COLO.Science — Electrochemistry · conductivity meters
VIKING-EC400 Benchtop Conductivity Meter
VIKING-EC400 is a high-accuracy benchtop conductivity meter (±0.5 % FS) for conductivity, resistivity up to 100 MΩ·cm, TDS, salinity and temperature, with GLP memory, USB and RS-232. It combines a 7.0″ backlit LCD, conductivity measurement from 0.000 µS/cm to 1000 mS/cm (±0.5 % FS), 1- to 3-point calibration with automatic standard recognition, automatic / manual temperature compensation, a 500-result memory (GLP), USB and RS-232 connectivity and IP54 protection.
Overview
Applications
- Water quality: drinking water, wastewater, surface and process water.
- Purified water: resistivity and conductivity of deionised, RO and laboratory water.
- Laboratory QC: routine release testing of water, solutions and raw materials.
- Food, aquaculture and industry: salinity, TDS and conductivity of brines, rinse water and process solutions.
Why VIKING-EC400
- Clear display: 7.0″ LCD with backlight with Reading / Stable prompts.
- Calibration: 1–3 points with automatic recognition of 84 µS/cm, 1413 µS/cm, 12.88 mS/cm.
- Stable bench setup: electrode stand with 360° arm keeps the cell in position during measurement.
- Data traceability: 500 results stored per parameter with date, time and GLP records.
Technical specifications
| Model | VIKING-EC400 |
| SKU | PRO2747 |
| Conductivity range | 0.000 µS/cm to 1000 mS/cm |
| Conductivity resolution | 0.001 µS/cm minimum, auto range |
| Conductivity accuracy | ±0.5 % FS |
| Reference temperature | 20 / 25 °C |
| Calibration | 1–3 points, standard recognition |
| Recognised standards | 84 µS/cm, 1413 µS/cm, 12.88 mS/cm |
| Settable parameters | Cell constant, temperature coefficient, TDS factor |
| Compensation type | None, linear, pure water |
| Resistivity range | 5.00 Ω·cm to 100.0 MΩ·cm |
| Resistivity accuracy | ±0.5 % FS |
| TDS range | 0.000 ppm to 1000 ppt |
| TDS accuracy | ±0.5 % FS |
| Salinity (NaCl) | 0.0 to 80.0 ppt, 0.1 ppt, ±1 ppt |
| Temperature range | −10 to 135 °C / 14 to 275 °F |
| Temperature accuracy | ±0.1 °C |
| Temperature compensation | ATC / MTC |
| Reading modes | AutoRead (fast / medium / slow), timed, continuous |
| Reading prompts | Reading, Stable, Locked |
| Display | 7.0″ LCD with backlight |
| Data memory | 500 results per parameter, GLP |
| Electrode input | 5-pin connector (conductivity + temperature) |
| Outputs | USB (PC), RS-232 (printer) |
| Auto power-off | 1–60 min or off |
| Power supply | Power adapter, DC 20 V |
| Protection | IP54 |
| Dimensions | 242 × 195 × 68 mm |
| Weight | approx. 900 g |
COLO.SCIENCE VIDEO
VIKING-EC400 operation video
Installation, settings, cell constant calibration and measurement — step by step.
VIKING-EC400 operation video (4:42). Open the video in a new window
ELECTRODES AND ACCESSORIES
Electrodes and accessories for the VIKING-EC400 benchtop conductivity meter
The VIKING-EC400 is delivered with the conductivity electrode DJS-1VTC (k = 1, ATC, 5-pin connector), the 1413 µS/cm standard and electrode stand COLO-5. Electrodes with k = 0.1, 0.01 and 10 and standards from 84 µS/cm to 111.3 mS/cm extend the range from ultrapure water to brines.
PRO6154
Conductivity electrode DJS-1VTC (k = 1, ATC)
2–20000 µS/cm, glass body, with temperature sensor, 0–80 °C, Φ12×120 mm; 5-pin connector.
Standard delivery
PRO7007
Conductivity standard 1413 µS/cm, 50 mL
Calibration standard at 25 °C for cell-constant calibration.
Standard delivery
COLO-5
Electrode stand COLO-5
Flexible electrode arm with 360° rotation; holds the electrode above the beaker.
Standard delivery
PRO6156
Conductivity electrode DJS-1VTG (k = 1, ATC)
2–3000 µS/cm, glass body, with temperature sensor, 0–80 °C, Φ12×120 mm; 5-pin connector.
Optional
PRO6157
Conductivity electrode DJS-0.1VTG (k = 0.1, ATC)
0.05–200 µS/cm, glass body, with temperature sensor, 0–80 °C, Φ12×120 mm; 5-pin connector.
Optional
PRO6158
Conductivity electrode DJS-0.01VT (k = 0.01, ATC)
0.05–20 µS/cm, titanium alloy, with temperature sensor, 0–60 °C, Φ18×50 mm; 5-pin connector.
Optional
PRO6160
Conductivity electrode DJS-10VTC (k = 10, ATC)
2000–200000 µS/cm, glass body, with temperature sensor, 0–80 °C, Φ12×120 mm; 5-pin connector.
Optional
PRO6159
Conductivity electrode DJS-0.01VT (k = 0.01, ATC), flow cell
0.05–20 µS/cm, titanium alloy, with temperature sensor, 0–60 °C, removable flow cell; 5-pin connector.
Optional
More electrodes and accessories
- PRO6998 — Thermal printer 771000
- PRO6130 — Conductivity standard 1413 µS/cm, 250 mL
- PRO6132 — Conductivity standard 84 µS/cm, 250 mL
- PRO6131 — Conductivity standard 146.5 µS/cm, 250 mL
- PRO6129 — Conductivity standard 12.85 mS/cm, 250 mL
Tell us your sample and we will confirm the right electrode for your VIKING-EC400 benchtop conductivity meter. Full electrode range: Electrochemistry catalogue →
Selection guidance
VIKING-EC400 is chosen where ±0.5 % FS accuracy and resistivity up to 100 MΩ·cm are needed, e.g. for purified and pharmaceutical water, with GLP records and printer output. COLO.Science helps you choose the electrode and standards.
Configuration checklist
- Sample type: drinking, waste, pure or process water, solutions, brines.
- Range: expected conductivity decides the cell constant (k = 0.01 / 0.1 / 1 / 10).
- Calibration: number of points and standards close to the sample value.
- Documentation: memory, GLP records, USB export or printer.
- Need more?: see VIKING-EC500.
Sales and support for international customers
COLO Lab ExpertsPolje ob Sotli 4, SI-3255 Buče, Slovenia
Phone: +386 70 713 437 · Email: sales@colo.si · Web: colo.si