Two Shops
One Shipment

LACEVAC7 Vacuum Centrifugal Concentrator, Built-in or External Pump, RT+5 °C to 80 °C


COLO.Science · Vacuum Centrifugal Concentrator

RT+5–80 °C · 300–2000 rpm · built-in pump · external pump version · 5 rotors · cold trap option

COLO.Science · Concentration & Evaporation · Vacuum centrifugal concentrators

LACEVAC7 vacuum centrifugal concentrator — built-in pump or external vacuum pump, RT+5 °C to 80 °C

The LACEVAC7 vacuum centrifugal concentrator removes solvent from many small samples at once: vacuum lowers the boiling point, gentle heat from RT+5 °C to 80 °C drives the evaporation, and rotation at 300 to 2000 rpm keeps the liquid at the bottom of the tube. It is offered in two versions — with its built-in pump for water and volatile solvents, or with an external vacuum pump for a deeper vacuum. Product code PRO7219.

Vacuum, heat and rotation in one chamber

Small volumes are easy to lose: under vacuum they bump, splash into the neighbouring tube, or dry onto the wall. In the LACEVAC7 vacuum centrifugal concentrator centrifugal force holds every sample down while it boils, so the dry residue collects at the bottom of its own tube, ready to be dissolved again.

LACEVAC7 vacuum centrifugal concentrator with open lid, rotor and touch screen

Key characteristics

  • RT+5 °C to 80 °C, accuracy ±1 °C.
  • 300 to 2000 rpm, adjustable.
  • Timer 1 min to 99 h, from start or from set temperature.
  • Built-in pump, chemically resistant, final vacuum −92 kPa (about 90 mbar absolute).
  • External pump version for a deeper vacuum.
  • 7-inch touch screen; heating, vacuum and rotation switched separately.
  • Stainless steel chamber, transparent lid, magnetic drive.
  • 5 rotors — 1.5 mL to 100 mL tubes and 96-well microplates.

Suitable for

  • DNA and RNA — drying of precipitates and concentration of eluates.
  • Proteins and peptides — enzymes, hydrolysates and fractions.
  • HPLC and chromatography — recovery of collected fractions.
  • Extracts in water, alcohols and acetonitrile, many tubes at once.
  • Two 96-well microplates in one run.

Why vacuum lowers the temperature you need

A liquid boils when its vapour pressure reaches the pressure around it. At about 90 mbar, the vacuum of the built-in pump, water boils at about 45 °C instead of 100 °C, and ethanol, methanol and acetonitrile below 30 °C. The LACEVAC7 vacuum centrifugal concentrator therefore dries samples at temperatures that proteins and nucleic acids tolerate.

Boiling points of water, ethanol, acetonitrile and methanol at atmospheric pressure and at 90 mbar

Solvents that still boil above 80 °C at this pressure, such as DMSO or DMF, need a deeper vacuum — that is what the version with an external vacuum pump is for. The values in the chart are calculated and rounded.

Two versions, product code and rotors

The LACEVAC7 vacuum centrifugal concentrator is one instrument in two versions. Rotors and the cold trap are chosen for the application and ordered separately. Quote and order with the COLO product code.

LACEVAC7 · built-in pumpCOLO product code: PRO7219
ready to run · about 90 mbar · water and volatile solvents
LACEVAC7 · external vacuum pumpCOLO product code: PRO7219 + pump
deeper vacuum · pump stated in the quotation
Five rotors for the LACEVAC7 vacuum centrifugal concentrator

Rotors

No. 1 66 × 1.5 mL
No. 2 24 × 1.5 mL + 24 × 5 mL
No. 3 12 × 10 mL
No. 4 4 × 50 mL or 4 × 100 mL
No. 5 2 × 96-well microplate

The instrument is supplied without a rotor. Rotor product codes are stated in the quotation.

Technical specifications

Operation and vacuum

Speed 300 to 2000 rpm, adjustable
Temperature setting range RT+5 °C to 80 °C
Temperature accuracy ±1 °C
Time range 1 min to 99 h
Display 7-inch LCD touch screen
Vacuum pump built-in, chemically resistant, 2 L/min
Final vacuum, built-in pump −92 kPa (about 90 mbar abs.)
External vacuum pump optional version, data in quotation

Build and general data

Chamber stainless steel, corrosion-resistant
Lid transparent
Drive magnetic, sealed chamber
Rotors 5 types, aluminium
Noise ≤ 65 dB(A)
Supply AC 220 V, 50 Hz
Dimensions (L × W × H) 580 × 360 × 330 mm
Net weight 44 kg

How a run works

Rotor and load

Fit the rotor, tighten the hold-down nut, place the tubes symmetrically and close the lid until it locks.

Run

Set temperature, speed and time on the touch screen and start. The LACEVAC7 vacuum centrifugal concentrator starts the rotor first and the pump after a delay, so the samples settle before the pressure falls. Parameters can be changed during the run.

End of run

When the time is over the instrument stops, vents and releases the lid — or holds the vacuum until you vent it yourself.

Chamber, vacuum path and cold trap

Vapour leaves the heated chamber of the LACEVAC7 vacuum centrifugal concentrator towards the pump. A cold trap at −50 °C between chamber and pump condenses it first; this protects the pump and speeds up drying, and is recommended with organic solvents.

Vacuum path of the LACEVAC7 vacuum centrifugal concentrator: chamber, cold trap and vacuum pump

How the cold trap works

Vapour from the chamber enters the trap through the centre tube and meets a wall held at −50 °C, where it freezes. Only gas that does not condense goes on to the pump. The trap therefore protects the pump from solvent, and because vapour is removed all the time, the pressure in the chamber stays low and drying is faster.

How the cold trap of the LACEVAC7 vacuum centrifugal concentrator works: vapour freezes on the cold wall

Switch the trap on first and start the run when it is cold. When ice has built up on the wall, defrost the trap and drain it.

Stainless steel chamber of the LACEVAC7 vacuum centrifugal concentrator with a rotor fitted
LACEVAC7 vacuum centrifugal concentrator with the optional cold trap

The chamber is stainless steel with a silicone seal, the lid is transparent so the run can be watched, and the magnetic drive needs no shaft seal. Rotor and chamber wall are hot after a run.

Standard delivery

  • LACEVAC7 vacuum centrifugal concentrator with built-in pump.
  • Mains cable and wrench for the rotor nut.
  • Operating manual.
  • Declaration of conformity and warranty documentation.

Rotors, cold trap and external vacuum pump are ordered separately. Tubes and samples are not part of the instrument. The delivered configuration for a specific order is the one confirmed in the COLO.Science quotation.

Compare the LACEVAC vacuum centrifugal concentrators

Four instruments cover the range from the compact unit for 1.5 mL tubes to programmable vacuum for demanding methods. The LACEVAC7 vacuum centrifugal concentrator is the highlighted column.

Model LACEVAC-1C
compact · external pump
LACEVAC4
programmable · external pump
LACEVAC6
all-in-one · built-in pump
LACEVAC7
touch screen · without or with built-in pump
Vacuum pump external; without or with pump external; without or with pump built-in, 33 L/min without pump or built-in, 2 L/min; stronger external pump as option
Vacuum 5 mbar with pump 5 mbar with pump ≤ 13 mbar built-in pump: −80 to −89 kPa in work, −92 kPa final (about 90 mbar);
optional external pump: 5 mbar
Vacuum display / control analogue gauge; on/off digital; set value 0.1 to 100 mbar digital gauge; on/off digital value on the touch screen; on/off
Speed 1800 rpm, fixed 800 to 2000 rpm 800 to 2000 rpm 300 to 2000 rpm
Centrifugal force 380 × g 530 × g 530 × g —
Temperature RT+5 °C to 70 °C RT+5 °C to 100 °C RT+5 °C to 100 °C RT+5 °C to 80 °C
Operation one button, quick temperature keys LCD, two-step time and temperature LCD, two-step time and temperature, 30 programs 7-inch touch screen
Rotor in delivery 66 × 1.5 mL 90 × 1.5 mL 90 × 1.5 mL none; chosen with the order
Largest tube 50 mL 100 mL 50 mL 100 mL
Microplates — 2 × 96-well 2 × 96-well 2 × 96-well
Dimensions (L × W × H) 350 × 280 × 290 mm 481 × 370 × 294 mm 608 × 370 × 348 mm 580 × 360 × 330 mm
Weight 18 kg 28.5 kg 38 kg 44 kg
Best for small laboratories, 1.5 mL tubes, limited space methods that need a set vacuum; high-boiling solvents one instrument on the bench, no separate pump water and volatile solvents, large tubes, plates

Options for every model

Vacuum pump VACUU-CDT30 · PRO3633Diaphragm pump with two PTFE heads, oil-free and maintenance-free. 30 L/min, final vacuum 5 mbar, 140 W, 10 kg. For models without a pump, and as a stronger pump for models with a built-in one.
Cold trap −50 °C, 2 LStands between the concentrator and the pump, freezes the solvent vapour and protects the pump. Recommended with organic solvents.

Knowledge base

Sample concentration and evaporation on COLO.Science — our knowledge base.

Selection guide

  • Solvent. Water and volatile solvents run on the built-in pump; high-boiling solvents need the external pump version.
  • Tubes. Type and number per run decide the rotor.
  • Temperature. Within RT+5 °C to 80 °C and safe for the sample.
  • Cold trap. Recommended with organic solvents and with an external pump.
  • Open tubes and nitrogen instead? See the SACO nitrogen sample concentrators.
  • Place of use. The LACEVAC7 vacuum centrifugal concentrator needs 580 × 360 mm on a stable, level bench and weighs 44 kg.

Configuration notice

This page is provided for orientation and product selection. It does not replace the binding specification, the delivered configuration, the validation protocol or the acceptance criteria confirmed in the official COLO.Science quotation, proforma invoice or order confirmation. Confirm the version, the rotors and the mains voltage version of the LACEVAC7 vacuum centrifugal concentrator for the specific order. B2B prices are quoted net, excluding VAT.

Sales and support for international customers

COLO Lab ExpertsPolje ob Sotli 4, SI-3255 Buče, Slovenia
Phone: +386 70 713 437 · Email: sales@colo.si · Web: colo.si
We supply laboratories across Europe directly and through partners. B2B prices are quoted net, excluding VAT.

With or without an external pump on your LACEVAC7 vacuum centrifugal concentrator?

Send the solvent, the tube type, the volume and the number of samples per run. COLO.Science will confirm the version, the rotors and the delivery time.

SKU: PRO7219 Category: