PROGRAMMABLE LARGE-AREA LABORATORY HEATING
Separate control electronics from the immediate heating and reagent zone
The split architecture connects the heating unit and controller through dedicated aviation-style power and signal connections. Where the laboratory layout permits, the controller can be positioned away from the hottest part of the work zone, improving access to the interface and reducing direct exposure of the electronics to hot vessels and routine reagent handling.
The smooth 6 mm glass-ceramic surface provides a large, flat working area for compatible vessels. The GOBI-GC laboratory hotplate should be selected according to vessel footprint, total load, target temperature, electrical supply and the validated laboratory method.
CORE PRODUCT ADVANTAGES
Controlled heating for repeatable laboratory workflows
Smooth 6 mm working surface
The flat, non-porous surface supports stable vessel positioning, responsive heating and straightforward wipe-down after the plate has been made safe and allowed to cool.
Programmable temperature control
The touch-screen controller provides 0.1 °C setting increments, multi-point compensation, real-time curves and programmable time-temperature procedures.
Separate heater and controller
Dedicated connections allow the control unit to be arranged separately from the heating plate while keeping the complete system electrically and functionally integrated.
Process and protection functions
Two temperature probes support process supervision and the adjustable independent over-temperature protection circuit.
GOBI-GC glass-ceramic heating and control architecture

High-temperature glass-ceramic surface
The GC25 and GC35 models operate from RT+20 °C to 500 °C, while the larger GC45 model operates from RT+20 °C to 460 °C.

LCD touch interface and live curves
Operators can view the set point, process time and heating curve while selecting or editing stored multi-stage methods.

Dedicated controller connections
Power and signal connections link the remote controller to the heater. Cables and connectors must remain protected from hot vessels, spills and corrosive vapours.

Sealed and service-conscious construction
The system combines a sealed 304 stainless-steel body, nano-resin external coating, titanium-plated insulation structure and adjustable levelling feet.
INTELLIGENT TEMPERATURE CONTROL
Build repeatable heating methods instead of relying on manual set-point changes
Ten named methods
Store up to ten commonly used procedures and assign custom names so routine operators can identify validated programs more easily.
Six-stage programming
Define up to six temperature and time segments for preheating, ramping, holding, reaction, reduction and end-of-method logic.
Multi-point compensation
Compensation at multiple temperature points helps refine the controller response across the intended working range.
Over-temperature protection
An adjustable independent protection function provides an additional safety layer beside normal PID process control.
The GOBI-GC laboratory hotplate provides a controller resolution and temperature increment of 0.1 °C. This resolution describes the setting and display capability; it does not replace method validation or direct confirmation of the actual sample temperature where the process requires it.
MODEL SELECTION
Choose the working area, temperature range and electrical load
All GOBI-GC models use an LCD touch controller, a 6 mm glass-ceramic plate, a maximum plate load of 5 kg and a timing range of 0–9999 minutes. Model selection should begin with the vessel arrangement and available electrical installation rather than plate size alone.
COMMON TECHNICAL SPECIFICATIONS — GOBI-GC SERIES
| Product type | Programmable glass-ceramic laboratory heating plate |
| Available models | GOBI-GC25, GOBI-GC35, GOBI-GC45 |
| Power supply | AC 220 V, 50 Hz |
| Display and controller | Separate LCD touch-screen PID controller |
| Temperature accuracy | ±7%, as stated in the current catalogue |
| Controller resolution | 0.1 °C |
| Temperature increment | 0.1 °C |
| Timing range | 0–9999 min |
| Method memory | Up to 10 custom-named methods |
| Program structure | Up to 6 temperature/time stages |
| Plate material / thickness | Glass-ceramic / 6 mm |
| Maximum plate load | 5 kg |
| Main body | Sealed 304 stainless steel with nano-resin external coating |
| Safety and monitoring | Dual temperature-probe monitoring and adjustable over-temperature protection |
RT = room temperature. Electrical installation, wiring, plug, circuit protection and bench suitability must be confirmed for the selected model and applicable local regulations. The GC25 circuit-breaker rating is not specified in the current catalogue and must be confirmed before installation.
Applications for the GOBI-GC laboratory hotplate
Sample preparation
Controlled preheating, dissolution and conditioning of compatible samples and reagents before instrumental analysis.
Digestion procedures
Heating of compatible digestion vessels for validated acid or reagent-based procedures with appropriate local exhaust.
Chemical synthesis
Repeatable thermal segments for laboratory reactions that require controlled ramp, hold and reaction periods.
Evaporation and concentration
Controlled reduction of water or compatible solvents using suitable vessels, supervision and ventilation.
METHOD DEVELOPMENT
Define the vessel and method before setting the temperature
- Match vessel material, dimensions and bottom geometry to the reagent and target temperature.
- Account for sample mass, vessel count, distribution and thermal lag when defining hold times.
- Use validated sample-temperature monitoring where the method requires confirmation inside the vessel.
- Record method names, program stages, acceptance criteria and shutdown requirements.
SAFE LABORATORY INTEGRATION
Plan ventilation, clearances and electrical protection
- Use suitable local exhaust or a fume hood for hazardous or corrosive vapours.
- Do not exceed the 5 kg plate load or the vessel manufacturer’s temperature and loading limits.
- Keep flammable materials, cables and control electronics away from the hot surface.
- Follow the SDS, laboratory risk assessment and method-appropriate PPE requirements.
CONFIGURATION GUIDE
How to select the correct GOBI-GC model
Begin with the real vessel layout. Confirm the number of vessels, their outside dimensions, total loaded mass, required spacing and whether the bases make stable contact with the glass-ceramic surface. The plate must be large enough for stable positioning without exceeding the 5 kg maximum load.
Then confirm the highest validated operating temperature and the required heating power. GOBI-GC25 and GOBI-GC35 reach 500 °C, while GOBI-GC45 provides the largest area with a maximum control temperature of 460 °C. Larger power ratings require appropriate electrical installation and circuit protection.
The GOBI-GC laboratory hotplate is a heating platform, not a complete digestion or evaporation safety system. Vessel compatibility, ventilation, spill control, operator protection and actual method performance remain part of the laboratory’s validated procedure.
LABORATORY HOTPLATE CATEGORY
Compare laboratory heating plate technologies
Review glass-ceramic, aluminium, graphite and other laboratory hotplate configurations by surface material, working area, control type and operating temperature.
COLO.SCIENCE KNOWLEDGE AND SUPPORT
Technical guidance for laboratory heating
COLO.Science supports model selection according to vessel layout, reagent system, target temperature, process stages, electrical supply and laboratory safety requirements.
Configuration and specification notice
The heating plate, controller, cables, connectors, vessels, electrical installation and ventilation provisions form one operating system. The official quotation and order confirmation must define the selected model, supply voltage, plug, circuit protection, included components and final operating limits. Website content supports preliminary selection and does not replace the binding quotation, operating manual, laboratory risk assessment or method validation. Specifications may change without notice.