Two Shops
One Shipment

VIKING-DO511 Touch screen Portable DO Meter


COLO.Science · Portable DO Meter

DO 0.00…20.00 mg/L · ±0.3 mg/L · Saturation 0.0–200.0 % · Optical (luminescence) · IP67

1.250,00€

COLO.Science — Electrochemistry · DO meters

VIKING-DO511 Portable DO Meter

VIKING-DO511 is a portable touchscreen dissolved oxygen meter with an optical (luminescence) sensor — no electrolyte, no membrane change and no oxygen consumption — with GLP memory, USB 2.0, Bluetooth and IP67 protection. It combines a 4.3″ colour touchscreen, DO measurement from 0.00 to 20.00 mg/L (±0.3 mg/L), saturation 0.0–200.0 %, air-saturated water or zero-oxygen calibration, barometric and salinity correction, a 1000-result memory (GLP), USB and Bluetooth connectivity and IP67 protection.

Portable DO MeterDO (mg/L)SaturationTemperature4.3″ touchscreen±0.3 mg/LOptical (luminescence)ATC / MTCGLPUSBIP67

Overview

Applications

  • Wastewater treatment: aeration control, activated sludge and effluent checks.
  • Aquaculture and environment: fish farms, rivers, lakes and monitoring points.
  • Field and on-site: compact IP67 housing for sampling points and plants.
  • Food, beverages and process water: oxygen in process water, fermentation and quality control.

Why VIKING-DO511

  • Clear display: 4.3″ colour touchscreen with guided menus for measurement, calibration and data.
  • Sensor: optical sensor: no electrolyte, no membrane change, no polarisation time.
  • Corrections: barometric pressure and salinity factor for accurate mg/L in any sample.
  • Data traceability: 1000 results stored per parameter with date, time and GLP records.

Technical specifications

Model VIKING-DO511
SKU PRO2427
Sensor type Optical (luminescence)
DO range 0.00 to 20.00 mg/L
DO resolution 0.01 mg/L
DO accuracy ±0.3 mg/L
Saturation range 0.0–200.0 %
Saturation accuracy ±10.0 %
Units mg/L (ppm), %
Calibration Air-saturated water or zero oxygen
Pressure Barometric pressure compensation
Salinity correction Manual salinity factor correction
Temperature range 0 to 50 °C
Temperature accuracy ±0.1 °C
Temperature compensation ATC / MTC
Reading modes AutoRead (fast / medium / slow), timed, continuous
Reading prompts Reading, Stable, Locked
Display 4.3″ colour touchscreen
Data memory 1000 results per parameter, GLP
Management Users, calibration, electrodes, methods, data analysis
Electrode input 4-pin connector (DO + temperature)
Outputs USB 2.0 (flash drive, PC, scanner), Bluetooth
Auto power-off 300 / 600 / 1200 / 1800 / 3600 s or off
Power supply Rechargeable Li battery; adapter 100–240 V AC / 5 V DC
Protection IP67
Dimensions 90 × 255 × 40 mm
Weight approx. 500 g

COLO.SCIENCE VIDEO

VIKING-DO511 operation video

Installation, settings, calibration and DO measurement — step by step.

VIKING-DO511 operation video (4:16). Open the video in a new window

ELECTRODES AND ACCESSORIES

Electrodes and accessories for the VIKING-DO511 portable DO meter

The VIKING-DO511 is delivered with the optical DO electrode (luminescence) (PRO6164), which measures dissolved oxygen and temperature through the 4-pin connector. The optical sensor needs no electrolyte or membrane change.

VIKING-DO511 Touch screen Portable DO Meter

PRO6164

Optical DO electrode (luminescence)

DO + temperature, 0.00–20.00 mg/L, no electrolyte and no membrane change, POM body, Φ16×150 mm, 4-pin connector, 3 m cable.

Standard delivery

Zero-oxygen calibration powder (100 mL) —

—

Zero-oxygen calibration powder (100 mL)

Prepares the zero-oxygen solution for zero-point calibration.

Standard delivery

Silicone protective case and wristband —

—

Silicone protective case and wristband

Shock-absorbing silicone sleeve and wristband for safe one-hand field use.

Standard delivery

Carrying case PRO7006

PRO7006

Carrying case

Protective case for the meter, electrode and buffers in field use.

Standard delivery

Polarographic DO electrode DO-958-Q PRO6163

PRO6163

Polarographic DO electrode DO-958-Q

DO + temperature, 0–20 mg/L (0–50 mg/L on dedicated meters), ABS body, 5–40 °C, Φ12×120 mm, 4-pin connector, 1 m cable.

Optional

More electrodes and accessories

  • Zero-oxygen calibration powder (100 mL)

Tell us your sample and we will confirm the right electrode for your VIKING-DO511 portable DO meter. Full electrode range: Electrochemistry catalogue →

Selection guidance

VIKING-DO511 is chosen where maintenance must be minimal: the optical sensor needs no electrolyte or membrane change, does not consume oxygen and is ready to measure without polarisation time. COLO.Science helps you choose the electrode and consumables.

Configuration checklist

  • Sample type: wastewater, surface water, aquaculture, BOD bottles, process water.
  • Range: expected DO and saturation (supersaturated samples need a wider range).
  • Sensor: polarographic (low cost) or optical (low maintenance).
  • Documentation: memory, GLP records, USB export or printer.
  • Need more?: see VIKING-DO600.

Sales and support for international customers

COLO Lab ExpertsPolje ob Sotli 4, SI-3255 Buče, Slovenia
Phone: +386 70 713 437 · Email: sales@colo.si · Web: colo.si
We supply laboratories across Europe directly and through partners. B2B prices are quoted net, excluding VAT.

Need help choosing the right VIKING-DO511 portable DO meter configuration?

Tell us the sample type, the expected oxygen level and how you document results. COLO.Science will confirm the electrode, consumables and VIKING-DO511 configuration for your workflow.

SKU: PRO2427 Category:
Measurement Parameters

Conductivity

Instrument Type

Benchtop

Standard packing:

EC electrode
1413μS/cm EC standard
solution, 50ml, 1 vial
COLO-5 electrode stand

Request a Quote