Two Shops
One Shipment
,

FAMO100 Laboratory Moisture Analyzer | COLO.Science


FAMO100 laboratory moisture analyzer; 110 g capacity; 1 mg weighing readability; 0.01% moisture readability; 0.5 g minimum / 2–50 g advised sample; quartz IR heating 50–180°C; external calibration; Ø90 mm pan; touch-screen LCD; RS232C standard / USB optional.

COLO.SCIENCE — TESTING EQUIPMENT / MOISTURE ANALYZERS — FAMO100

FAMO100 laboratory moisture analyzer with 110 g capacity, 1 mg readability and quartz IR heating

FAMO100 is a compact laboratory moisture analyzer for routine moisture determination and dry weighing workflows. It combines 110 g capacity, 1 mg weighing readability, 0.01% moisture readability, quartz infrared heating from 50°C to 180°C, a backlit LCD touch screen, external calibration and RS232C communication for practical day-to-day laboratory analysis.

COLO.SCIENCE — ROUTINE MOISTURE AND DRY-CONTENT ANALYSIS

Compact weighing, controlled drying and direct touch-screen operation

The FAMO100 laboratory moisture analyzer determines moisture by recording the initial sample mass and the mass loss generated during controlled quartz IR heating. The instrument supports both moisture determination and dry weighing determination, allowing routine laboratories to evaluate moisture percentage and solid content within a compact bench-top workflow.

A 110 g weighing range, 1 mg division, 0.01% moisture readability and an advised sample mass of 2–50 g make FAMO100 suitable for practical quality-control methods where operator simplicity, adjustable drying conditions and rapid stabilization are important.

Key characteristics

  • Model: FAMO100.
  • Maximum capacity: 110 g.
  • Weighing readability: 0.001 g / 1 mg.
  • Moisture readability: 0.01%.
  • Minimum sample weight: 0.5 g.
  • Advised sample weight: 2–50 g.
  • Temperature range: 50°C to 180°C.
  • Heating source: quartz IR lamp.
  • Calibration: external.
  • Sample pan: Ø90 mm.

Suitable for

  • Food ingredients, raw materials and finished products.
  • Grains, feed and agricultural samples.
  • Pharmaceutical and chemical quality-control work.
  • Powders, polymers, paper and textile samples.
  • Incoming material control and process verification.
  • Method development with sample-specific drying temperature and time.
  • Routine laboratories requiring a compact touch-screen analyzer.

FAMO100 — LABORATORY MOISTURE ANALYZER

FAMO100 laboratory moisture analyzer for routine quality-control testing

A laboratory moisture analyzer should be selected according to sample type, representative sample mass, required result resolution, drying temperature, method duration and reporting requirements. FAMO100 provides a practical 110 g platform with 1 mg weighing readability and 0.01% moisture readability for routine laboratory work.

Quartz infrared heating can be adjusted from 50°C to 180°C in 1°C steps. The heating time can be set from 0 to 99 minutes in one-minute intervals, supporting sample-specific moisture methods for food, agricultural, pharmaceutical, chemical and industrial materials.

For documented laboratory workflows, the FAMO100 laboratory moisture analyzer can be combined with an optional thermal printer, optional USB connection and suitable OIML F1 weights for external calibration and routine control. Final accessory compatibility and documentation scope should be confirmed in the official quotation.

FAMO100 moisture analyzer, optional printer and F1 weights

FAMO100 laboratory moisture analyzer for quartz IR moisture determination

FAMO100 combines 110 g capacity, 1 mg division, 0.01% moisture readability, quartz IR heating and a backlit LCD touch screen.

Optional OIML F1 weights for external calibration of FAMO100 laboratory moisture analyzer

Optional OIML F1 weights support external calibration, routine checks, SOP control points and documented verification of the integrated weighing system.

Optional thermal printer for FAMO100 moisture analyzer measurement records

An optional compatible thermal printer can support direct printout of moisture and weighing results when paper records are required.

FAMO100 model and catalogue selection parameters

FAMO100

Capacity: 110 g
Division: 0.001 g / 1 mg
Moisture readability: 0.01%
Minimum sample: 0.5 g
Advised sample: 2–50 g
Calibration: External
Sample pan: Ø90 mm
Temperature: 50°C–180°C

Model note: confirm the required calibration-weight nominal value, printer compatibility, optional USB connection, software scope, certificates and final documentation package in the official quotation.

TECHNICAL SPECIFICATIONS — FAMO100 LABORATORY MOISTURE ANALYZER

Product model FAMO100
Instrument type Laboratory moisture analyzer, touch-screen model
Measurement modes Moisture determination / dry weighing determination
Accuracy class Class II
Maximum capacity 110 g
Weighing readability 0.001 g / 1 mg
Moisture readability 0.01%
Minimum sample weight 0.5 g
Advised sample weight 2–50 g
Moisture range 0–100%
Dry weighing range 100.00%–0%
Calibration External
Heating source Quartz IR heating lamp
Temperature sensor Pt100
Temperature range 50°C–180°C
Temperature setting step 1°C
Heating time 0–99 min, 1 min interval
Display Backlit LCD touch screen
Displayed content Moisture %, solid %, weight, time and measurement data
Communication RS232C standard; USB optional
Sample pan Ø90 mm
Operating temperature 15°C–30°C; fluctuation <5°C/h
Operating relative humidity 40%–80% RH
Power supply AC 110–240 V, 50/60 Hz; DC 5 V–2 A
Dimensions 325 × 195 × 195 mm
Net / gross weight 2.3 / 3 kg

Final measurement performance depends on suitable sample preparation, representative sample mass, correct drying temperature and time, stable installation, levelling, external calibration, ambient conditions and the validated laboratory method. Final accessories, interfaces and documentation are confirmed in the official quotation.

STANDARD PACKAGING / STANDARD DELIVERY

Standard FAMO100 package

Included in standard packaging

  • FAMO100 laboratory moisture analyzer.
  • Service-certified calibration weight.
  • Universal power adapter.
  • Dust cover.
  • Instruction manual / user documentation.

Optional configuration

  • Compatible thermal printer.
  • OIML F1 calibration and control weights.
  • USB connection.
  • Certificates and additional documentation.
  • Additional sample pans and consumables, where available.

Moisture measurement workflow

1. Weigh

Place the prepared sample on the Ø90 mm pan and record the initial sample mass.

2. Heat

Apply the selected quartz IR drying temperature and programmed heating time.

3. Monitor

Follow mass loss and displayed moisture, solid, weight and time information.

4. Result

Record the final moisture or dry-content result according to the laboratory method.

OPTIONAL ACCESSORIES AND CALIBRATION SUPPORT

Optional F1 weights, printer and USB connection

FAMO100 uses external calibration. Suitable OIML F1 weights may therefore be selected for calibration and routine verification. Printer and USB options should be matched to the required laboratory reporting and communication workflow.

OIML F1 calibration weight set for FAMO100 laboratory moisture analyzer

OIML F1 calibration weights

Suitable for external calibration, independent routine checks, SOP control points and documented verification of the weighing platform.

Optional thermal printer for FAMO100 laboratory moisture analyzer

Optional thermal printer

Supports direct paper records when laboratory procedures require printout of moisture or weighing results.

Optional communication workflow

  • RS232C standard interface.
  • USB connection optional.
  • Printer compatibility should be confirmed.
  • Final data workflow and documentation should be specified before ordering.

Ordering note: confirm the calibration-weight nominal value, printer compatibility, optional USB connection, certificate requirements and final documentation package in the official quotation.

MOISTURE ANALYZERS

Compare laboratory moisture analyzers and moisture meters

Use the moisture analyzer category to compare FAMO100 with other instruments for laboratory moisture determination, grain moisture measurement and dry-content analysis.

Open category →

COLO.SCIENCE KNOWLEDGE AND SUPPORT

Selection support for moisture methods, sample mass and calibration

COLO.Science supports moisture-analyzer selection, sample-mass planning, drying-temperature definition, external calibration, F1 weight selection, printer workflow and documentation requirements.

COLO.Science →

How to select and configure FAMO100

Before ordering a laboratory moisture analyzer, define the sample material, expected moisture level, representative sample mass and suitable drying temperature. FAMO100 is recommended for sample masses from 2 g to 50 g, while the minimum permitted sample weight is 0.5 g.

The second step is method and documentation planning. Confirm the required heating time, whether standard RS232C is sufficient, whether optional USB or a printer is needed, and which F1 calibration-weight nominal value and certificate should be supplied.

FAMO100 laboratory moisture analyzer for compact bench-top testing

The FAMO100 laboratory moisture analyzer is designed for users who need a compact and practical instrument for daily moisture and dry-content measurements. Its quartz IR heating source, Pt100 temperature sensor, backlit touch screen and adjustable drying conditions support controlled testing across a broad range of laboratory samples.

Reliable operation depends on representative sampling, uniform sample distribution, correct drying temperature and time, stable installation, proper levelling and regular external calibration. Optional F1 weights, printer and USB connection can be selected according to the laboratory procedure and reporting requirement.

Configuration notice

FAMO100 may be supplied with different accessories and documentation depending on the application. The official quotation defines the calibration-weight value, printer compatibility, optional USB connection, certificates and final delivery scope. Specifications may change without notice.

Need help configuring a FAMO100 laboratory moisture analyzer?

Contact COLO.Science to confirm sample type, sample mass, drying temperature, heating time, external calibration, F1 weights, printer, USB connection, certificates and final delivered configuration.

Display Type

Touch Screen

Balance Resolution

Balance Capacity

,

You may also like…

Request a Quote