VIKING-TU500P Portable Turbidity Meter

VIKING-TU500P measures turbidity of drinking water, process water and wastewater by the nephelometric (or ratio) method with a 860 nm LED (ISO 7027): 0–500 NTU, ±2 % of reading + 0.02 NTU, zero and 1–4-point Formazin calibration, 1000-result GLP memory; IP65 housing for field use.

Portable Turbidity Meter0–500 NTU±2 % + 0.02 NTU860 nm LEDISO 7027IP65NTU / FNU / EBC1–4 pts

Overview

Applications

  • Drinking water: turbidity control after filtration and disinfection.
  • Wastewater: influent, effluent and clarifier monitoring.
  • Industry: process water, beverages, pharma and chemicals.
  • Environment: surface water and field sampling.

Why VIKING-TU500P

  • Accuracy: ±2 % of reading + 0.02 NTU
  • Calibration: Zero + 1–4 points with Formazin standards
  • Light source: 860 nm LED (ISO 7027)
  • Data memory: 1000 results, GLP (user ID, date, time)

Technical specifications

Model VIKING-TU500P
SKU PRO7161
Light source 860 nm LED (ISO 7027)
Measuring principle Nephelometric or ratio
Range (auto) 0.00–9.99 / 10.0–99.9 / 100–500 NTU
Resolution 0.01 / 0.1 / 1 NTU
Accuracy ±2 % of reading + 0.02 NTU
Repeatability ≤0.5 %
Stability ±0.5 % FS / 30 min
Units NTU, FNU, EBC
Reading modes Continuous, average and auto reading
Calibration Zero + 1–4 points with Formazin standards
Data memory 1000 results, GLP (user ID, date, time)
Data output RS-232 (printer)
Display 3.5″ LCD
Power supply Rechargeable Li battery; adapter 100–240 V AC / 5 V DC 2 A
Protection IP65 · Auto power-off
Dimensions 90 × 250 × 90 mm
Weight approx. 0.8 kg

ACCESSORIES AND CONSUMABLES

Accessories for the VIKING-TU500P

The VIKING-TU500P is delivered with 5 turbidity vials, carrying case, power adapter. Calibration standards are ordered separately to match the measuring range; spare vials and silicone oil keep the readings reliable.

VIKING-TU500P portable turbidity meter

PRO7162

Turbidity vials, 5 pcs

Optical glass sample vials with screw caps; keep them clean and scratch-free, mark the orientation.

Standard delivery

Carrying case —

—

Carrying case

Hard case for the meter, vials and standards for field work.

Standard delivery

Consumables on request

  • PRO7165 — Turbidity standards 20/200/500 NTU
  • Silicone oil and lint-free cloth
  • PRO7162 — Turbidity vials, 5 pcs
  • RS-232 printer
  • PRO7163 — Turbidity standards 20/200/500/1000/2000 NTU

Standards, vials and consumables on request. Full catalogue: Electrochemistry catalogue →

Selection guidance

VIKING-TU500P is chosen for economical field checks up to 500 NTU. COLO.Science helps you choose standards and vials.

Configuration checklist

  • Range: low turbidity (drinking water) or up to 500 NTU (wastewater).
  • Standard: ISO 7027 (LED) or US EPA 180.1 (tungsten lamp).
  • Place of use: laboratory bench or field (IP65 portable).
  • Calibration: weekly in routine work or before critical tests, from the lowest to the highest standard, then verification.

Where the VIKING-TU500P portable turbidity meter fits

The VIKING-TU500P portable turbidity meter is intended for routine turbidity measurement in drinking water, process water and wastewater laboratories. With a measuring range of 0–500 NTU and measurement according to ISO 7027, the VIKING-TU500P portable turbidity meter covers both low-turbidity samples such as treated drinking water and more heavily loaded samples from process control. Calibration is carried out with formazin or equivalent polymer standards, and results are shown in NTU. COLO.Science supports the instrument with standards, cuvettes, installation advice and service, so that it stays within specification throughout its working life.

Calibration and care of the VIKING-TU500P portable turbidity meter

Reliable turbidity results depend on clean cuvettes and regular verification. Before each series, wipe the cuvette with a lint-free cloth, check that it is free of scratches and air bubbles, and align it in the measuring chamber. Verify the VIKING-TU500P portable turbidity meter against a calibration standard at the interval required by your quality procedure, and recalibrate when the reading falls outside the permitted tolerance. Store standards as specified by their manufacturer and replace them after the expiry date. COLO.Science can supply verification standards and replacement cuvettes for the VIKING-TU500P portable turbidity meter and advise on a calibration schedule.

Sales and support for international customers

COLO Lab ExpertsPolje ob Sotli 4, SI-3255 Buče, Slovenia
Phone: +386 70 713 437 · Email: sales@colo.si · Web: colo.si
We supply laboratories across Europe directly and through partners. B2B prices are quoted net, excluding VAT.

Need help choosing the right VIKING-TU500P portable turbidity meter configuration?

Tell us the sample type, the expected turbidity and the standard you report by. COLO.Science will confirm the VIKING-TU500P configuration, standards and vials.

Request a Quote