CH1020 Light Transmittance Meter, VLT, UV, IR, SHGC


COLO.Science · Light Transmittance Meter

VLT · UV rejection · IR 940 nm / 1400 nm / full band · SHGC · TSER · 0.5 s · up to 47 mm

COLO.Science · Spectroscopy & Color · Light transmittance

CH1020 Light Transmittance Meter — VLT, IR rejection, SHGC and TSER

The CH1020 light transmittance meter (COLO product code PRO7935) is a compact meter for solar-control film and glazing: VLT, UV and IR rejection, SHGC and TSER. It measures VLT, UV rejection, IR rejection (940 nm, 1400 nm, full band), SHGC, TSER in about 0.5 s, for samples up to 47 mm thick.

Overview

Switch on — the meter calibrates itself — slide the glass or film into the slot and read the values on the 3.5″ colour screen. Weighing 515 g and powered over USB-C, it works in the laboratory, at incoming control and on site.

CH1020 light transmittance meter — compact meter with sample slot

Key characteristics

  • Light sources: UV, visible, infrared 940 nm, 1400 nm and full band
  • Silicon photodiode sensors; Visible 380–760 nm; infrared peaks 940 and 1400 nm; full-band infrared
  • Measured: VLT, UV rejection, IR rejection (940 nm, 1400 nm, full band), SHGC, TSER
  • Resolution 0.1 %; accuracy better than ±1.5 % (colourless uniform translucent sample)
  • Samples up to 47 mm thick; automatic calibration at switch-on
  • 3.5″ colour screen, USB; 5 V DC over USB-C; 203 × 120 × 29 mm, 515 g

Suitable for

  • Window film — tinted and solar-control film before and after fitting
  • Architectural and automotive glass
  • Transparent plastic sheets and covers
  • Incoming control of glass and film

What do VLT, UV and IR rejection mean?

Glass and window film are chosen by how much daylight they let through and how much ultraviolet and heat they keep out. VLT (visible light transmittance) is the share of daylight that passes, in %. UV rejection is the share of ultraviolet radiation blocked, IR rejection the share of infrared (heat) blocked — at 940 nm, at 1400 nm and over the full infrared band.

  • VLT — brightness through the glass; legal limits apply to vehicle glazing in many countries.
  • UV rejection — protection of interiors, goods and skin.
  • IR rejection — heat kept out; the main value for solar-control film.
  • SHGC / TSER — solar heat gain coefficient and total solar energy rejected, the summary values used in window-film specifications.

Transmittance meter or haze meter?

Both measure how light passes a transparent sample, but for different questions. The transmittance meter answers how much light, UV and heat pass glass or film; a haze meter answers how clear or milky a material looks.

Transmittance meter (CH1020) Haze meter (CH1100–CH1810)
Main values VLT, UV rejection, IR rejection (940 nm, 1400 nm, full band), SHGC, TSER Haze, total transmittance, clarity, colour
Typical user Window film, glass processing, automotive Plastics, film and packaging production, laboratories
Form Compact, 515 g, USB-C Benchtop, 0/d with Ø154 mm sphere

On the instrument

Clear readout

Clear readoutVLT and rejection values shown together on the 3.5″ screen.
Slot for flat samples

Slot for flat samplesGlass, film or sheet up to 47 mm thick slides into the gap.

Technical specifications

Measurement

Light sources UV, visible, infrared 940 nm, 1400 nm and full band
Sensor Silicon photodiodes
Wavelength range Visible 380–760 nm; infrared peaks 940 and 1400 nm; full-band infrared
Measured values VLT, UV rejection, IR rejection (940 nm, 1400 nm, full band), SHGC, TSER
Resolution 0.1 %
Accuracy better than ±1.5 % (colourless uniform translucent sample); better than ±1 % on factory standards
Measuring time approx. 0.5 s

Data and general

Sample thickness up to 47 mm
Calibration automatic at switch-on
Display 3.5″ TFT colour
Interface · power USB · 5 V DC, USB-C
Dimensions · weight 203 × 120 × 29 mm · 515 g
Operating environment 0–40 °C, 0–85 % RH non-condensing, up to 2000 m; storage −20–50 °C

Which model? — comparison

Both meters share the same compact body, 0.5 s measurement, 0.1 % resolution, ±1.5 % accuracy and samples up to 47 mm. They differ in the infrared values:

CH1010 CH1020
VLT, UV rejection ✓ ✓
IR rejection 940 nm ✓ ✓
IR rejection 1400 nm, full-band IR — ✓
SHGC, TSER — ✓
  • CH1010 — VLT, UV and 940 nm IR rejection: the quick check of tinted glass and film.
  • CH1020 — adds 1400 nm and full-band IR, SHGC and TSER for solar-control film and glazing.

Standard delivery

  • CH1020 light transmittance meter
  • Power adapter, data cable
  • User guide

Calibration check on request. The delivered configuration for a specific order is the one confirmed in the COLO.Science quotation.

Knowledge base

Haze, transmittance, clarity and the 0/d geometry are explained in the Haze Measurement Guide, colour values in the Colour Measurement Guide, and practical examples on COLO.Science, our knowledge base.

Selection guide

Configuration notice

This page is provided for orientation and product selection. The model and the values you report are confirmed with the official COLO.Science quotation.

Sales and support for international customers

COLO Lab ExpertsPolje ob Sotli 4, SI-3255 Buče, Slovenia
Phone: +386 70 713 437 · Email: sales@colo.si · Web: colo.si
We supply laboratories across Europe directly and through partners. B2B prices are quoted net, excluding VAT.

Checking glass or window film?

Send us the type of glass or film and the values you need — we propose the model and confirm it with the quotation.

SKU: PRO7935 Category:

Request a Quote