COLO.Science — WATER QUALITY / ELECTROCHEMISTRY — VIKING ISE600
Viking ISE600 Laboratory pH Ion Meter | COLO.Science
Viking ISE600 Laboratory pH / Ion Meter is a professional benchtop electrochemistry analyzer for high-accuracy measurement of pH, ion-selective electrodes / ISE, ORP, mV, pX and temperature. Designed for water laboratories, utilities, research institutions and method development, the ISE600 combines a 7.0″ touchscreen, GLP-compliant data management, audit trails, calibration reminders, user / electrode / method management and USB & RS-232 connectivity in one laboratory platform.
| Overview | PDF Tech Spec | HTML Tech Spec | Video coming | Request quote |
COLO.SCIENCE — LABORATORY PH / ION MEASUREMENT PLATFORM
Benchtop pH / ion meter for pH, ISE, ORP, mV, pX and temperature
The Viking ISE600 Laboratory pH / Ion Meter is built for laboratories that need traceable, high-resolution electrochemical measurement. It supports pH, ion-selective electrode measurement, oxidation-reduction potential, mV, pX and temperature in a professional benchtop format.
The 7.0″ touchscreen simplifies routine work, calibration setup, data review and method handling. GLP-compliant data management, audit trails, calibration reminders, internal storage and USB / RS-232 interfaces make Viking ISE600 suitable for water-quality laboratories, utilities, contract testing, research and industrial quality-control workflows.
Key benefits
- Laboratory pH / ion meter for pH, ISE, ORP, mV, pX and temperature.
- 7.0″ touchscreen for intuitive measurement, calibration and data workflow.
- High-resolution pH measurement from −2.000 to 20.000 pH with ±0.002 pH accuracy.
- ISE range 1.00E−9 to 9.99E9 with 4 significant digits and ±0.3% accuracy.
- 1–6 point ISE calibration with direct reading, standard addition, sample addition and Gran plot.
- GLP-compliant data management with user, electrode, method and data tools.
- USB & RS-232 interfaces for PC, printer or LIMS connection.
Suitable for
- Drinking-water and wastewater laboratories.
- Industrial and environmental monitoring laboratories.
- Water-utility laboratories and contract testing services.
- Fertilizer and food industry quality-control workflows.
- Educational, chemical and environmental research institutions.
- Method development with ion-selective electrodes and pX measurement.
- Laboratories that require GLP documentation, audit trails and data traceability.
Viking ISE600 Laboratory pH Ion Meter | COLO.Science
TECHNICAL SPECIFICATIONS — VIKING ISE600 LABORATORY PH / ION METER
| Model | Viking ISE600 / VIKING-I600 |
| Product number | PRO4949 |
| Main unit SKU | PRO6086 |
| Product type | Benchtop laboratory pH / ion meter |
| Measured parameters | pH, ISE, ORP, mV, pX and temperature |
| Display | 7.0″ touchscreen LCD |
| pH range / resolution / accuracy | −2.000 to 20.000 pH · 0.1 / 0.01 / 0.001 · ±0.002 pH |
| ORP / mV range | −2000 to +2000 mV · 0.1 / 0.01 mV · ±0.03% FS |
| ISE range | 1.00E−9 to 9.99E9 · 4 significant digits · ±0.3% |
| ISE calibration | 1–6 point ISE calibration |
| ISE methods | Direct reading, standard addition, sample addition and Gran plot |
| ISE units | µg/L, mg/L, g/L, mmol/L and pX |
| pX range / resolution / accuracy | −2.000 to 20.000 pX · 0.1 / 0.01 / 0.001 · ±0.002 pX |
| Temperature range / accuracy | −5 to 130 °C · 0.1 °C · ±0.1 °C |
| Data storage | Up to 1000 data sets per parameter in instrument memory |
| Data management | GLP-compliant data management, user / electrode / method / data management, audit trails and calibration reminders |
| Interfaces | USB & RS-232 for PC, printer or LIMS connection |
| Optional DO module | Barometric and manual salinity compensation available when optional DO module is installed |
Final measurement performance depends on electrode type, electrode condition, calibration standards, sample matrix, temperature control, selected method and laboratory procedure. Electrodes, ISE probes, calibration solutions, DO module and data accessories should be confirmed in the official quotation.
ISE calibration, GLP workflow and data connectivity
High-accuracy pH measurement
Viking ISE600 supports high-resolution pH measurement from −2.000 to 20.000 pH with resolution down to 0.001 pH and accuracy of ±0.002 pH, making it suitable for demanding laboratory methods.
ISE methods and ion units
ISE workflows support 1–6 point calibration, direct reading, standard addition, sample addition and Gran plot methods. Available concentration units include µg/L, mg/L, g/L, mmol/L and pX.
GLP-compliant management
User, electrode, method and data management tools, combined with audit trails and calibration reminders, support controlled operation in laboratories that require traceability and method discipline.
USB, RS-232 and LIMS workflow
USB and RS-232 interfaces allow connection to a PC, printer or LIMS workflow, while internal memory stores up to 1000 data sets per parameter for routine documentation.

COLO.SCIENCE STANDARD DELIVERY
Benchtop pH / ion meter with measurement module and laboratory accessories
Standard delivery can include the Viking ISE600 main unit, pH / ISE measurement module, electrode holder, power adapter, starter set of calibration solutions, USB cable for PC / printer connection, multilingual user manual and quick-start guide. The final configuration should always be confirmed in the official COLO.Science quotation.
| Open HTML Tech Spec | Request quote |
COLO.SCIENCE VIDEO
Video presentation for Viking ISE600 is in preparation
The video will present the 7.0″ touchscreen workflow, pH calibration, ISE method setup, standard addition, sample addition, Gran plot workflow, data storage, USB / RS-232 connectivity and laboratory use of the Viking ISE600 pH / ion meter.
COLO.SCIENCE KNOWLEDGE
Learn more about water-quality and ion-selective measurements
Explore COLO.Science resources about pH measurement, ion-selective electrodes, dissolved oxygen, ORP, calibration standards, electrode handling and practical water-quality applications.
Applications and laboratory value
Water-quality laboratories
Viking ISE600 supports pH, ORP, mV, pX, ISE and temperature workflows for drinking-water, wastewater and environmental laboratory methods.
Ion-selective analysis
1–6 point ISE calibration, multiple ion units and Gran plot support make the instrument suitable for ion-selective method development and routine ion measurement.
Industrial and food QC
The ISE600 can support fertilizer, food, process-water and industrial QC workflows where pH, ion concentration and traceable data records are required.
Research and education
A touchscreen interface, method management and multiple electrochemical measurement modes make the system practical for chemical, environmental and educational laboratories.
How to select the correct Viking ISE600 configuration
When selecting the Viking ISE600 Laboratory pH / Ion Meter, the final configuration should be matched to the target parameters, electrode types, expected concentration range, required ISE method, calibration standards, sample matrix and reporting workflow. Direct reading, standard addition, sample addition and Gran plot methods can require different standards, sample preparation and documentation procedures.
COLO.Science can help confirm the suitable pH electrode, ORP electrode, ion-selective electrode, calibration solutions, electrode holder, optional DO module, USB / RS-232 connection, printer or LIMS workflow and accessories so the delivered system matches the laboratory method and official quotation.
Configuration notice
Benchtop pH / ion meters can be delivered with different electrodes, ISE probes, calibration solutions, DO module options, data cables, printer / LIMS accessories and documentation packages depending on the selected application and quotation. The official quotation defines the final scope of supply. This webpage is provided for general product presentation and may not represent the exact delivered configuration. Specifications may change without prior notice.

