Two Shops
One Shipment
,

FAMO500 Moisture Analyzer 110g/1mg Touch Screen Motorized


FAMO500 / FAMO501 professional moisture analyzer; 110 / 210 g capacity; 1 mg weighing readability; 0.01% moisture readability; 40–230°C; external calibration; Ø100 mm pan; 7-inch colour touch screen; automatic lifting; serial and USB communication; optional printer and OIML F1 weights.

COLO.SCIENCE — TESTING EQUIPMENT / MOISTURE ANALYZERS — FAMO500 SERIES

FAMO500 professional moisture analyzer with 110–210 g capacity, 1 mg readability and automatic lifting

FAMO500 and FAMO501 are professional thermogravimetric moisture analyzers for controlled Loss on Drying measurements. The series combines 1 mg weighing readability, 0.01% moisture readability, adjustable heating from 40°C to 230°C, a 7-inch high-resolution colour touch screen, automatic lifting and software-supported data collection for routine laboratory moisture analysis.

COLO.SCIENCE — THERMOGRAVIMETRIC LOSS ON DRYING

Integrated weighing, controlled heating and automatic sample-chamber access

The FAMO500 professional moisture analyzer determines moisture by recording the mass of a sample before and during controlled heating. The integrated weighing and heating platform supports a clear four-stage workflow: weigh the sample, apply the selected temperature, monitor mass loss and calculate the moisture result.

Two capacity variants are available: FAMO500 with 110 g capacity and FAMO501 with 210 g capacity. Both provide 1 mg weighing readability, 0.01% moisture readability, external calibration and an Ø100 mm sample pan.

Key characteristics

  • Models: FAMO500 and FAMO501.
  • Capacity: 110 g or 210 g.
  • Weighing readability: 0.001 g / 1 mg.
  • Moisture readability: 0.01%.
  • Temperature range: 40°C to 230°C.
  • Calibration: external.
  • Sample pan: Ø100 mm.
  • Display: 7-inch high-resolution true-colour LCD.
  • Control: capacitive touch screen.
  • Mechanical handling: automatic lifting.

Suitable for

  • Food ingredients, raw materials and finished products.
  • Grains, feed and agricultural samples.
  • Pharmaceutical and chemical quality-control work.
  • Powders, polymers, paper and textile samples.
  • Routine incoming inspection and process verification.
  • Method development with sample-specific temperature and stop criteria.
  • Laboratories requiring touch-screen operation and structured data handling.

FAMO500 SERIES — PROFESSIONAL MOISTURE ANALYZER

FAMO500 professional moisture analyzer for routine laboratory LOD testing

A professional moisture analyzer is selected according to sample type, expected sample mass, required moisture resolution, drying temperature, reporting method and laboratory throughput. The FAMO500 series offers two capacity choices while maintaining the same 1 mg weighing readability and 0.01% moisture readability.

The 40°C to 230°C heating range supports method-based drying for a broad range of materials. Automatic lifting improves access to the heating chamber and sample pan, while the large touch screen provides direct visual control of the measurement process.

For documented laboratory workflows, the instrument can be configured with compatible communication software, an optional thermal printer and optional OIML F1 weights for external calibration and routine control. Final interface compatibility, accessory scope and documentation should be confirmed in the official quotation.

FAMO500 moisture analyzer, optional printer and F1 weights

FAMO500 moisture analyzer for thermogravimetric Loss on Drying measurements

FAMO500 combines weighing, controlled heating, automatic lifting and touch-screen process monitoring in one professional moisture analysis platform.

Optional thermal printer for FAMO500 moisture analyzer measurement records

Optional thermal printer for compatible measurement records when laboratory procedures require direct paper documentation.

Optional OIML F1 calibration weights for FAMO500 moisture analyzer

Optional OIML F1 weights support external calibration, routine balance checks and documented control procedures.

FAMO500 series — model variants and selection parameters

FAMO500

Capacity: 110 g
Weighing readability: 0.001 g / 1 mg
Moisture readability: 0.01%
Repeatability: ±0.2 mg
Linearity: ±0.2 mg
Calibration: External
Sample pan: Ø100 mm
Temperature: 40°C–230°C

FAMO501

Capacity: 210 g
Weighing readability: 0.001 g / 1 mg
Moisture readability: 0.01%
Repeatability: ±0.2 mg
Linearity: ±0.2 mg
Calibration: External
Sample pan: Ø100 mm
Temperature: 40°C–230°C

Model note: confirm the selected capacity, nominal calibration-weight value, printer compatibility, communication interface, software scope and documentation package in the official quotation.

TECHNICAL SPECIFICATIONS — FAMO500 PROFESSIONAL MOISTURE ANALYZER SERIES

Product series FAMO500 / FAMO501
Instrument type Full automatic professional moisture analyzer
Measurement principle Thermogravimetric Loss on Drying
Capacity 110 g / 210 g, depending on model
Weighing readability 0.001 g / 1 mg
Moisture readability 0.01%
Repeatability ±0.2 mg
Linearity ±0.2 mg
Calibration External
Temperature range 40°C–230°C
Sample pan Ø100 mm
Display 7-inch high-resolution true-colour LCD
Control interface Capacitive touch screen
Mechanical handling Automatic lifting mechanism
Communication Serial communication and USB interface
Software Data collection, communication and measurement-process control

Final measurement performance depends on suitable sample preparation, representative sample mass, correct temperature and stop criteria, stable installation, levelling, external calibration, environmental conditions and laboratory method. Final accessories, interfaces, software functions and documentation are confirmed in the official quotation.

STANDARD PACKAGING / STANDARD DELIVERY

Standard FAMO500 package

Included in standard packaging

  • Selected FAMO500 or FAMO501 moisture analyzer.
  • Standard Ø100 mm sample pan components.
  • Power cable / power adapter as supplied.
  • Instruction manual / user documentation.

Optional configuration

  • Compatible thermal printer.
  • OIML F1 calibration and control weights.
  • Communication / data collection software.
  • Certificates and additional documentation.
  • Additional sample pans and consumables, where available.

Moisture measurement workflow and data handling

1. Weigh

Place the prepared sample on the Ø100 mm pan and record the initial sample mass.

2. Heat

Apply the selected drying temperature according to the material and validated laboratory method.

3. Monitor

Track mass loss continuously through the touch-screen interface and process-control software.

4. Result

Calculate and document the moisture result after the selected stop criterion is reached.

OPTIONAL ACCESSORIES AND CALIBRATION SUPPORT

Optional F1 weights, printer and data workflow

The FAMO500 series uses external calibration. Suitable OIML F1 weights may therefore be selected for calibration and routine verification. Printer and software options should be matched to the required laboratory reporting and communication workflow.

OIML F1 calibration weight set for FAMO500 professional moisture analyzer

OIML F1 calibration weights

Used for external calibration, independent routine checks, SOP control points and documented verification of the integrated weighing system.

Optional thermal printer for FAMO500 moisture analyzer

Optional thermal printer

Supports direct printout of compatible moisture and weighing records when required by routine laboratory procedures.

Communication and software

  • Serial communication interface.
  • USB interface.
  • Data collection support.
  • Measurement-process control support.
  • Final compatibility should be confirmed before ordering.

Ordering note: confirm the selected FAMO500 capacity, calibration-weight nominal value, printer compatibility, communication interface, software scope, sample-pan requirements and documentation package in the official quotation.

MOISTURE ANALYZERS

Compare laboratory and agricultural moisture measurement instruments

Explore laboratory moisture analyzers, grain moisture meters and related food and agricultural analysis instruments for routine quality control, incoming inspection and process monitoring.

Open category →

COLO.SCIENCE KNOWLEDGE AND SUPPORT

Selection support for moisture analysis methods and instrument configuration

COLO.Science supports selection of the capacity, sample mass, drying temperature, stop criterion, calibration weights, printer, communication workflow and documentation package for professional moisture analysis.

COLO.Science →

How to select the appropriate FAMO500 model

Start with the total mass placed on the sample pan. FAMO500 provides 110 g capacity for routine small-sample work, while FAMO501 provides 210 g capacity for larger containers, higher sample masses or methods requiring additional tare reserve. Both variants provide the same 1 mg weighing readability and 0.01% moisture readability.

Then define the sample type, expected moisture level, drying temperature, required stop criterion, reporting format and calibration procedure. A representative sample layer and validated method are essential for repeatable moisture results.

Professional moisture analysis with touch-screen control and automatic lifting

FAMO500 is intended for laboratories that need a practical professional moisture analyzer with integrated weighing, controlled heating and continuous mass-loss monitoring. Its 7-inch capacitive touch screen supports direct visual control, while the automatic lifting mechanism provides convenient access to the heating chamber and sample pan.

Reliable results depend not only on instrument specifications but also on sample preparation, sample distribution, drying temperature, stop criteria and calibration practice. COLO.Science can assist with model selection, optional F1 weights, printer and communication configuration according to the intended laboratory workflow.

Configuration notice

FAMO500 and FAMO501 may be supplied with different configurations depending on selected capacity, calibration-weight value, printer, communication interface, software scope, sample-pan accessories, certificates and documentation requirements. The official quotation defines the final delivered configuration. Specifications may change without notice.

Need help selecting a FAMO500 professional moisture analyzer?

Contact COLO.Science to confirm the capacity, sample type, expected sample mass, drying temperature, moisture reporting requirement, calibration weights, printer, software and final delivered configuration.

 

You may also like…

Request a Quote