COLO.Science — WEIGHING / HYDROSTATIC ANALYTICAL BALANCES
HYBANB320 hydrostatic analytical balance 320 g / 0.1 mg with internal calibration and touch screen LCD
HYBANB320 hydrostatic analytical balance is a high-resolution laboratory balance configuration for density determination, hydrostatic weighing and analytical weighing workflows. The controlled commercial configuration uses catalogue SKU PRO2304, 320 g capacity, 0.1 mg readability, internal calibration, touch screen LCD operation and RS232 data output for compatible printers, computers and documentation workflows.
COLO.SCIENCE — HYDROSTATIC DENSITY DETERMINATION
0.1 mg readability for density weighing, analytical weighing and documented laboratory work
HYBANB320 hydrostatic analytical balance is designed for laboratories that need density determination of samples and materials together with high-resolution analytical weighing. The hydrostatic weighing configuration supports density workflows where sample, liquid, temperature and weighing stability must be controlled according to the laboratory method.
The balance platform includes internal calibration, touch screen LCD with backlight, high-precision electromagnetic balance sensor, automatic fault detection, overload protection, unit conversion, percentage function, parts counting and built-in RS232 interface for compatible printers, computers and data processing workflows.
Key characteristics
- Controlled model: HYBANB320.
- Catalogue SKU: PRO2304.
- Maximum capacity: 320 g.
- Readability: 0.1 mg.
- Calibration: internal calibration.
- Sensor: high-precision electromagnetic balance sensor.
- Display: LCD with backlight, touch screen operation.
- Interface: built-in RS232 for compatible printer or PC workflow.
- Application: hydrostatic density determination and analytical weighing.
Suitable for
- Hydrostatic density determination of laboratory samples and materials.
- Density weighing with temperature compensation where required.
- Analytical weighing workflows requiring 0.1 mg readability.
- Quality control, research and material verification tasks.
- Parts counting and percentage weighing functions.
- Documented weighing using optional printer or compatible PC data collection.
HYBANB320 — HYDROSTATIC ANALYTICAL BALANCE FOR DENSITY DETERMINATION
HYBANB320 hydrostatic analytical balance for laboratory density weighing
HYBANB320 hydrostatic analytical balance is suitable when a laboratory needs one instrument for hydrostatic density determination and high-resolution analytical weighing. With 320 g capacity and 0.1 mg readability, the balance can be used for sample density workflows, material checks, routine weighing, parts counting and percentage weighing in controlled laboratory conditions.
Internal calibration supports daily operation and simplifies routine balance preparation before measurement. The touch screen LCD gives clear access to weighing functions, while the RS232 interface supports compatible printer and PC workflows where weighing results must be recorded or processed outside the balance.
For best results, HYBANB320 hydrostatic analytical balance should be installed on a stable weighing bench, protected from vibration and air movement, levelled correctly and used with an appropriate control-weight routine. Optional OIML E2 weights and printer configuration can be selected according to laboratory SOP and documentation requirements.
HYBANB balance, E2 weights and optional printer

HYBANB320 hydrostatic analytical balance combines 320 g capacity, 0.1 mg readability, internal calibration, touch screen LCD and hydrostatic density weighing configuration.

Optional OIML E2 weights are used for independent routine checks, control points, audit support and documented balance verification procedures.

Optional thermal printer supports paper records of weighing and density results when laboratory procedures require direct printout.
HYBANB320 — catalogue selection parameters
| Catalogue SKU | Model | Capacity | Readability | Calibration | Application | Interface | Options |
|---|---|---|---|---|---|---|---|
| PRO2304 | HYBANB320 | 320 g | 0.1 mg | Internal | Hydrostatic density | RS232 | E2 weights, printer |
Source note: the legacy HYBANB source contains older capacity/model references, including 300 g / 1 mg text. This page uses the controlled master data PRO2304 / HYBANB320 / 320 g / 0.1 mg. Final technical label, delivered kit content and accessory package should be confirmed in the official quotation.
TECHNICAL SPECIFICATIONS — HYBANB320 HYDROSTATIC ANALYTICAL BALANCE
| Product model | HYBANB320 hydrostatic analytical balance |
| Catalogue SKU | PRO2304 |
| Balance type | Hydrostatic analytical balance for density determination and high-resolution laboratory weighing |
| Maximum capacity | 320 g |
| Readability | 0.1 mg |
| Calibration | Internal calibration |
| Sensor | High-precision electromagnetic balance sensor |
| Display | LCD with backlight, touch screen operation |
| Interface / output | Built-in RS232 |
| Pan size | Diameter 90 mm |
| Power supply | Universal adapter AC 110–240 V |
| Main functions | Density display, temperature compensation, weighing, parts counting, unit conversion, percentage function |
| Protection / diagnostics | Automatic fault detection and overload protection |
| Standard configuration | HYBANB320 main unit, hydrostatic density configuration, internal calibration, AC 110–240 V adapter, user manual / quick guide |
| Optional accessories | OIML E2 calibration / control weights, printer, RS232 / PC data workflow accessories, certificates according to laboratory SOP |
Final weighing and density performance depends on correct installation, vibration control, stable temperature, suitable liquid/sample preparation, correct levelling, internal calibration routine, control-weight practice and documentation requirements. Final configuration, certificates and accessories are confirmed in the official quotation.
Operating and density-weighing functions
Hydrostatic density determination
The hydrostatic configuration supports density determination of samples and materials where sample preparation, liquid selection and temperature conditions are controlled by the laboratory method.
Analytical weighing
0.1 mg readability supports high-resolution laboratory weighing for mass checks, sample preparation, QC work and routine analytical workflows.
Temperature compensation
Temperature compensation can be used in density workflows where liquid temperature has to be considered as part of the measurement procedure.
RS232 data output
Built-in RS232 output supports compatible printer, PC data collection and documentation workflows for laboratories that need measurement records.
STANDARD CONFIGURATION, OPTIONAL ACCESSORIES AND E2 CONTROL WEIGHTS
Hydrostatic kit, internal calibration, optional OIML E2 weights and optional printer
HYBANB320 is supplied as a hydrostatic analytical balance configuration for density weighing. Optional OIML E2 control weights, printer and compatible RS232 / PC workflow accessories can be selected according to the laboratory SOP, certificate requirements and documentation method.

OIML E2 calibration / control weights
Recommended for independent routine checks, control points around working mass values, audit support and documented balance verification procedures.

Optional thermal printer
Supports printed measurement records when density or weighing results must be documented directly after measurement.
Configuration logic
- Confirm density method and sample type before quotation.
- Confirm liquid, temperature and hydrostatic accessory requirements.
- Define required E2 weight values and certificates.
- Confirm printer, RS232 cable and PC software requirements.
- Confirm final kit content and delivered configuration.
Ordering note: final HYBANB320 configuration should confirm capacity/readability label, hydrostatic kit content, internal calibration, E2 control weights, certificates, printer, RS232 / PC workflow and documentation package.
WEIGHING CATALOGUE
Compare hydrostatic balances, analytical balances and calibration weights
Use the weighing catalogue to compare HYBANB320 with other analytical balances, hydrostatic density balances, precision balances, calibration weights and weighing accessories.
COLO.SCIENCE KNOWLEDGE AND SUPPORT
Selection support for density method, E2 weights and documentation workflow
COLO.Science supports complete weighing configurations: hydrostatic density method review, balance selection, E2 weight selection, printer workflow, RS232 / PC data collection and documentation requirements for laboratory users.
How to confirm the appropriate HYBANB320 configuration
Before quotation, confirm the sample type, expected density method, required capacity and readability, suitable liquid, temperature conditions and hydrostatic accessory requirements. This prevents configuration mismatch and helps define the correct laboratory operating procedure.
For documented laboratory work, also confirm the calibration and checking routine, required OIML E2 weight values, certificate expectations, printer requirement, RS232 / PC export requirement and final kit content. The official quotation defines the final delivered configuration.
HYBANB320 hydrostatic analytical balance for density determination and 0.1 mg laboratory weighing
HYBANB320 hydrostatic analytical balance is intended for laboratories that need density determination and high-resolution weighing in one controlled configuration. The balance combines 320 g capacity, 0.1 mg readability, internal calibration, touch screen LCD with backlight, electromagnetic balance sensor, density display, temperature compensation, weighing, parts counting, unit conversion and percentage functions.
In practical use, density and mass results depend on the selected method, liquid, sample geometry, temperature stability, correct installation, levelling, vibration control, calibration routine and control-weight practice. Optional OIML E2 weights, printer, RS232 accessories and PC data workflow can be added according to laboratory SOP and documentation requirements.
Configuration notice
HYBANB320 hydrostatic analytical balance may be supplied with different accessory and documentation configurations depending on density method, sample type, E2 weight requirements, printer requirement, RS232 / PC data workflow, certificates and final quotation. The legacy HYBANB source includes older capacity/model references, including 300 g / 1 mg text. This web page uses controlled master data PRO2304 / HYBANB320 / 320 g / 0.1 mg and the final delivered configuration should always be confirmed before ordering. Specifications may change without notice.