0–200 NTU · ±2 % + 0.02 NTU · 850 nm LED · ISO 7027

1.150,00€

COLO.Science — Water Quality · Turbidity meters

VIKING257 Benchtop Turbidity Meter

VIKING257 measures turbidity of drinking water, process water and wastewater by the nephelometric (90°) method with a 850 nm LED (ISO 7027): 0–200 NTU, ±2 % of reading + 0.02 NTU, zero and 1–3-point Formazin calibration.

Benchtop Turbidity Meter0–200 NTU±2 % + 0.02 NTU850 nm LEDISO 7027

Overview

Applications

  • Drinking water: turbidity control after filtration and disinfection.
  • Wastewater: influent, effluent and clarifier monitoring.
  • Industry: process water, beverages, pharma and chemicals.
  • Environment: surface water and field sampling.

Why VIKING257

  • Accuracy: ±2 % of reading + 0.02 NTU
  • Calibration: Zero + 1–3 points with Formazin standards
  • Light source: 850 nm LED (ISO 7027)
  • Repeatability: ≤1.0 %

Technical specifications

Model VIKING257
SKU PRO5782
Light source 850 nm LED (ISO 7027)
Measuring principle Nephelometric (90°)
Range (auto) 0.00–20.00 / 20.0–200.0 NTU
Resolution 0.01 / 0.1 NTU
Accuracy ±2 % of reading + 0.02 NTU
Repeatability ≤1.0 %
Stability ±1.0 % FS / 30 min
Units NTU, FNU, EBC
Calibration Zero + 1–3 points with Formazin standards
Power supply Adapter, 200–240 V AC input
Dimensions 330 × 250 × 130 mm
Weight approx. 2.5 kg

ACCESSORIES AND CONSUMABLES

Accessories for the VIKING257

The VIKING257 is delivered with 5 turbidity vials, power adapter. Calibration standards are ordered separately to match the measuring range; spare vials and silicone oil keep the readings reliable.

Turbidity vials, 5 pcs PRO7162

PRO7162

Turbidity vials, 5 pcs

Optical glass sample vials with screw caps; keep them clean and scratch-free, mark the orientation.

Standard delivery

Consumables on request

  • Formazin standards 2 / 20 / 200 NTU
  • Silicone oil and lint-free cloth
  • PRO7162 — Turbidity vials, 5 pcs

Standards, vials and consumables on request. Full catalogue: Electrochemistry catalogue →

Selection guidance

VIKING257 is chosen for simple low-range laboratory checks up to 200 NTU. COLO.Science helps you choose standards and vials.

Configuration checklist

  • Range: low turbidity (drinking water) or up to 200 NTU (wastewater).
  • Standard: ISO 7027 (LED) or US EPA 180.1 (tungsten lamp).
  • Place of use: laboratory bench or field (IP65 portable).
  • Calibration: weekly in routine work or before critical tests, from the lowest to the highest standard, then verification.

Sales and support for international customers

COLO Lab ExpertsPolje ob Sotli 4, SI-3255 Buče, Slovenia
Phone: +386 70 713 437 · Email: sales@colo.si · Web: colo.si
We supply laboratories across Europe directly and through partners. B2B prices are quoted net, excluding VAT.

Need help choosing the right VIKING257 benchtop turbidity meter configuration?

Tell us the sample type, the expected turbidity and the standard you report by. COLO.Science will confirm the VIKING257 configuration, standards and vials.

Measurement Parameters

Turbidity

Instrument Type

Benchtop

Request a Quote