Dimensions (W × D × H) 620 × 330 × 270 mm
Single package 730 × 450 × 440 mm
Net weight 48 kg
Certification CE, ISO

Final centrifugation performance depends on selected rotor, tube format, tube manufacturer limits, correct balancing, selected program, temperature setpoint, sample load and laboratory SOP. Final configuration, adapters, accessories and documentation package should be confirmed in the official quotation.

Compatible fixed-angle rotors for RITACUBA16R

PRO3885 12 x 1.5 2 ml rotor for RITACUBA16R

Rotor SKU: PRO3885

12 × 1.5 / 2 ml

16,500 rpm · 21,610 × g · 45°
Order no. Hn011200020

PRO6935 24 x 1.5 2 ml rotor for RITACUBA16R

Rotor SKU: PRO6935

24 × 1.5 / 2 ml

15,000 rpm · 22,387 × g · 45°
Order no. HNN012400020

PRO6936 36 x 1.5 2 ml rotor for RITACUBA16R

Rotor SKU: PRO6936

36 × 1.5 / 2 ml

15,000 rpm · 22,262 × g · 45°
Order no. HNN013600020

PRO6937 48 x 1.5 2 ml rotor for RITACUBA16R

Rotor SKU: PRO6937

48 × 1.5 / 2 ml

12,000 rpm · 16,260 × g · 45°
Order no. HNN014800020

PRO6938 18 x 5 ml rotor for RITACUBA16R

Rotor SKU: PRO6938

18 × 5 ml

15,000 rpm · 24,148 × g · 45°
Order no. HNN011800050

PRO6939 12 x 10 ml rotor for RITACUBA16R

Rotor SKU: PRO6939

12 × 10 ml

13,000 rpm · 20,500 × g · 45°
Order no. HNN011200100

PRO6940 12 x 15 ml rotor for RITACUBA16R

Rotor SKU: PRO6940

12 × 15 ml

11,000 rpm · 15,620 × g · 30°
Order no. HNN011200150

PRO6934 6 x 50 ml rotor for RITACUBA16R

Rotor SKU: PRO6934

6 × 50 ml

11,000 rpm · 14,400 × g · 30°
Order no. HNN010600500

Rotor and adapter selection must be confirmed against tube format, tube manufacturer speed / RCF limits, sample volume, balancing requirements and laboratory SOP.

ADAPTERS, ROTOR SELECTION AND ORDERING SUPPORT

Compatible adapters for selected RITACUBA16R tube configurations

Adapters extend selected rotor configurations to additional tube formats. Before ordering, confirm the exact tube geometry, nominal volume, cap design, rated tube limits and required centrifugation method.

Adapter SKU Capacity Max speed Max RCF Order number
PRO6941 12 × 5 ml, round bottom 11,000 rpm 15,620 × g B011200150
PRO3189 6 × 15 ml, conical bottom 11,000 rpm 14,400 × g B6005006015
PRO6942 6 × 10 ml, round bottom 11,000 rpm 14,400 × g B6005006010

Ordering note: final quotation should confirm the centrifuge unit, rotor SKU, adapter SKU, tube format, operating speed, target RCF, temperature requirement, electrical configuration and documentation package.

Operating functions, cooling logic and safety support

Refrigerated operation

Rapid pre-cooling and stabilized low-temperature operation support temperature-sensitive samples during high-speed centrifugation.

Automatic rotor identification

Rotor auto-ID helps reduce the risk of selecting an incorrect rotor profile and supports safer configuration of repeated routines.

Soft start / stop control

10 acceleration and 10 deceleration levels help adapt the run profile to more sensitive sample types and reduce unwanted disturbance during braking.

Stored programs

99 user-defined programs support repeated centrifugation routines with consistent speed, RCF, time, temperature and acceleration / deceleration settings.

LABORATORY CENTRIFUGES CATALOGUE

Compare refrigerated centrifuges, microcentrifuges and rotor configurations

Use the laboratory centrifuges catalogue to compare centrifuge platforms, rotor capacities, tube formats, speed ranges, RCF values and application fit.

Open catalogue →

COLO.SCIENCE KNOWLEDGE AND SUPPORT

Rotor selection support for refrigerated centrifugation workflows

COLO.Science supports centrifuge selection by matching tube format, sample volume, required RCF, temperature profile, rotor capacity, balancing requirements and routine laboratory SOP.

COLO.Science →

Applications and operational value

Molecular biology

RITACUBA16R supports high-speed refrigerated processing of common tube formats used in nucleic acid, protein and small-volume laboratory workflows.

PCR laboratories

Stored methods, instant centrifugation and compact benchtop footprint support repeated daily routines in PCR and molecular testing laboratories.

Bacterial separation

Rotor-dependent tube support and refrigerated operation make the platform suitable for routine bacterial separation and sample preparation tasks.

Multi-format laboratory use

Eight compatible rotors allow one centrifuge platform to support microtubes, round-bottom tubes, conical tubes and larger 50 ml formats.

How to select the appropriate RITACUBA16R rotor configuration

Rotor selection should start with the tube, not only with maximum speed. Confirm the nominal tube volume, tube bottom geometry, cap design, maximum fill volume, rated tube speed / RCF and whether an adapter is required. After the tube format is confirmed, compare rotor capacity, maximum speed, maximum RCF and required throughput.

For temperature-sensitive samples, define the target temperature, pre-cooling requirement and acceptable run profile. For sensitive samples, 10 acceleration and 10 deceleration levels can help adapt the start / stop behavior. All rotor configurations must be loaded symmetrically and operated according to the laboratory SOP and the consumable manufacturer’s rated limits.

Compact refrigerated centrifuge platform with eight rotor options

The RITACUBA16R high-speed refrigerated centrifuge is practical for laboratories that need refrigerated high-speed centrifugation without moving to a large floor-standing platform. Its desktop structure, 5-inch touch screen, automatic rotor identification, NCP composite rotor platform and 99 stored programs support routine use in PCR, molecular biology, molecular chemistry and sample preparation environments.

The broad rotor range is the main configuration advantage. Laboratories can select microtube rotors for high-speed small-volume work, higher-throughput microtube rotors for repeated daily processing, and larger tube rotors for 5 ml, 10 ml, 15 ml or 50 ml formats. Final rotor choice should always be aligned with sample volume, required RCF, tube limits, cooling profile and balancing rules.

Configuration notice

RITACUBA16R may be supplied with different rotor, adapter and documentation configurations depending on the selected application. The official quotation defines the final delivery scope, including centrifuge unit, rotor SKU, adapter SKU, electrical configuration, accessories and documentation requirements. Website content is intended for general product presentation and may not represent the exact delivered configuration. Specifications may change without notice.

Need help choosing a RITACUBA16R rotor configuration?

Contact COLO.Science to confirm the centrifuge unit, rotor selection, adapter configuration, tube format, sample volume range, target RCF, cooling profile, balancing requirements and documentation package.

SKU: PRO6933 Category:

Request a Quote