Two Shops
One Shipment

CENTA 1000g/0,01g Laboratory Precision Balance


COLO.Science · Precision Balance

CENTA1000 is a precision balance with 1000 g capacity, 0.01 g readability, Class II accuracy, RS232 interface, external calibration and 160 × 160 mm stainless-steel pan.

1000 g · 0.01 g · Class II · RS232 · 160 × 160 mm · PRO4329

COLO.Science — LABORATORY BALANCES / PRECISION WEIGHING — CENTA1000

CENTA1000 Precision Balance 1000 g / 0.01 g

CENTA1000 precision balance is an economical laboratory and industrial weighing instrument with 1000 g maximum capacity, 0.01 g readability, Class II accuracy class, external calibration, RS232 interface and a large 160 × 160 mm stainless-steel pan. It is suitable for routine laboratory weighing, research work, quality control, sample preparation, parts counting and percentage weighing.

Overview PDF Video Soon Quote

COLO.SCIENCE — LABORATORY PRECISION BALANCES

Precision balance with backlit LCD, RS232 and external calibration

The CENTA1000 precision balance is designed for laboratories, production areas and quality-control workflows that require stable weighing up to 1000 g with 0.01 g readability. A high-precision load cell, external calibration and backlit LCD display support practical daily weighing and routine checking tasks.

The 160 × 160 mm stainless-steel pan provides a practical weighing surface for samples, vessels and containers, while RS232 communication and optional software allow the balance to be integrated into printer or PC data-collection workflows when required.

Key features

  • CENTA1000 precision balance with 1000 g capacity and 0.01 g readability.
  • Class II accuracy class for routine laboratory and QC weighing.
  • High-precision load cell for sharp and stable weighing performance.
  • 160 × 160 mm stainless-steel pan for samples, vessels and containers.
  • External calibration with external linear calibration support.
  • Backlit LCD display for improved result visibility.
  • RS232 interface for optional printer or PC communication workflows.

Suitable for

  • Routine laboratory sample weighing.
  • Quality control and check weighing.
  • Research and educational laboratories.
  • Formulation and reagent preparation.
  • Parts counting and inventory support.
  • Percentage weighing and production inspection tasks.

TECHNICAL SPECIFICATIONS — CENTA1000 PRECISION BALANCE

Model CENTA1000
SKU PRO4329
Product type Precision balance / industrial balance
Maximum capacity 1000 g
Readability / division 0.01 g
Accuracy class Class II
Minimum weighing 200 mg
Repeatability ±20 mg
Accuracy ±10 mg
Linearity ±20 mg
Stabilization time ≤ 1.5 s
Measuring cell High-precision load cell
Calibration External calibration
Calibration method External linear calibration
Pan dimensions 160 × 160 mm, stainless steel
Display High-resolution backlit LCD
Interface RS232
Functions Check weighing, parts counting, percentage weighing
Operating temperature 15–40 °C, fluctuation < 5 °C/h
Relative humidity 40–80% RH
Power supply AC 110–240 V, 50/60 Hz; DC 5 V / 2 A
Battery operation Optional rechargeable accumulator
Standard accessories Universal power adapter and instruction manual
Optional accessories Thermal printer, control weight, calibration certificate, software, rechargeable accumulator
Dimensions / weight 225 × 220 × 80 mm · net/gross weight 1.2 / 1.5 kg

Source note: values are taken from the CENTA family technical specification. The source lists an accuracy value of ±10 mg and repeatability/linearity values of ±20 mg; final acceptance criteria, delivered configuration and calibration-documentation scope must be confirmed in the official quotation.

Calibration, power supply and data output

External calibration

CENTA1000 uses external calibration and external linear calibration support. For controlled laboratory work, the required nominal weight, weight class and certificate type should be defined according to the local SOP and required documentation level.

Optional accumulator

The balance is supplied with a universal power adapter, while an optional rechargeable accumulator can support operation independent of the power supply when mobile or flexible bench use is required.

RS232, printer and software

The RS232 interface allows optional connection to a thermal printer or PC workflow. Optional software can support data collection, balance communication and measurement-process control.

OPTIONAL ACCESSORY — CALIBRATION WEIGHTS

Optional OIML M1 calibration and control weights

For routine verification and external calibration of the CENTA1000 precision balance, COLO.Science can offer suitable OIML M1 calibration or control weights as optional accessories. The required nominal mass, accuracy class and certificate type should be confirmed according to the laboratory procedure and traceability requirements.

For the CENTA1000 model, the technical selection should consider sample weight, tare container mass, required headroom and the calibration routine. Available M1 options include individual weights and weight sets; the final accessory package should be defined in the quotation.

View Calibration Weights Ask for Weight

COLO.SCIENCE VIDEO

CENTA1000 video presentation is in preparation

The video will present operation of the CENTA1000 precision balance, external calibration, backlit LCD display, RS232 communication, optional calibration weights and practical laboratory weighing workflows.

Video Soon

COLO.SCIENCE KNOWLEDGE

Learn more about laboratory weighing equipment

Explore COLO.Science resources covering laboratory balances, precision weighing, calibration planning, sample preparation and routine quality-control workflows.

Read on COLO.Science →

Applications and laboratory value

Routine laboratory weighing

CENTA1000 precision balance is suitable for daily weighing of samples, reagents and vessels where 1000 g capacity and 0.01 g readability are required.

Quality control

The balance supports check weighing, batch checks, incoming inspection and repeated control tasks in laboratory and production QC environments.

Research and education

Backlit LCD visibility, fast stabilization and clear routine operation make CENTA1000 practical for research benches, training rooms and teaching laboratories.

Counting and percentage work

Parts counting and percentage weighing support practical production, inventory, formulation and inspection workflows when the weighing method is suitable for the sample.

How to choose the correct CENTA1000 configuration

When selecting a CENTA1000 precision balance, confirm the required weighing range, tare load, sample container, calibration procedure, need for printed records and whether PC data collection is required. Laboratories should also define routine-check frequency, acceptance limits and required traceability documentation.

COLO.Science can support the selection of the balance, optional accumulator, RS232 printer or software, OIML M1 calibration weights, control weights and calibration certificate so that the final configuration matches the laboratory method and procurement requirements.

CENTA1000 precision balance for 1000 g laboratory weighing

The CENTA1000 precision balance is useful when a laboratory needs a compact and economical weighing instrument with 1000 g capacity, 0.01 g readability, external calibration, RS232 communication and a large stainless-steel pan. It is a practical choice for routine weighing, sample preparation, QC inspection, formulation work and educational laboratory tasks.

In daily use, weighing quality depends on correct placement, stable environmental conditions, suitable calibration routine, regular control checks and proper handling of samples and containers. CENTA1000 provides the precision balance platform, while COLO.Science can help define the correct accessories and documentation for the final application.

Configuration notice

Precision balances may be delivered with different accessories, calibration weights, certificates, accumulators, printers, adapters or software options depending on the selected configuration. The official quotation defines the final scope of supply. Website content is provided for general product presentation and may not represent the exact delivered configuration. Specifications may change without notice.

Need a CENTA1000 precision balance configuration?

Contact COLO.Science for product selection, calibration-weight planning, optional accumulator, RS232 printer, software, technical documentation and quotation support for the CENTA1000 precision balance.

Request a Quote PDF Spec Video Soon

 

SKU: PRO4329 Category:
Balance Types

Precision Balance

Display Type

LCD

Balance Capacity

Balance Resolution

Type CENTA2000 CENTA3000 CENTA5000
Maximum Capacity (g) 2000g 3000g 5000g
Accuracy Class II
Division  (g) 0,01g
Min weighing (g) 200mg
Repeatability (g) ±20mg
Linear (g) ±20mg
Stabilization time ≤1,5sec
Operating temperature 15℃~40℃, fluctuation range<5℃/h
Operating Relative humidity (RH) 40%~80%
Power supply AC110-240V 50/60Hz DC5V-2A
Pan Size 160mm*160mm
Calibration External
Display LCD
Interface RS232
System Check Weighing, Parts counting, percentage weighing
Included Accessories By Our Service Certificated Calibration Weight (Optional),  Universal power adapter, Instruction Manual,
Dimension(L*W*H) 225mm* 220mm*80mm
Net weight/Gross weight 1,2/1,5
Optional Thermal printer, Control weight, Certificate of Calibration, Software,

You may also like…

Request a Quote