Conductivity Electrode (k=0.01, ATC) 0.05~20 μS/cm/ Φ12×120 mm, 5-pin aviation, Titanium alloy


  • k=0.01 cm⁻¹
  • Titanium alloy
  • 0.05–20 µS/cm

195,00

Conductivity Electrode (k=0.01, ATC) – Pure Water Conductivity Sensor

  • Conductivity
  • TDS / Resistivity / Salinity
  • k=0.01 cm⁻¹
  • ATC (automatic temp. comp.)
  • Titanium alloy
  • 5‑pin aviation
  • 0.05–20 µS/cm


High-precision conductivity electrode with k=0.01 cm⁻¹, integrated ATC

OVERVIEW

The conductivity electrode with cell constant k=0.01 cm⁻¹ is specifically designed for pure water and low‑conductivity measurements (0.05…20 µS/cm). It features integrated automatic temperature compensation (ATC) and a robust titanium alloy sensor body. Depending on the meter, it can measure conductivity, TDS, resistivity, and salinity. Four different cell constants are available to match your application; this model uses a 5‑pin aviation connector for secure and interference‑free signal transmission.

Manufactured by INESA, this electrode guarantees high accuracy and long‑term stability for laboratory and industrial pure water monitoring, pharmaceutical water systems, and power plant water treatment.

High‑precision conductivity electrode for ultra‑pure water with k=0.01 cm⁻¹, titanium alloy construction, and built‑in ATC. Compatible with meters featuring a 5‑pin aviation connector.COLO.Science · Trusted sensors for critical water analysis.


COLO.SCIENCE KNOWLEDGE

Practical insights for conductivity measurement

Explore COLO.Science articles on conductivity theory, cell constant selection, pure water analysis, and electrode maintenance.


Read on COLO.Science →


Product Overview

This conductivity electrode (k=0.01, ATC) is optimised for pure water applications (0.05–20 µS/cm). The titanium alloy sensing elements provide excellent corrosion resistance and measurement stability. The integrated Pt1000 temperature sensor enables automatic temperature compensation (ATC) when used with compatible meters. The 5‑pin aviation connector ensures a reliable, shielded connection.

Configuration notice — delivery depends on selected options

Electrodes may be delivered with different connectors or cable lengths. The official PDF specification defines the exact configuration. Content shown is for general informational purposes only. Specifications may change without notice.

Key Features

k=0.01 cm⁻¹
0.05–20 µS/cm range
Titanium alloy sensor
ATC (Pt1000)
Measures TDS / resistivity / salinity
Four cell constants available
5‑pin aviation connector
Working temp. 0–60 °C
Φ18×50 mm

Electrode
Designed for pure water & low conductivity

Multi‑parameter measurement

Depending on the meter, the electrode delivers conductivity, TDS, resistivity, and salinity values.

Four cell constants

Available constants: 0.01, 0.1, 1.0, 10.0 cm⁻¹ – select the optimal one for your conductivity range.

Robust titanium alloy

The sensor body and electrodes are made of titanium alloy, offering excellent chemical resistance and long life.

Measurement Capabilities

  • Conductivity range: 0.05 … 20 µS/cm (for k=0.01)
  • Supports TDS, resistivity, salinity calculation
  • Integrated Pt1000 ATC (0…60 °C)
  • Cell constant k=0.01 cm⁻¹ (other constants available)

Construction

  • Sensor material: Titanium alloy
  • Shaft dimensions: Φ18 × 50 mm
  • Working temperature: 0 … 60 °C
  • Pressure tolerance: up to 0.5 MPa

Connectivity

  • 5‑pin aviation connector (shielded)
  • Cable length: 1 m (standard, other lengths optional)
  • Compatible with many laboratory and industrial meters
  • BNC, DIN, or other connectors available on request

Technical Specifications (k=0.01, ATC)

Parameter Specification Parameter Specification
Model DJS‑0.01‑ATC (INESA) Name Conductivity Electrode (k=0.01, ATC)
Measurement Range 0.05 – 20 µS/cm Cell constant k=0.01 cm⁻¹ (±1%)
Sensor material Titanium alloy Working Temp. 0 – 60 °C
Temperature sensor Pt1000 (ATC) Dimension Φ18 × 50 mm (sensor)
Connector 5‑pin aviation (standard) Cable length 1 m (custom lengths available)
Pressure max 0.5 MPa Material (body) Stainless steel / titanium alloy

Note: For detailed specifications of other cell constants (k=0.1, 1.0, 10.0) please refer to the electrode catalog (PDF).

Standard Delivery

  • Conductivity electrode (k=0.01, ATC) with 5‑pin aviation connector
  • Instruction manual
  • Quality certificate / test report
  • Optional: longer cable, BNC/DIN adapter, calibration solutions

Exact kit contents may vary by region; please refer to the current catalog and quotation for final configuration.

Available Cell Constants & Ranges

Choose the right cell constant for your conductivity range.

Cell constant (cm⁻¹) Typical measurement range Application
k=0.01 0.05 – 20 µS/cm Ultra‑pure water, boiler condensate
k=0.1 0.5 – 200 µS/cm Deionized water, drinking water
k=1.0 10 – 2000 µS/cm Surface water, wastewater, general purpose
k=10.0 1 – 200 mS/cm High conductivity brines, industrial effluents