COLO.Science — Electrochemistry · multi-parameter analyzers
VIKING-M300A Benchtop Multi-parameter Analyzer
VIKING-M300A is a benchtop multi-parameter analyzer for pH, conductivity, ion concentration and temperature in one instrument. It combines a 7.0″ backlit LCD, pH ±0.01 pH, conductivity ±1.0 % FS, ISE ±0.5 %, 500-result GLP memory and IP54 protection.
Overview
Applications
- Water and wastewater: pH, conductivity, ions in drinking, surface and waste water.
- Environment and aquaculture: monitoring of rivers, lakes, wells and fish farms.
- Food, pharma and industry: process water, solutions and quality control.
- Education and research: several methods on one instrument instead of several meters.
Why VIKING-M300A
- One instrument: pH / EC / ISE / Temperature with separate electrode inputs.
- Clear display: 7.0″ LCD with backlight with Reading / Stable / Locked prompts.
- Calibration: pH up to 5 points with buffer recognition, conductivity up to 3 points, ions up to 5 points.
- Data traceability: 500 results per parameter, GLP; USB (PC), RS-232 (printer).
Technical specifications
| Model | VIKING-M300A |
| SKU | PRO5384 |
| pH range / accuracy | −2.00 to 20.00 pH; ±0.01 pH |
| pH calibration | up to 5 points; NIST, DIN, GB, USA, GOST |
| mV range / accuracy | −2000.0 to 2000.0 mV; ±0.3 mV or ±0.1 % |
| pX range / accuracy | −2.00 to 20.00 pX; ±0.01 pX |
| Ion range / accuracy | 1.000e-9 to 9.999e+9; ±0.5 % |
| Ion calibration | up to 5 points |
| Conductivity range / accuracy | 0.000 µS/cm to 1000 mS/cm; ±1.0 % FS |
| Conductivity calibration | up to 3 points |
| Resistivity range | 5.00 Ω·cm to 20.00 MΩ·cm |
| TDS range | 0.00 ppm to 300 ppt |
| Salinity | NaCl, 0.0 to 80.0 ppt, ±2 ppt |
| Temperature range / accuracy | −5 to 110 °C / 23 to 230 °F; ±0.2 °C |
| Temperature compensation | ATC / MTC |
| Reading modes | AutoRead (fast / medium / slow), timed, continuous |
| Display | 7.0″ LCD with backlight |
| Data memory | 500 results per parameter, GLP |
| Inputs | BNC (pH / ISE), banana (reference), 4-pin (temperature / DO), 5-pin (conductivity) |
| Outputs | USB (PC), RS-232 (printer) |
| Auto power-off | 1–60 min or off |
| Power supply | Power adapter, DC 20 V |
| Protection | IP54 |
| Dimensions | 242 × 195 × 68 mm |
| Weight | approx. 900 g |
ELECTRODES AND ACCESSORIES
Electrodes and accessories for the VIKING-M300A benchtop multi-parameter analyzer
The VIKING-M300A is delivered with a 3-in-1 pH electrode, a conductivity electrode, pH buffers and a conductivity standard. Ion-selective electrodes, standards and ISA solutions are chosen per ion.
PRO4153
3-in-1 pH composite electrode E-301-QC
pH + reference + temperature in one body; Ag/AgCl, 0–14 pH, BNC (Q9) and 4-pin connector.
Standard delivery
PRO6154
Conductivity electrode DJS-1VTC (k = 1, ATC)
2–20000 µS/cm, glass body, with temperature sensor, 0–80 °C, Φ12×120 mm; 5-pin connector.
Standard delivery
PRO6122
pH buffer set 4.01 / 7.00 / 10.01
Standard pH buffer solutions, 50 mL each, for 3-point calibration.
Standard delivery
PRO7007
Conductivity standard 1413 µS/cm, 50 mL
Calibration standard at 25 °C for cell-constant calibration.
Standard delivery
COLO-5
Electrode stand COLO-5
Flexible electrode arm with 360° rotation; holds the electrode above the beaker.
Standard delivery
PRO6237
Fluoride combined ISE PF-202-C
Fluoride (F⁻) ion-selective electrode with built-in reference, BNC (Q9).
Optional
More electrodes and accessories
- PRO6998 — Thermal printer 771000
- PRO6242 — Chloride (Cl⁻) ISE
- PRO6249 — Nitrate (NO₃⁻) ISE
- PRO7128 — Fluoride ISE standard 0.1 mol/L, 250 mL
- PRO6163 — Polarographic DO electrode DO-958-Q
Tell us your sample and we will confirm the right electrode for your VIKING-M300A benchtop multi-parameter analyzer. Full electrode range: Electrochemistry catalogue →
Selection guidance
VIKING-M300A is chosen when several water parameters are measured routinely and one instrument should replace separate meters. COLO.Science helps you choose electrodes, standards and ISA solutions.
Configuration checklist
- Parameters: which of pH, EC, ions and DO you need to measure.
- Place of use: field (portable, IP65 / IP67) or laboratory bench.
- Ions: which ion-selective electrodes and standards.
- Documentation: GLP records, USB export or printer.
- Need more?: see VIKING-MPA300.
Sales and support for international customers
COLO Lab ExpertsPolje ob Sotli 4, SI-3255 Buče, Slovenia
Phone: +386 70 713 437 · Email: sales@colo.si · Web: colo.si
We supply laboratories across Europe directly and through partners. B2B prices are quoted net, excluding VAT.