COLO.Science — Electrochemistry · Titration
TITRO5 Automatic Potential Titrator
TITRO5 is an automatic potentiometric titrator for acid-base, redox and precipitation titrations. It combines a 7″ colour touchscreen with guided operation, a replaceable high-accuracy burette (10 or 20 mL), DET, MET, SET and MAT titration modes, pH and mV measurement (0.000–20.000 pH, ±2000.00 mV), automatic temperature compensation, 100 user methods, 200 GLP result sets with curves, USB / RS-232 connectivity and autosampler support.
Overview
Applications
- Acid-base titration: acidity, alkalinity, acid number, TAN / TBN with the pH electrode.
- Redox titration: COD, permanganate, iodometric and dichromate methods with the platinum electrode.
- Precipitation titration: chloride, salt and silver methods with the silver electrode.
- Routine QC and research: methods, formulas and GLP records for repeatable results.
Why TITRO5
- Automatic dosing: replaceable burette, resolution 1/30000, accuracy ±0.020 mL (10 mL).
- Four modes: DET and MET equivalence point, SET preset endpoint and MAT manual titration.
- Methods and data: 100 methods, 10 shortcuts, auto calculation, 200 results with curves.
- Connectivity: USB / RS-232 to PC and printer, autosampler, optional second burette.
Technical specifications
| Model | TITRO5 |
| SKU | PRO3380 |
| Titration modes | DET, MET, SET, MAT |
| Burette | 10 mL standard, 20 mL optional |
| Burette accuracy | ±0.020 mL (10 mL), ±0.030 mL (20 mL) |
| Burette resolution | 1/30000 |
| Repeatability | ≤0.2 % |
| pH range | 0.000–20.000 pH |
| pH resolution | 0.001 pH |
| pH accuracy | ±0.002 pH |
| mV range | −2000.00 to 2000.00 mV |
| mV resolution | 0.01 mV |
| mV accuracy | ±0.03 % or ±0.2 mV |
| Stability | ±0.3 mV / 3 h |
| Temperature | −5.0 to 105.0 °C, ±0.2 °C |
| Display | 7″ colour touchscreen |
| Methods | 100 user methods, 10 shortcuts |
| Data memory | 200 results with curves, GLP |
| Interfaces | USB, RS-232 (PC, printer), autosampler |
| Power supply | AC adapter, DC 24 V |
| Dimensions | 340 × 400 × 400 mm |
| Weight | approx. 10 kg |
COLO.SCIENCE VIDEO
TITRO5 operation video
Unboxing, installation, operation, methods, cleaning and system settings — step by step.
TITRO5 operation video (5:03). Open the video in a new window
ELECTRODES AND ACCESSORIES
Electrodes and accessories for the TITRO5 titrator
TITRO5 is delivered with a 10 mL burette, pH glass electrode 231-01, platinum 213-01, silver 216-01, reference electrodes 232-01 and 217-01, temperature probe T-818-B-6 and pH buffer powders.
10 mL
Burette unit 10 mL (with valve)
Replaceable high-accuracy burette with valve; 20 mL burette available.
Standard delivery
PRO6178
Platinum electrode 213-01
Platinum indicator electrode, BNC (Q9).
Standard delivery
PRO6179
Silver electrode 216-01
Silver indicator electrode, BNC (Q9).
Standard delivery
PRO6175
Reference electrode 217-01 (double junction)
Saturated double-junction calomel reference electrode, U-shape terminal.
Standard delivery
PRO6172
Reference electrode 232-01
Saturated single-junction calomel electrode, U-shape terminal.
Standard delivery
PRO6169
Temperature probe T-818-B-6
316 stainless steel, Φ4×120 mm, −5…105 °C, BNC (Q6).
Standard delivery
PRO6180
pH titration electrode 982201
Conventional glass pH titration electrode, S7 head.
Optional
PRO6183
Silver titration electrode 981121
Combined silver electrode, PTFE body, S7 head.
Optional
More titration electrodes and accessories
- PRO6141 — pH indicator (glass) electrode 231-01
- PRO6121 — pH buffer powder 4.01 / 7.00 / 10.01
- PRO6181 — Pollution-resistant pH titration electrode 982202
- PRO6182 — Non-aqueous pH titration electrode 982211
- PRO6127 — 3 M KCl electrolyte powder
Tell us your titration method and we will confirm the right electrodes and burette for TITRO5. Full electrode range: Electrochemistry catalogue →
Selection guidance
TITRO5 is selected when a laboratory needs automatic, documented potentiometric titration with methods and curves. For simple manual titration choose TITRO20.
Configuration checklist
- Titration type: acid-base, redox, precipitation — determines the electrodes.
- Titrant volume: 10 or 20 mL burette; second burette for two titrants.
- Sample throughput: autosampler for series of samples.
- Documentation: printer or PC software for GLP reports.
Sales and support for international customers
COLO Lab ExpertsPolje ob Sotli 4, SI-3255 Buče, Slovenia
Phone: +386 70 713 437 · Email: sales@colo.si · Web: colo.si
We supply laboratories across Europe directly and through partners. B2B prices are quoted net, excluding VAT.