COLO.SCIENCE — MOBILE AGRICULTURAL QUALITY CONTROL
Fast NIR analysis wherever material decisions are made
FAMO850 combines diffuse-reflectance near-infrared spectroscopy with a cooled InGaAs detector and a portable operating concept. The sample is placed in the 200 ml cup and analysis is started through the connected mobile application.
Thirty scans are completed in approximately 6–10 seconds. Reported parameters depend on the installed calibration model and measured sample matrix.
6–10 s
30 scans per sample
1000–1800 nm
NIR wavelength range
200 ml
Sample volume
Up to 24 h
Battery operation
Key characteristics
- Rapid, nondestructive multi-component NIR analysis.
- 30 scans in approximately 6–10 seconds.
- 1000–1800 nm wavelength range.
- Cooled InGaAs detector.
- Bluetooth and mobile-app operation.
- Up to 24 hours of battery use.
- User-replaceable tungsten-halogen lamp.
Suitable for
- Grain and oilseed receiving inspection.
- Feed and ingredient quality control.
- Mill and processing-line checks.
- Farm, storage and trading-point screening.
- Agricultural trials and field research.
- Raw-material and finished-product comparison.
SELECTION NOTE — FAMO850 CALIBRATION PACKAGE
Calibration-dependent analysis for grain, oilseed and feed
Calibration libraries can support wheat, rice, flour, corn, soybean, soybean meal, cottonseed, rapeseed, sunflower seed, DDGS, compound feed, fish meal and related agricultural materials.
Parameters may include moisture, protein, oil or fat, ash, fiber, starch, dry matter, gluten, calcium, phosphorus, salt and selected amino acids. The exact matrix, range and prediction performance must be confirmed before ordering.
FAMO850 portable NIR measurement workflow
1. Load the sample
Fill the 200 ml cup with the selected and confirmed material.
2. Start measurement
Close the cover and start the method in the mobile application.
3. Complete 30 scans
The analyzer completes 30 scans in approximately 6–10 seconds.
4. Review results
Review parameters supported by the installed calibration model.
TECHNICAL SPECIFICATIONS — FAMO850 MAIN UNIT
Portable NIR analyzer technical data
| Product / SKU | FAMO850 portable NIR analyzer / PRO7084 |
|---|---|
| Measurement principle | Near-infrared spectroscopy, diffuse reflectance |
| Wavelength / detector | 1000–1800 nm / cooled InGaAs detector |
| Light source | Tungsten-halogen lamp; service life >10,000 h; user replaceable |
| Optical bandwidth / SNR | 10.95 ± 0.3 nm @ 1395.5 nm / >10,000:1 |
| Analysis time | 6–10 seconds; 30 scans per sample |
| Repeatability / accuracy | <0.05 nm / ±0.2 nm |
| Sample volume / stray light | 200 ml / <0.1% |
| Dimensions / weight | 220 × 310 × 310 mm / approx. 10 kg without battery |
| Power / battery | 220 V ± 20 V, 50 Hz / up to 24 hours |
| Operating conditions | 0–40 °C; 5–85% relative humidity |
| Communication | Bluetooth; mobile application |
How to configure the FAMO850 portable NIR analyzer
Define the sample matrices, required parameters, expected value ranges, daily measurement volume, operating location and reporting workflow.
COLO.Science can then confirm the calibration package, software access, mobile-device requirements, battery configuration, included accessories and delivery scope.
Configuration notice
Website content supports product selection and does not replace the binding quotation, manufacturer manual or approved calibration documentation. Confirm the calibration package, supported matrices, ranges, software, battery and included accessories before ordering. Specifications may change without notice.
Need help selecting the correct FAMO850 calibration package?
Send the sample materials, required parameters, expected ranges, daily workload and intended operating location. COLO.Science can help confirm the correct configuration.