Two Shops
One Shipment

VIKING-EC400 Laboratory Conductivity Meter


COLO.Science · Benchtop Conductivity Meter

EC 0.000 µS/cm…1000 mS/cm · ±0.5 % FS · Resistivity to 100.0 MΩ·cm · Calibration 1–3 points · IP54

685,00€

COLO.Science — Electrochemistry · conductivity meters

VIKING-EC400 Benchtop Conductivity Meter

VIKING-EC400 is a high-accuracy benchtop conductivity meter (±0.5 % FS) for conductivity, resistivity up to 100 MΩ·cm, TDS, salinity and temperature, with GLP memory, USB and RS-232. It combines a 7.0″ backlit LCD, conductivity measurement from 0.000 µS/cm to 1000 mS/cm (±0.5 % FS), 1- to 3-point calibration with automatic standard recognition, automatic / manual temperature compensation, a 500-result memory (GLP), USB and RS-232 connectivity and IP54 protection.

Benchtop conductivity meterECResistivityTDSSalinity7.0″ LCD±0.5 % FSCalibration 1–3 pointsGLPUSBIP54

Overview

Applications

  • Water quality: drinking water, wastewater, surface and process water.
  • Purified water: resistivity and conductivity of deionised, RO and laboratory water.
  • Laboratory QC: routine release testing of water, solutions and raw materials.
  • Food, aquaculture and industry: salinity, TDS and conductivity of brines, rinse water and process solutions.

Why VIKING-EC400

  • Clear display: 7.0″ LCD with backlight with Reading / Stable prompts.
  • Calibration: 1–3 points with automatic recognition of 84 µS/cm, 1413 µS/cm, 12.88 mS/cm.
  • Stable bench setup: electrode stand with 360° arm keeps the cell in position during measurement.
  • Data traceability: 500 results stored per parameter with date, time and GLP records.

Technical specifications

Model VIKING-EC400
SKU PRO2747
Conductivity range 0.000 µS/cm to 1000 mS/cm
Conductivity resolution 0.001 µS/cm minimum, auto range
Conductivity accuracy ±0.5 % FS
Reference temperature 20 / 25 °C
Calibration 1–3 points, standard recognition
Recognised standards 84 µS/cm, 1413 µS/cm, 12.88 mS/cm
Settable parameters Cell constant, temperature coefficient, TDS factor
Compensation type None, linear, pure water
Resistivity range 5.00 Ω·cm to 100.0 MΩ·cm
Resistivity accuracy ±0.5 % FS
TDS range 0.000 ppm to 1000 ppt
TDS accuracy ±0.5 % FS
Salinity (NaCl) 0.0 to 80.0 ppt, 0.1 ppt, ±1 ppt
Temperature range −10 to 135 °C / 14 to 275 °F
Temperature accuracy ±0.1 °C
Temperature compensation ATC / MTC
Reading modes AutoRead (fast / medium / slow), timed, continuous
Reading prompts Reading, Stable, Locked
Display 7.0″ LCD with backlight
Data memory 500 results per parameter, GLP
Electrode input 5-pin connector (conductivity + temperature)
Outputs USB (PC), RS-232 (printer)
Auto power-off 1–60 min or off
Power supply Power adapter, DC 20 V
Protection IP54
Dimensions 242 × 195 × 68 mm
Weight approx. 900 g

COLO.SCIENCE VIDEO

VIKING-EC400 operation video

Installation, settings, cell constant calibration and measurement — step by step.

VIKING-EC400 operation video (4:42). Open the video in a new window

ELECTRODES AND ACCESSORIES

Electrodes and accessories for the VIKING-EC400 benchtop conductivity meter

The VIKING-EC400 is delivered with the conductivity electrode DJS-1VTC (k = 1, ATC, 5-pin connector), the 1413 µS/cm standard and electrode stand COLO-5. Electrodes with k = 0.1, 0.01 and 10 and standards from 84 µS/cm to 111.3 mS/cm extend the range from ultrapure water to brines.

Conductivity electrode DJS-1VTC (k = 1, ATC) PRO6154

PRO6154

Conductivity electrode DJS-1VTC (k = 1, ATC)

2–20000 µS/cm, glass body, with temperature sensor, 0–80 °C, Φ12×120 mm; 5-pin connector.

Standard delivery

Conductivity standard 1413 µS/cm, 50 mL PRO7007

PRO7007

Conductivity standard 1413 µS/cm, 50 mL

Calibration standard at 25 °C for cell-constant calibration.

Standard delivery

Electrode stand COLO-5 COLO-5

COLO-5

Electrode stand COLO-5

Flexible electrode arm with 360° rotation; holds the electrode above the beaker.

Standard delivery

Conductivity electrode DJS-1VTG (k = 1, ATC) PRO6156

PRO6156

Conductivity electrode DJS-1VTG (k = 1, ATC)

2–3000 µS/cm, glass body, with temperature sensor, 0–80 °C, Φ12×120 mm; 5-pin connector.

Optional

Conductivity electrode DJS-0.1VTG (k = 0.1, ATC) PRO6157

PRO6157

Conductivity electrode DJS-0.1VTG (k = 0.1, ATC)

0.05–200 µS/cm, glass body, with temperature sensor, 0–80 °C, Φ12×120 mm; 5-pin connector.

Optional

Conductivity electrode DJS-0.01VT (k = 0.01, ATC) PRO6158

PRO6158

Conductivity electrode DJS-0.01VT (k = 0.01, ATC)

0.05–20 µS/cm, titanium alloy, with temperature sensor, 0–60 °C, Φ18×50 mm; 5-pin connector.

Optional

Conductivity electrode DJS-10VTC (k = 10, ATC) PRO6160

PRO6160

Conductivity electrode DJS-10VTC (k = 10, ATC)

2000–200000 µS/cm, glass body, with temperature sensor, 0–80 °C, Φ12×120 mm; 5-pin connector.

Optional

Conductivity electrode DJS-0.01VT (k = 0.01, ATC), flow cell PRO6159

PRO6159

Conductivity electrode DJS-0.01VT (k = 0.01, ATC), flow cell

0.05–20 µS/cm, titanium alloy, with temperature sensor, 0–60 °C, removable flow cell; 5-pin connector.

Optional

More electrodes and accessories

  • PRO6998 — Thermal printer 771000
  • PRO6130 — Conductivity standard 1413 µS/cm, 250 mL
  • PRO6132 — Conductivity standard 84 µS/cm, 250 mL
  • PRO6131 — Conductivity standard 146.5 µS/cm, 250 mL
  • PRO6129 — Conductivity standard 12.85 mS/cm, 250 mL

Tell us your sample and we will confirm the right electrode for your VIKING-EC400 benchtop conductivity meter. Full electrode range: Electrochemistry catalogue →

Selection guidance

VIKING-EC400 is chosen where ±0.5 % FS accuracy and resistivity up to 100 MΩ·cm are needed, e.g. for purified and pharmaceutical water, with GLP records and printer output. COLO.Science helps you choose the electrode and standards.

Configuration checklist

  • Sample type: drinking, waste, pure or process water, solutions, brines.
  • Range: expected conductivity decides the cell constant (k = 0.01 / 0.1 / 1 / 10).
  • Calibration: number of points and standards close to the sample value.
  • Documentation: memory, GLP records, USB export or printer.
  • Need more?: see VIKING-EC500.

Sales and support for international customers

COLO Lab ExpertsPolje ob Sotli 4, SI-3255 Buče, Slovenia
Phone: +386 70 713 437 · Email: sales@colo.si · Web: colo.si
We supply laboratories across Europe directly and through partners. B2B prices are quoted net, excluding VAT.

Need help choosing the right VIKING-EC400 benchtop conductivity meter configuration?

Tell us the sample type, conductivity range and how you document results. COLO.Science will confirm the electrode, standards and VIKING-EC400 configuration for your workflow.

SKU: PRO2747 Category: Tag:
Measurement Parameters

Conductivity

Instrument Type

Benchtop

Request a Quote