Two Shops
One Shipment

VIKING-DO500 Benchtop DO Meter DO/Temp. (DO Saturation)


COLO.Science · Benchtop Dissolved Oxygen Meter

VIKING-DO500 is a benchtop DO meter for dissolved oxygen, DO saturation and temperature, with 7.0″ touchscreen, polarographic sensor, GLP/GMP data functions, USB/RS-232 and IP54 protection.

Key specs: DO 0.00–99.99 ppm · DO Sat. 0.0–600% · Temp. -10–135 °C · Polarographic · 4-pin aviation · USB 2.0/RS-232 · IP54 · SKU PRO3167

COLO.Science — WATER QUALITY / DISSOLVED OXYGEN — VIKING-DO500

VIKING-DO500 DO Meter

VIKING-DO500 DO meter is a benchtop dissolved oxygen instrument for
DO concentration, DO saturation and temperature measurement. It combines a
7.0″ high-contrast color LCD touchscreen, polarographic DO sensor technology,
GLP-compliant data storage, GMP log management, automatic barometric pressure compensation,
manual salinity correction, USB 2.0 and RS-232 communication, and IP54 protection
for routine water-quality laboratories, wastewater control, aquaculture, process monitoring and education.

Overview PDF Video soon RFQ

COLO.SCIENCE — BENCHTOP WATER QUALITY / DISSOLVED OXYGEN ANALYSIS

Benchtop DO meter for dissolved oxygen, DO saturation and temperature

The VIKING-DO500 DO meter is designed for laboratories that require a compact benchtop instrument
for dissolved oxygen concentration, oxygen saturation and temperature measurement. The 7.0″ touchscreen gives direct access
to calibration, method setup, reading modes, data management and log management.

VIKING-DO500 supports air-saturated water or zero oxygen calibration, automatic barometric pressure compensation,
manual salinity factor correction and selectable pressure units. It is suitable for routine water testing,
wastewater laboratories, aquaculture, process water monitoring and teaching laboratories.

Key features

  • Benchtop DO meter for dissolved oxygen, DO saturation and temperature.
  • 7.0″ high-contrast color LCD touchscreen for direct operation and result review.
  • DO range 0.00 to 99.99 ppm with 0.01 ppm resolution.
  • DO saturation range 0.0 to 600% with 0.10% resolution and ±2.0% accuracy.
  • Automatic barometric pressure compensation and manual salinity factor correction.
  • USB 2.0 and RS-232 communication for PC, printer, scanner, flash memory or autosampler workflow.

Suitable for

  • Drinking water, wastewater and surface-water laboratories.
  • Aquaculture, fisheries and aeration control.
  • Environmental testing and process-water quality monitoring.
  • Routine QA/QC checks where DO concentration and saturation are evaluated together.
  • Education, research and dissolved oxygen method training.
  • Laboratories requiring GLP storage, GMP logs and connected result export.

TECHNICAL SPECIFICATIONS — VIKING-DO500 DO METER

Instrument VIKING-DO500
Model DO-500T
SKU / Product number PRO3167
Product type Benchtop dissolved oxygen meter with touchscreen
Measured parameters DO / temperature / DO saturation
Sensor type Polarographic
Display 7.0″ color high-contrast LCD touchscreen, backlight
DO range 0.00 to 99.99 ppm
DO accuracy profile 0.00–50.00 ppm: ±0.10 ppm · 50.0–99.99 ppm: ±0.50 ppm
DO resolution 0.01 ppm
Calibration reminder Yes
Calibration points Air-saturated water or zero oxygen point
DO saturation range 0.0 to 600%
DO saturation resolution / accuracy 0.10% · ±2.0%
Temperature range -10 to 135 °C / 14 to 275 °F
Temperature resolution / accuracy 0.1 · ±0.1 °C
Temperature units °C, °F
Temperature compensation ATC / MTC
Barometric compensation Automatic
Salinity correction Manual salinity factor correction
Selectable pressure units kPa, mbar, Torr, Atm
Reading modes Auto-Read Fast / Medium / Slow, Timed, Continuous
Reading prompts Reading, Stable, Locked
Data storage 1000 groups, GLP-compliant
Log management Yes, GMP log support
Data analysis Review, compare and recalculate results
DO probe input DO with temperature probe, 4-pin aviation connector
USB USB 2.0 — flash memory device, PC, scanner
RS-232 Printer, auto-sampler
Factory reset Factory default restore
Date and time Yes
Auto shutdown 1–60 min or off
IP rating IP54
Power AC adapter, 100–240 V AC input, DC 24 V output
Dimensions / weight 220 × 195 × 68 mm · 950 g
Included / typical kit PRO6163 polarographic DO electrode kit with membrane covers, zero oxygen calibration solution, dissolved oxygen electrolyte, 3 membrane covers, touch pen and COLO-6 electrode stand

Final DO measurement performance depends on probe condition, membrane quality, electrolyte status, calibration routine,
sample temperature, pressure compensation, salinity correction and laboratory handling. Confirm final kit contents and accessories before ordering.

Calibration, compensation and GLP/GMP data management

DO calibration workflow

VIKING-DO500 supports air-saturated water calibration and zero oxygen calibration. The calibration reminder helps maintain routine traceability for dissolved oxygen measurements.

Pressure and salinity correction

Automatic barometric pressure compensation and manual salinity factor correction support reliable measurement across freshwater, wastewater, process water and high-ionic-strength samples.

GLP data and GMP logs

The instrument stores 1000 data groups and supports GLP records, GMP log management, result review, comparison and recalculation for laboratory documentation.

COLO.SCIENCE VIDEO

VIKING-DO500 video presentation is in preparation

The video will show touchscreen operation, DO calibration, probe preparation, membrane and electrolyte workflow,
salinity and pressure correction, GLP/GMP data handling and practical benchtop use.

Video soon

Benchtop dissolved oxygen workflow

VIKING-DO500 benchtop DO meter main unit with 7 inch touchscreen
7.0″ touchscreen main unit for DO concentration, DO saturation and temperature.

DO electrode kit

Typical delivery includes the PRO6163 polarographic DO electrode kit with membrane covers, zero oxygen solution,
dissolved oxygen electrolyte, touch pen and COLO-6 electrode stand.

Connected reporting

USB 2.0 and RS-232 outputs support PC, flash memory, scanner, printer and autosampler workflows for structured result documentation.

COLO.SCIENCE KNOWLEDGE

Learn more about water quality and electrochemical analysis

Explore COLO.Science content about dissolved oxygen, water-quality testing, electrochemical measurement,
calibration workflows and laboratory instrument selection.

COLO.Science articles →

Applications and laboratory value

Water and wastewater laboratories

VIKING-DO500 is suitable for dissolved oxygen measurement in drinking water, wastewater, surface water and process-water samples.

Aquaculture and environmental control

DO concentration and DO saturation are important for aquaculture, fisheries, aeration control and environmental water monitoring.

Industrial and process QA/QC

The instrument supports routine checks where oxygen level, temperature, pressure compensation, salinity correction and result documentation are required.

Education and method training

Touchscreen operation, calibration routines, GLP storage and GMP logs make VIKING-DO500 useful for teaching laboratories and applied method training.

Selecting the right DO configuration

When selecting the VIKING-DO500 DO meter, the user should consider sample type, expected DO range,
temperature, salinity, barometric-pressure conditions, reporting workflow and probe maintenance requirements.
Polarographic DO measurement requires attention to membrane condition, electrolyte status and calibration routine.

COLO.Science can support configuration with the appropriate DO electrode, zero oxygen solution, electrolyte, membrane covers,
electrode stand, communication workflow and documentation package for laboratory, environmental or process applications.

VIKING-DO500 DO meter for dissolved oxygen testing

VIKING-DO500 DO meter is a practical choice when a laboratory needs a benchtop dissolved oxygen meter
for DO concentration, DO saturation and temperature. The large touchscreen, polarographic sensor support,
GLP storage, GMP logs and USB/RS-232 communication make the instrument suitable for routine water-quality work
and connected laboratory documentation.

In daily use, dissolved oxygen results depend on calibration discipline, probe condition, membrane covers, electrolyte handling,
sample temperature, salinity correction and barometric compensation. VIKING-DO500 provides the measurement platform, while
COLO.Science can help define the correct accessories and maintenance items for the final workflow.

Configuration notice

Dissolved oxygen meters may be delivered in different configurations depending on selected probe, electrolyte, membrane covers,
calibration materials, electrode stand, communication accessories and local stock. The official quotation defines the final scope of delivery.
Website content is intended for general product presentation and may not represent the exact delivered configuration.
Specifications may change without prior notice.

Need a configuration for the VIKING-DO500 DO meter?

Contact COLO.Science for DO meter selection, electrode configuration, calibration materials, spare membranes,
accessories, technical documentation and quotation support.

Send request PDF Spec HTML Spec Video soon
SKU: PRO3167 Category:
Measurement Parameters

Conductivity

Instrument Type

Benchtop

Request a Quote