MBIN7 portable microbiological incubators are designed for compact incubation workflows where bench space, mobility and simple temperature control are important. The series is suitable for small laboratories, decentralized QC stations, teaching laboratories, field sample handling and temporary backup incubation capacity.
The MBIN7 series uses natural convection, four-side heating, PID intelligent temperature control and a PT100 sensor. The mirror stainless steel chamber, rounded inner corners, two shelves, observation window and LED door light support practical daily use and routine visual inspection without unnecessary door opening.
Key characteristics
- Models: MBIN9 and MBIN12.
- Chamber volumes: 9.2 L and 12.8 L.
- Temperature range: RT+5 to 65°C.
- Temperature resolution: 0.1°C.
- Temperature motion: ±0.5°C.
- Temperature uniformity: ±1.0°C.
- Temperature control: PID intelligent control.
- Sensor: PT100.
- Cycle mode: natural convection.
- Optional DC12V vehicle power supply.
Suitable for
- Routine microbiological incubation in small laboratories.
- Temporary backup incubation during peak load or service downtime.
- Sample transport workflows with optional vehicle power supply.
- Teaching laboratories and practical demonstrations.
- Small-batch QC checks and screening workflows.
- Satellite laboratories and decentralized quality-control stations.
MBIN7 SERIES — PORTABLE MICROBIOLOGICAL INCUBATORS
Portable microbiological incubator series for compact 9 L and 12 L incubation workflows
The MBIN7 portable microbiological incubator series is intended for laboratories that need compact incubation capacity, stable temperature control and easy movement between benches or work areas. MBIN9 provides a 9.2 L chamber for the smallest footprint, while MBIN12 provides 12.8 L capacity and higher internal chamber height for larger containers or increased sample load.
Natural convection supports stable incubation without forced airflow. Four-side heating helps improve internal temperature distribution, while PID control, PT100 sensing, timed operation and over-temperature alarm functions support routine laboratory incubation with simple operation.
For mobile or field-related workflows, MBIN7 incubators can be specified with optional DC12V vehicle power supply. Final electrical configuration, plug type, vehicle power option, accessories and documentation package should be confirmed in the official quotation.
MBIN7 portable incubator, model comparison and chamber details

MBIN7 portable microbiological incubators are compact chambers for routine incubation, small laboratory workflows and portable temperature-controlled use.

MBIN9 and MBIN12 provide two compact volume options for different sample loads, container heights and available bench space.

Detail views show the stainless steel chamber, portable handle, cabinet construction and connection area for practical portable use.
MBIN7 series — model variants and catalogue selection parameters
MBIN9
Volume: 9.2 L
Temperature range: RT+5 to 65°C
Resolution: 0.1°C
Temperature motion: ±0.5°C
Uniformity: ±1.0°C
Inner chamber: 230 × 200 × 200 mm
Exterior size: 310 × 276 × 298 mm
Power rating: 0.08 kW
Current rating: AC220V / 0.36 A
N.W. / G.W.: 8 / 10 kg
MBIN12
Volume: 12.8 L
Temperature range: RT+5 to 65°C
Resolution: 0.1°C
Temperature motion: ±0.5°C
Uniformity: ±1.0°C
Inner chamber: 230 × 200 × 280 mm
Exterior size: 310 × 276 × 378 mm
Power rating: 0.12 kW
Current rating: AC220V / 0.55 A
N.W. / G.W.: 12 / 14 kg
Model note: select MBIN9 for the smallest footprint and lighter transport. Select MBIN12 when higher internal height or larger sample volume is required. Specify if DC12V vehicle operation is needed.
TECHNICAL SPECIFICATIONS — MBIN7 PORTABLE MICROBIOLOGICAL INCUBATOR SERIES
| Product series | MBIN7 portable microbiological incubators |
| Model variants | MBIN9 / MBIN12 |
| Chamber volumes | 9.2 L / 12.8 L |
| Cycle mode | Natural convection |
| Heating concept | Four-side heating |
| Temperature range | RT+5 to 65°C |
| Temperature resolution | 0.1°C |
| Temperature motion | ±0.5°C |
| Temperature uniformity | ±1.0°C |
| Temperature control mode | PID intelligent control |
| Setting mode | Touch-button setting |
| Display mode | Measured temperature: LED upper row; set temperature: lower row |
| Timer | 0–9999 min, with timing wait function |
| Sensor | PT100 |
| Chamber material | Mirror stainless steel chamber with rounded inner corners |
| Insulation | Polyurethane insulation |
| Observation | Glass door window and LED door light |
| Safety functions | Over-temperature sound-light alarm, sensor-fault alarm, menu locking, internal parameter locking, power-off parameter memory |
| Shelves / load | 2 shelves; 5 kg load per rack; 35 mm shelf spacing |
| MBIN9 inner chamber | 230 × 200 × 200 mm |
| MBIN12 inner chamber | 230 × 200 × 280 mm |
| MBIN9 exterior size | 310 × 276 × 298 mm |
| MBIN12 exterior size | 310 × 276 × 378 mm |
| MBIN9 power / current | 0.08 kW; AC220V / 0.36 A |
| MBIN12 power / current | 0.12 kW; AC220V / 0.55 A |
| Optional accessory | Vehicular DC12V power supply |
Final incubation performance depends on correct installation, ambient temperature, chamber loading, container type, air circulation around samples, door-opening frequency, temperature setpoint and validation routine. Final model, electrical configuration, plug type, DC12V vehicle power option, accessories, certificates and documentation are confirmed in the official quotation.
STANDARD PACKAGING / STANDARD DELIVERY
Standard MBIN7 package
Included in standard packaging
- Selected MBIN7 portable microbiological incubator model.
- Two shelves.
- Power cable / electrical connection according to configuration.
- Instruction manual / user guide.
Optional configuration
- Vehicular DC12V power supply.
- Electrical plug configuration according to market.
- Additional documentation package according to quotation.
- Application-specific support for transport and field-use workflows.
Incubation functions and laboratory workflow
Routine incubation
RT+5 to 65°C temperature range supports common small-chamber incubation workflows in microbiology, QC and teaching laboratories.
Timed operation
The 0–9999 min timer with timing wait function supports routine fixed-time incubation and controlled workflow planning.
Observation without opening
The glass door window and LED door light support quick visual checks while reducing unnecessary door opening.
Portable use
The compact housing, top handle and optional DC12V vehicle supply support mobile use, controlled transport and temporary work areas.
OPTIONAL ACCESSORY AND CONFIGURATION
Optional DC12V vehicle power supply for controlled transport workflows
MBIN7 incubators can be configured with optional vehicular DC12V power supply when controlled sample transport or field collection workflows are required. This option should be specified before quotation together with the intended vehicle use, transport duration, required incubation temperature and electrical configuration.
DC12V vehicle operation
Useful when the incubator must support controlled sample handling during field collection, short transport or temporary mobile laboratory workflows.
Electrical configuration
Confirm AC supply, plug type, vehicle supply option and final electrical configuration before ordering.
Documentation package
For controlled laboratory workflows, define documentation, acceptance criteria and any internal verification requirements in the quotation stage.
Ordering note: confirm selected model, chamber volume, target incubation temperature, container height, sample load, transport requirement, DC12V vehicle operation and documentation package in the official quotation.
INCUBATOR CATALOGUE
Compare portable microbiological incubators and laboratory incubation equipment
Use the incubator catalogue to compare MBIN7 models with other laboratory incubators, drying ovens, environmental chambers and temperature-controlled laboratory equipment.
COLO.SCIENCE KNOWLEDGE AND SUPPORT
Selection support for compact incubation, sample load and portable workflows
COLO.Science supports complete incubation configurations: chamber volume selection, temperature setpoint review, sample/container height, shelf loading, transport workflow, optional DC12V vehicle supply and documentation requirements.
How to select the appropriate MBIN7 model
When selecting an MBIN7 portable microbiological incubator, first define the required chamber volume, sample load, container dimensions and required internal height. MBIN9 is suitable when the smallest footprint and lighter transport are important. MBIN12 is better when additional internal height or larger sample volume is required.
The second selection step is the workflow: routine bench incubation, teaching use, small-batch QC, backup capacity or controlled sample transport. If the incubator will be used in a vehicle or field workflow, specify the optional DC12V vehicle power requirement before quotation.
MBIN7 portable microbiological incubators for compact 9 L and 12 L laboratory incubation
MBIN7 portable microbiological incubators are intended for laboratories that need compact incubation capacity, easy movement and reliable routine temperature control. The series covers MBIN9 and MBIN12 models, with 9.2 L and 12.8 L chamber volumes, RT+5 to 65°C temperature range, natural convection, four-side heating, PID intelligent control and PT100 temperature sensing.
In practical use, incubation performance depends on ambient temperature, correct placement, chamber loading, container geometry, shelf arrangement, door-opening frequency, temperature setpoint and verification routine. The optional DC12V vehicle power supply can extend the use of MBIN7 incubators into controlled transport and field sample handling workflows.
Configuration notice
MBIN7 portable microbiological incubators may be supplied with different configurations depending on selected model, electrical supply, plug type, optional DC12V vehicle power supply, accessories and documentation requirements. This page is provided for orientation and product selection. It does not replace the binding specification, delivered configuration, accessory set or acceptance criteria confirmed in the official COLO.Science quotation, proforma invoice, order confirmation or manufacturer-approved technical offer. Specifications may change without notice.