COLO.Science · Shakers & Mixers · Roller mixers
ROMIX70 blood roller mixer — 6 rollers, 20–99 rpm, rolling and swinging action
The ROMIX70 is a digital blood roller mixer for haematology, blood banking and general laboratory work. Six rollers turn the tube while the deck swings, so whole blood, viscous substances and liquid–solid suspensions are mixed completely without shear. Speed and time are set digitally on independent LED displays and the brushless DC motor is maintenance-free. Product code PRO4582.
Rolling and swinging on six rollers
A blood roller mixer is chosen when the sample has to stay homogeneous over time and must not be damaged. The ROMIX70 combines two motions in one deck: the six rollers rotate the tube around its own axis while the whole deck swings with a 25 mm amplitude. The sample is turned over completely, without foaming and without the shear a vortex would apply — which is exactly what whole blood requires.
Key characteristics
- Six rollers, 280 mm long, for tubes and bottles from 8 mm to 200 mm.
- Rolling and swinging combined, swinging amplitude 25 mm.
- Speed 20–99 rpm, set digitally, with an independent LED display.
- Timer 1 min to 99 h 59 min, or continuous running.
- Programmable forward / reverse motion, interval 30 s to 99 min 59 s.
- Maximum load 4 kg on the open deck.
- Brushless DC motor, maintenance-free, quiet enough for the bench.
- Wide-range supply, AC 100–240 V, 50–60 Hz, 15 W.
Suitable for
- Haematology and blood bank laboratories mixing whole blood before analysis.
- Prevention of coagulation in sample tubes waiting for the analyser.
- Immune precipitation and antibody–antigen incubation in closed tubes.
- Resuspension of viscous substances and liquid–solid suspensions.
- Roller-bottle work and gentle long-duration mixing in research laboratories.
Why a blood roller mixer and not a vortex
Whole blood is the classic case for a blood roller mixer. Vortexing would haemolyse the sample; leaving the tube on the bench lets the cells settle and the clotting cascade begin. Slow, continuous rolling keeps erythrocytes in suspension and the anticoagulant evenly distributed, so the result the analyser reports is the result the patient actually has. The same principle applies wherever a sample has to be held ready rather than mixed once: a laboratory roller mixer keeps the tube in motion for hours at a speed low enough to leave the cells intact.
The ROMIX70 tube roller mixer covers that duty with six rollers and a combined rolling and swinging motion. Where the protocol instead requires mixing at a controlled temperature, the instrument is a thermo shaker; where a single tube must be homogenised immediately, a vortex mixer is faster. A blood roller mixer is the right answer when the sample is in a closed tube, must stay homogeneous over time, and must not be damaged.
Model, product code and identification
The ROMIX70 is supplied as a single model. Quote and order with the COLO product code so the correct configuration is identified without ambiguity.
COLO product code: PRO4582 · Manufacturer code: RM100
Blood roller mixer, 6 rollers, 20–99 rpm, rolling and swinging, forward / reverse, maximum load 4 kg.
Technical specifications
| Product code | PRO4582 |
| Speed range | 20–99 rpm |
| Operation mode | Rolling & swinging |
| Swinging amplitude | 25 mm |
| Number of rollers | 6 |
| Roller length | 280 mm |
| Tubes and bottles accepted | 8–200 mm |
| Maximum load | 4 kg |
| Forward / reverse motion | Yes, programmable |
| Forward / reverse interval | 30 s – 99 min 59 s |
| Timer | 1 min – 99 h 59 min, or continuous |
| Display | Independent LED for speed and for time |
| Control | Digital, push-button |
| Motor | Brushless DC, maintenance-free |
| Power | 15 W |
| Supply voltage | AC 100–240 V, 50–60 Hz |
| Dimensions (W × D × H) | 480 × 250 × 100 mm |
| Net weight | 3.8 kg |
Operating functions
Speed and time
Speed and time have their own LED displays and their own buttons, so the operator reads both values at a glance without switching menus. Speed is adjustable from 20 to 99 rpm in single steps. The timer covers 1 minute to 99 hours 59 minutes for a defined incubation, or the instrument runs continuously when a sample has to stay in motion until it is collected.
Forward and reverse motion
The direction of rotation reverses on a programmable interval between 30 seconds and 99 minutes 59 seconds. Reversing prevents a sample from settling into a repeating pattern and improves mixing in viscous media and in long suspensions, where one direction alone would eventually stratify the contents.
Loading the deck
The deck is open, with six rollers 280 mm long. Tubes are laid across the rollers and removed without tools or adapters, which matters in a routine laboratory where the same instrument is loaded dozens of times a day. Tubes and bottles from 8 mm to 200 mm are accepted, up to a total load of 4 kg.
Build, motor and safe operation
Inside the ROMIX70 blood roller mixer the drive is a brushless DC motor: there are no brushes to wear, no scheduled service interval and no carbon dust near open samples. It also runs quietly, which is the practical difference between an instrument that can sit on a working bench and one that has to be moved to a back room.
The housing is coated steel with the control panel set to the left of the roller deck, clear of the loading area, so tubes are placed and removed without reaching over the keys. Power comes from a wide-range supply, AC 100–240 V at 50–60 Hz and 15 W, so the same unit works in every market COLO.Science supplies without a voltage selector. The instrument measures 480 × 250 × 100 mm and weighs 3.8 kg, small enough to be moved between benches by one person.
Standard delivery
- ROMIX70 blood roller mixer with six rollers mounted on the deck.
- Mains cable for the wide-range AC 100–240 V supply.
- Operating manual.
- Declaration of conformity and warranty documentation.
The delivered configuration for a specific order is the one confirmed in the COLO.Science quotation.
Catalogue, technical specification and international links
- ROMIX70 blood roller mixer — technical specification (PDF) — four pages, A4 landscape, with the full parameter table.
- Shakers & Mixers overview — thermo shakers, orbital shakers, incubators, rockers, vortex mixers and roller mixers.
- Shakers & Mixers catalogue — model comparison by speed, orbit, temperature range and capacity.
- Shakers and mixers on COLO.Science — our international site.
Applications and operational value
In haematology the ROMIX70 blood roller mixer sits between the phlebotomy tray and the analyser. Tubes that arrive in batches are placed on the deck and stay in motion until they are processed, which removes the two failure modes that a bench does not: sedimentation of the cellular fraction, and clot formation in a tube that waited too long. Because the mixer runs continuously, a queue of samples does not become a queue of re-draws.
In immunology and biochemistry the same slow rotation serves incubation. Antibody–antigen binding, immune precipitation and any reaction that needs contact between a liquid and a suspended solid benefit from continuous turning rather than intermittent shaking. The forward and reverse interval matters here: reversing the direction redistributes a sediment that one-directional rolling would compact against the tube wall.
In preparation work the deck takes viscous substances, liquid–solid suspensions and roller bottles. The 4 kg load limit and the 280 mm roller length are what decide throughput: the practical question is not the instrument’s speed but how many tubes fit on the deck in one run.
Selection guide
- Tube format and count. Measure the tube diameter and length and count how many are processed in one run; the 280 mm rollers and the 4 kg limit set the capacity.
- Duration. A defined incubation uses the timer, from 1 minute to 99 h 59 min; a sample queue uses continuous running.
- Direction. Viscous media and settling suspensions justify the programmable forward / reverse interval; plain blood mixing usually does not need it.
- Temperature. If the protocol prescribes a temperature, a roller mixer is the wrong instrument — choose a thermo shaker or shaking incubator instead.
- Speed of mixing. If a single tube must be homogenised in seconds, a vortex mixer does that job; the roller mixer is for sustained, gentle motion.
Configuration notice
This page is provided for orientation and product selection. It does not replace the binding specification, the delivered configuration, the validation protocol or the acceptance criteria confirmed in the official COLO.Science quotation, proforma invoice or order confirmation. Confirm the tube format, the load per run and any certification requirement for the specific order. Specifications may change without notice. B2B prices are quoted net, excluding VAT.
Sales and support for international customers
COLO Lab Experts
Polje ob Sotli 4, SI-3255 Buče, Slovenia
Phone: +386 70 713 437 · Email: sales@colo.si · Web: colo.si
We supply laboratories across Europe directly and through partners. B2B prices are quoted net, excluding VAT.