Two Shops
One Shipment

Nichiryo Premium Tips LG 100–1000 µL


COLO.Science · Pipette Tips

100–1000 µL · Bulk, rack and sterile rack · DNase/RNase free · Autoclavable · For 1000 µL Nichiryo pipettes, F2 500/1000 µL and V II 200/500/1000

COLO.Science · Pipette Tips · Nichiryo Premium

Nichiryo Premium Tips LG 100–1000 µL · Bulk, Racks and Sterile Racks

Nichiryo Premium Tips 100–1000 µL are the 1000 µL Premium tip (81.9 mm) for sample preparation, buffers and extractions. The finely finished tip end reduces surface tension, so the tip empties completely, and the precise seal on the pipette cone supports accurate, repeatable results. Choose bulk bags, racks or sterile racks.

Nichiryo Premium tips 100–1000 µL for Nichiryo pipettes

Nichiryo Premium Tips 100–1000 µL in rack

Key features

  • Finely finished tip end reduces surface tension – the tip empties without residue
  • Precise sealing on the pipette cone for accurate, repeatable pipetting
  • Highly purified polypropylene, chemical and heat resistant
  • Autoclavable at 121 °C for 20 minutes; racks can be autoclaved as well
  • DNase / RNase free, UV resistant
  • Tip length 81.9 mm, universal fit

Packaging options

Choose the packaging that fits your workflow. All versions are the same Nichiryo Premium tip LG.

Nichiryo Premium Tips 100–1000 µL – bulk bag

Bulk bag

1000 pcs · non-sterile

Economical for routine work and for refilling your own racks. Autoclave the tips in a rack or glass container before sterile work.

Nichiryo Premium Tips 100–1000 µL – rack

Rack

960 pcs (10 × 96) · non-sterile

Tips are picked up directly from the rack, so they stay clean and free of dust. Rack and tips can be autoclaved.

Nichiryo Premium Tips 100–1000 µL – sterile rack

Sterile rack

960 pcs (10 × 96) · sterile

Supplied sterile and ready to use for microbiology, cell culture and molecular biology.

Technical specifications

Tip

Tip type Nichiryo Premium tip LG
Volume range 100–1000 µL
Tip length 81.9 mm
Material highly purified polypropylene
Colour natural (clear)
Autoclaving 121 °C, 20 min (racks too)
Purity DNase / RNase free; UV resistant
Fit universal fit

Packaging

Bulk bag 1000 pcs, non-sterile
Rack 960 pcs (10 × 96), non-sterile
Sterile rack 960 pcs (10 × 96)

Where Nichiryo Premium tips 100–1000 µL are used

Nichiryo tests its pipettes with Premium tips, so a Premium tip on a Nichiryo pipette gives the accuracy stated for the pipette.

  • Sample preparation – extractions, digestions and transfers from 100 µL to 1 mL.
  • Buffers and reagents – preparation of working solutions and dilutions.
  • Microbiology and cell culture – sterile racks for media and suspensions.
  • Analytical chemistry – aliquots of standards and samples for ICP, AAS and chromatography.

Compatible Nichiryo pipettes

These Nichiryo pipettes take Nichiryo Premium tips LG. Premium tips have a universal fit – for pipettes of other brands, ask us for a sample to test the fit:

How to choose

  • Routine work, own racks – bulk bag.
  • Fast work straight from the rack – rack.
  • Microbiology, cell culture, molecular biology – sterile rack.
  • PCR and aerosol-sensitive samples – filter tips in sterile racks, see Nichiryo Low Retention tips.
  • Other sizes – see all Nichiryo Premium tips.
  • Economical tips for routine pipetting – see NichimateAqua tips.

Handling tips for accurate results

  • Press the pipette firmly into the tip with a slight twist – a tight seal is the basis of accurate pipetting.
  • Pre-wet the tip two or three times before the measured aspiration.
  • Hold the pipette vertically and immerse the tip just below the liquid surface.
  • Use a new tip for every sample; with sterile work open the rack only next to the working area.
  • Autoclave at 121 °C for 20 minutes – longer cycles or higher temperatures may deform tips and racks.

More methods and application notes on pipetting are available in our knowledge base.

Questions about Nichiryo Premium tips LG

Can Nichiryo Premium tips be autoclaved?
Yes – at 121 °C for 20 minutes, and the racks can be autoclaved as well. Longer cycles or higher temperatures may deform tips and racks.

Are the tips DNase / RNase free?
Yes. Nichiryo Premium tips LG are DNase / RNase free and UV resistant. For aseptic work choose the sterile rack.

Do the tips fit pipettes of other brands?
Nichiryo Premium tips have a universal fit. Tell us the make and model of your pipette and we will send a sample to test the fit before you order.

Which packaging should I order?
Bulk bags are the most economical choice if you refill your own racks. Racks keep the tips clean and are quick to use, and sterile racks are ready for microbiology, cell culture and molecular biology.

How do I order?
Send us the pipette model, the tip type (LG), the packaging and the quantity. COLO.Science will send a quotation with net prices and delivery time.

Sales and support for international customers

COLO Lab ExpertsPolje ob Sotli 4, SI-3255 Buče, Slovenia
Phone: +386 70 713 437 · Email: sales@colo.si · Web: colo.si
We supply laboratories across Europe directly and through partners. B2B prices are quoted net, excluding VAT.

Need help choosing pipette tips?

Tell us your pipettes, the liquids you work with and your monthly consumption. COLO.Science will recommend the right tips and packaging.

SKU: N/A Category:

Technical Specification

Packaging

Bulk bag, 1000 pcs, non-sterile, Rack, 960 pcs (10 × 96), non-sterile, Sterile rack, 960 pcs (10 × 96)

Tips purity

,

Tips suitable for

You may also like…