Two Shops
One Shipment

KJELFASTER-K500 Automatic Kjeldahl Analyzer

Availability:

Available on backorder


COLO.Science · Automatic Kjeldahl Analyzer

0.1–240 mg N · Recovery ≥99.5 % · ≤ ±0.5 % · 2.0 µL/step · 5–10 min per sample


COLO.Science — Organic elemental analysis · Kjeldahl

KJELFASTER-K500 Automatic Kjeldahl Analyzer

KJELFASTER-K500 is an automatic Kjeldahl analyzer that combines steam distillation, colorimetric titration, calculation and printout in one instrument. It measures 0.1–240 mg N with recovery ≥99.5 % and a reproducibility (relative error of mean value) of ≤ ±0.5 %, titrates with 2.0 µL/step resolution, needs 5–10 min per sample and stores 1000 results. Four dosing pumps, pre-installed cleaning routines and an integrated printer make it a complete analyzer at an accessible price.

Automatic Kjeldahl analyzerDistillation + titration0.1–240 mg NRecovery ≥99.5 %Reproducibility ≤ ±0.5 %Burette 2.0 µL/step1000 resultsIntegrated printer

Overview

Applications

  • Food and feed: crude protein in food, dairy, meat, cereals and feed.
  • Quality control: routine incoming and release testing with printed results.
  • Water and environment: total Kjeldahl nitrogen (TKN) and ammonium nitrogen.
  • Agriculture: nitrogen in soil, plants and fertilizers after digestion.

Why KJELFASTER-K500

  • Complete analyzer: distillation, titration, calculation and printout — no separate titrator or PC needed.
  • Low running cost: standard φ42 mm × 300 mL tubes, open reagents and catalysts, no paid software options.
  • Clean and safe: pre-installed cleaning of cup and lines; distillate temperature monitoring stops the unit if abnormal.
  • Support: installation, operator training and method validation on your sample by COLO.Science.

Technical specifications

Model KJELFASTER-K500
SKU PRO3573
Instrument type Automatic Kjeldahl analyzer (distillation + titration)
Measuring range 0.1–240 mg N
Recovery ≥99.5 %
Reproducibility relative error of mean value ≤ ±0.5 %
Time per sample 5–10 min per sample
Sample size solid ≤5 g, liquid ≤20 mL
Digestion tubes φ42 mm, 300 mL (standard, open format)
Titration colorimetric endpoint, external titration cup
Burette resolution 2.0 µL/step
Dosing 4 dosing pumps
Cleaning receiving cup, alkali and boric acid lines, acid washing, steam generator drain
Safety functions distillate temperature monitoring with automatic stop
Data memory 1000 results
Printer integrated
Cooling water consumption 1.5 L/min
Power supply 220 V AC ±10 %, 50 Hz
Rated power 2 kW
Dimensions (W×D×H) 455 × 391 × 730 mm
Weight 38 kg

OPTIONS AND ACCESSORIES

Options and accessories for the KJELFASTER-K500

Standard delivery is confirmed in the quotation (integrated printer included). Digestion tubes, catalyst tablets and reagents are ordered separately; KJELDIG digestors and the EXSC5 scrubber complete the system.

KJELDIG-D250 Kjeldahl digestor PRO3575

PRO3575

KJELDIG-D250 Kjeldahl digestor

20 × 300 mL, up to 450 °C, ±1 °C, 10 programs × 5 steps; fume hood included.

Optional

KJELDIG-D450 infrared Kjeldahl digestor PRO3576

PRO3576

KJELDIG-D450 infrared Kjeldahl digestor

Infrared + graphite, 400 °C in 25 min, 20 programs; hood and cooling rack included.

Optional

EXSC5 scrubber PRO5814

PRO5814

EXSC5 scrubber

Three-stage neutralization: water condensation, alkali, activated carbon; adjustable suction.

Optional

Digestion tubes φ42 × 300 mL (set) —

—

Digestion tubes φ42 × 300 mL (set)

Standard open-format tubes for all KJELDIG digestors and KJELFAST / KJELFASTER units — one tube from digestion to distillation.

Optional

More options and consumables

  • Built-in printer
  • Reagent tanks (spare)
  • Kjeldahl catalyst tablets
  • Reagents: sulfuric acid, NaOH 40 %, boric acid with indicator, standard acid

Digestion tubes, reagents and spare parts on request. Full catalogue: Organic elemental analysis catalogue →

Selection guidance

KJELFASTER-K500 is selected when a routine laboratory wants distillation, titration and printout in one instrument at an accessible price. For finer burette resolution and process protection choose K700; for data integrity, 1 million results and an autosampler the K900.

Configuration checklist

  • Daily samples: routine series; for unattended batches see K900 with A24.
  • Resolution: 2.0 µL/step; for low-nitrogen samples choose K700 (1.0) or K900 (0.2 µL/step).
  • Digestion: KJELDIG digestor and EXSC5 scrubber.
  • Utilities: cooling water tap, drain and 220 V socket next to the bench.

Sales and support for international customers

COLO Lab ExpertsPolje ob Sotli 4, SI-3255 Buče, Slovenia
Phone: +386 70 713 437 · Email: sales@colo.si · Web: colo.si
We supply laboratories across Europe directly and through partners. B2B prices are quoted net, excluding VAT.

Need help configuring your Kjeldahl system?

Tell us the sample types and daily number of samples. COLO.Science will configure the system with the KJELFASTER-K500 (digestor, scrubber, analyzer), validate the method on your sample and send a quotation.

SKU: PRO3573 Category:
  • Automatic accurate distribute alkali and boric acid solution.
  • Perfect safety protection system gives distiller and tubes measurement and protection against over temperature and over pressure.
  • Calibration Function: Dilution water calibration, Alkali solution calibration, Boric acid solution calibration, Washing flow calibration.
  • Safety door, digestion tube and cooling water conditions are displayed in real time when running.

Request a Quote