VIKING-M600 is a touchscreen benchtop multi-parameter analyzer for laboratory measurement of pH, mV / ORP, pX, ion concentration (ISE), conductivity, resistivity, TDS, salinity, dissolved oxygen and temperature. With a 7.0″ color touch LCD, modular measurement channels, GLP-compliant data storage and advanced calibration functions, VIKING-M600 is designed for water quality laboratories, environmental monitoring, industrial QC, education and research applications.
7.0″ touch LCD
pH / ISE / EC / DO
pH ±0.002
EC to 3000 mS/cm
GLP data storage
IP54

COLO.SCIENCE — WATER QUALITY / LABORATORY ELECTROCHEMISTRY
Benchtop multi-parameter platform for pH, ISE, conductivity and dissolved oxygen
The VIKING-M600 Multi-Parameter Analyzer is designed for laboratories that need several electrochemical measurements on one bench instrument. It supports pH, mV / ORP, pX, ion concentration, conductivity, resistivity, TDS, salinity, dissolved oxygen and temperature measurement in a single modular system.
The instrument includes a large touchscreen interface, configurable measurement channels, advanced calibration functions, GLP data management and communication options for documentation, review and export of laboratory results.
Key features
- 7.0″ color touchscreen LCD with intuitive instrument operation.
- pH, ISE, conductivity and dissolved oxygen measurement support.
- pH accuracy ±0.002 pH with up to 6-point calibration.
- Conductivity range up to 3000 mS/cm with resistivity, TDS and salinity support.
- Dissolved oxygen measurement with automatic barometric pressure compensation.
- GLP-compliant data storage with 1000 result sets per parameter.
Suitable for
- Drinking water, wastewater and process water laboratories.
- Environmental monitoring and field-sample confirmation workflows.
- Industrial quality control in chemical, food and beverage applications.
- Research laboratories requiring flexible electrochemical methods.
- Teaching laboratories for pH, conductivity, ISE and DO measurement principles.
- Routine laboratory workflows where traceable multi-parameter results are required.
TECHNICAL SPECIFICATIONS — VIKING-M600 MULTI-PARAMETER ANALYZER
| Model | VIKING-M600 |
| Product type | Benchtop multi-parameter analyzer for laboratory electrochemistry |
| Measured parameters | pH, mV, ORP, pX, ISE, EC, resistivity, TDS, salinity, dissolved oxygen, % saturation and temperature |
| Display | 7.0″ color LCD touchscreen with backlight |
| pH range / resolution / accuracy | −2.000 to 20.000 pH / 0.1, 0.01, 0.001 pH / ±0.002 pH |
| pH calibration | Up to 6 points; NIST, GB and DIN buffer recognition; custom buffer group supported |
| mV / ORP range | −2000.00 to 2000.00 mV; accuracy ±0.1 mV or ±0.03% |
| pX range / accuracy | −2.000 to 20.000 pX / ±0.002 pX |
| ISE range / units | 1.000e−9 to 9.999e+9; mol/L, mmol/L, g/L, mg/L, μg/L and related units |
| ISE modes | Direct Reading, Standard Addition, Sample Addition, GRAN and user methods |
| Conductivity range / accuracy | 0.000 μS/cm to 3000 mS/cm / ±0.5% FS |
| Conductivity calibration | Up to 5 points; standard recognition for 146.5 μS/cm, 1408 μS/cm, 12.85 mS/cm and 111.3 mS/cm |
| Resistivity | 5.00 Ω·cm to 100.0 MΩ·cm |
| TDS | 0.000 mg/L to 1000 g/L |
| Salinity | 0.00–8.00 % NaCl; accuracy ±0.1% |
| Dissolved oxygen | 0.00 to 99.99 mg/L; resolution 0.01 mg/L; accuracy ±0.1 mg/L |
| DO % saturation | 0.0 to 600%; accuracy ±2.0% |
| Temperature range / accuracy | −5 to 130°C; 0.1°C resolution; ±0.1°C accuracy |
| Reading modes | Auto-read, timed-read and continuous-read |
| Data storage | 1000 result groups per parameter; GLP features and log management |
| Inputs / outputs | BNC Q9 pH electrode input; 6-pin Mini-DIN DO + temperature; 8-pin Mini-DIN conductivity + temperature; USB and RS-232 |
| Housing | IP54 splash-resistant housing |
| Power supply | AC adapter, 100–240 V AC input, 24 V DC output |
| Dimensions / net weight | 280 × 280 × 130 mm / 2500 g |
| HTML TechSpec | Open VIKING-M600 technical specification |
Final configuration, supplied electrodes, optional ISE methods, calibration standards and accessories should be confirmed according to laboratory application, sample type and required measurement parameters.
Measurement modules and laboratory workflow support
VIKING-M600 combines several electrochemical measurement workflows in one bench-top platform. The instrument can be configured for routine pH and ORP measurement, conductivity and salinity control, ion-selective analysis and dissolved oxygen monitoring. This reduces the need for multiple separate instruments when a laboratory frequently works with water quality, environmental, process or research samples.
pH / ORP / pX / ISE
High-accuracy pH, mV, ORP, pX and ion-selective workflows with multi-point calibration and method support.
Conductivity / TDS / salinity
Conductivity range up to 3000 mS/cm with resistivity, TDS and %NaCl salinity measurement support.
Dissolved oxygen
Polarographic DO measurement with automatic barometric pressure compensation and salinity correction.
GLP data handling
Data storage, review, comparison, recalculation and communication functions for traceable laboratory records.
COLO.SCIENCE KNOWLEDGE
Water quality and electrochemical measurement in practice
Explore COLO.Science resources covering pH, conductivity, dissolved oxygen and multi-parameter water quality analysis for laboratory and industrial applications.
VIKING M600 benchtop multiparameter analyzer | COLO.Science
Applications and laboratory value
Water quality laboratories
VIKING-M600 supports routine bench measurement of drinking water, wastewater, process water and environmental samples where pH, conductivity, salinity and dissolved oxygen are commonly required.
Industrial quality control
The analyzer is useful for chemical, food, beverage and process laboratories that require repeatable electrochemical measurements and documented results.
Research and education
Multiple measurement channels and guided methods make VIKING-M600 suitable for teaching electrochemistry principles and for flexible research workflows.
Traceable documentation
GLP data handling, result storage, communication ports and printer / PC support help laboratories document measurements in a structured way.
How to choose the correct VIKING-M600 configuration
When selecting a benchtop multi-parameter analyzer, the laboratory should define which parameters are needed routinely: pH, ORP, ion-selective measurement, conductivity, TDS, salinity, dissolved oxygen or temperature. VIKING-M600 is most useful when several of these measurements must be performed in one central laboratory station.
Electrode selection is critical. The final configuration should be matched to sample matrix, required measurement range, accuracy expectations, calibration standards, connector type, temperature compensation and documentation requirements. Optional ISE electrodes, standards and consumables should be selected according to the ions and methods required by the laboratory.
VIKING-M600 as a benchtop multi-parameter analyzer for daily laboratory work
VIKING-M600 Multi-Parameter Analyzer is useful when a laboratory needs one bench instrument for several electrochemical measurements. Instead of using separate instruments for pH, conductivity and dissolved oxygen, the user can centralize multiple measurement routines on one touchscreen analyzer with method management and result storage.
The combination of pH, ISE, conductivity, salinity, TDS, dissolved oxygen and temperature measurement makes VIKING-M600 especially relevant for water quality analysis, environmental monitoring, process water control and laboratory education. GLP-style data management, calibration functions and connectivity support help laboratories maintain repeatable measurement workflows and clear documentation.
Product video — coming soon
This block is reserved for the future VIKING-M600 product video, demonstration or configuration guide. When the video is ready, the button in the hero section can be linked directly to the video URL or embedded player.
Configuration notice — electrodes and accessories should be confirmed before quotation
Multi-parameter analyzers are typically configured according to required measurement parameters, electrode type, sample matrix, calibration standards, laboratory workflow and documentation requirements.
Available electrodes, ISE options, compatible probes and technical accessories should be confirmed before quotation.
The content shown on this website is provided for general information and may not represent the final delivered configuration.
VIKING-M600 — benchtop multi-parameter analyzer for water quality and electrochemistry
A touchscreen multi-parameter analyzer for pH, mV / ORP, pX, ISE, conductivity, resistivity, TDS, salinity, dissolved oxygen and temperature — with 7.0″ touch LCD, GLP data storage, modular measurement channels and support from COLO.Science.