COLO.Science — WATER QUALITY / ELECTROCHEMISTRY — VIKING-ISE510
VIKING-ISE510 pH Ion Meter | Portable pH/ISE Meter | COLO.Science
VIKING-ISE510 portable pH/ion meter is a field-ready electrochemistry instrument for
pH, ion-selective electrode measurement, pX, ORP/mV and temperature. With a
4.3″ color touchscreen, ±0.002 pH accuracy, ±0.3% ISE accuracy,
up to 8-point pH calibration, up to 6-point ISE calibration, GLP data storage,
USB 2.0 communication and IP65 waterproof housing, VIKING-ISE510 is suitable for laboratory, industrial and field water-quality workflows.
| Overview | HTML Spec | Quote |
COLO.SCIENCE — PORTABLE WATER QUALITY / ELECTROCHEMISTRY METERS
Portable pH/ion meter for pH, ISE, pX, ORP/mV and temperature workflows
The VIKING-ISE510 portable pH/ion meter is designed for professionals who need accurate ion-selective, pH and ORP/mV measurement in the laboratory, production plant or field. The 4.3″ color touchscreen provides clear access to calibration, electrode management, measurement methods and GLP-oriented data handling.
VIKING-ISE510 supports direct ion measurement, standard addition, sample addition and GRAN methods. It is especially useful for water quality laboratories, wastewater control, environmental monitoring, fertilizer and food quality control, chemical research and education.
Key features
- Portable pH/ion meter for pH, ISE concentration, pX, ORP/mV and temperature.
- 4.3″ color touchscreen with smart operating system and simple method navigation.
- pH range −2.000 to 20.000 with selectable 0.1 / 0.01 / 0.001 pH resolution.
- High pH accuracy ±0.002 pH for precise field and laboratory pH measurement.
- ISE range 1.000e⁻⁹ to 9.999e⁺⁹ with mol/L, mmol/L, g/L, mg/L, μg/L, ppm and ppb units.
- IP65 waterproof housing, rechargeable battery, USB 2.0 output and GLP memory.
Suitable for
- Drinking-water, wastewater and surface-water analysis.
- Environmental monitoring and industrial process water checks.
- Fertilizer, food, beverage and agricultural quality control.
- Ion-selective electrode measurement in laboratory and field applications.
- Chemical research, education and method development.
- Routine QA/QC workflows requiring calibration tracking and data traceability.
TECHNICAL SPECIFICATIONS — VIKING-ISE510 PORTABLE PH/ION METER
| Model | VIKING-ISE510 |
| SKU | PRO4754 |
| Product type | Portable pH / ion-selective electrode / ORP / mV meter with touchscreen |
| Measured parameters | pH / ISE concentration / pX / ORP / mV / Temperature |
| Display | 4.3″ color touchscreen |
| pH range | −2.000 to 20.000 pH |
| pH resolution / accuracy | 0.1 / 0.01 / 0.001 pH · ±0.002 pH |
| pH calibration | Up to 8 points; USA, NIST, MERK, JIS, GB, DIN and user-defined buffers |
| mV / ORP range | −2000.00 to 2000.00 mV |
| mV resolution / accuracy | 0.1 / 0.01 mV · ±0.1 mV or ±0.03%, whichever is greater |
| pX range / accuracy | −2.000 to 20.000 pX · ±0.002 pX |
| ISE range | 1.000e⁻⁹ to 9.999e⁺⁹ |
| ISE units | mol/L, mmol/L, g/L, mg/L, μg/L, ppm, ppb |
| ISE resolution / accuracy | Up to 4 significant digits · ±0.3% |
| ISE calibration / methods | Up to 6 points · Direct Reading, Standard Addition, Sample Addition, GRAN |
| Built-in ions | F⁻, Cl⁻, Br⁻, I⁻, NO₃⁻, BF₄⁻, NH₄⁺, K⁺, Na⁺, Ca²⁺, Cu²⁺, Pb²⁺, Ag⁺ and others |
| Temperature range | −10 to 135 °C / 14 to 275 °F |
| Temperature resolution / accuracy | 0.1 °C / °F · ±0.1 °C |
| Temperature compensation | ATC / MTC |
| Reading modes | Auto-read Fast / Medium / Slow, timed-read and continuous-read |
| Data storage | 1000 groups per parameter, GLP-compliant |
| Communication | USB 2.0 flash drive / PC / scanner |
| Inputs | pH electrode BNC Q9; temperature probe 4-pin aviation connector |
| Protection / clock | IP65; date and time supported |
| Power supply | Rechargeable Li-ion battery; AC adapter 100–240 V / DC 5 V |
| Dimensions / weight | 90 × 255 × 40 mm · approx. 500 g |
Final measurement performance depends on electrode type, ISE membrane condition, calibration standards, sample matrix, ionic strength adjustment, temperature compensation settings and selected method. Electrode and accessory compatibility should be confirmed before quotation.
Calibration, ISE methods and GLP data management
Advanced pH and pX calibration
VIKING-ISE510 supports up to 8-point pH calibration and up to 6-point pX / ISE calibration. Multiple buffer groups and user-defined calibration options help adapt the instrument to routine and method-specific workflows.
Ion-selective methods
Direct Reading, Standard Addition, Sample Addition and GRAN methods support practical ISE workflows for common anions and cations, with selectable concentration units from mol/L to ppb.
GLP data handling
The instrument stores up to 1000 data groups per parameter and supports USB 2.0 output for structured review, export and traceable QA/QC documentation.
Portable workflow details
COLO.SCIENCE KNOWLEDGE
Learn more about water quality and electrochemical analysis
Explore COLO.Science resources covering pH meters, ion-selective electrodes, ORP measurement, buffer selection, calibration routines and practical water quality workflows.
Applications and laboratory value
Water quality laboratories
VIKING-ISE510 is suitable for pH, ORP and ion-selective measurement in drinking water, wastewater, surface water and process water samples.
Environmental monitoring
IP65 protection, rechargeable power and a carrying-case workflow make the meter practical for outdoor sampling and field checks.
Fertilizer and food QC
ISE methods can support selected ion analysis in fertilizer, food, beverage and agricultural quality-control workflows, depending on electrode selection.
Research and education
Touchscreen operation, multiple calibration options and clear GLP-style data management make VIKING-ISE510 practical for teaching laboratories and method development.
How to choose the correct ISE electrode and configuration
When selecting the VIKING-ISE510 portable pH/ion meter, the electrode and accessories should be chosen according to the target ion, expected concentration range, sample matrix, temperature, chemical compatibility and required method. Ion-selective electrode performance depends strongly on calibration standards, ionic strength adjustment, membrane condition and sample preparation.
COLO.Science can support the selection of ISE electrodes, pH electrodes, ORP electrodes, temperature probes, calibration standards, ISA solutions, storage solutions and accessories so that the final configuration matches the method and quotation.
VIKING-ISE510 portable pH/ion meter for field and laboratory ion measurement
The VIKING-ISE510 portable pH/ion meter is useful when a laboratory or field team needs one instrument for pH, ISE concentration, pX, ORP/mV and temperature. The combination of high pH accuracy, advanced ISE methods, GLP memory and IP65 protection supports both routine water testing and more specific ion-selective applications.
In practice, ion-selective measurement quality depends on the meter, selected electrode, calibration curve, standard solutions, sample matrix and operator workflow. VIKING-ISE510 provides the instrument platform, while COLO.Science can help define the correct electrode and accessory set for the final application.
Configuration notice
Portable pH/ion meters may be delivered in different configurations depending on selected ISE electrodes, pH electrodes, ORP electrodes, temperature probes, calibration standards, solutions and accessories. The official quotation defines the final scope of supply. Website content is provided for general product presentation and may not represent the exact delivered configuration. Specifications may change without notice.