MTS200 / MTS400 Microplate Thermo Shaker Incubator
MTS200 / MTS400 Microplate Thermo Shaker Incubator is a compact laboratory platform designed for controlled incubation, heating and shaking of microtiter plates, deep well plates and culture plates. With a temperature range of RT+5°C to 70°C, mixing speed of 100–1600 rpm, 3 mm mixing amplitude, PID intelligent temperature control, 4.3 inch TFT / LCD display, brushless DC motor, timed operation and power failure recovery, the MTS series is suitable for sample incubation, catalysis, enzymatic reactions, biochemical workflows and routine microplate-based laboratory work.
RT+5°C to 70°C
100–1600 rpm
2 or 4 plates
3 mm amplitude
PID control
TFT 4.3 inch
Timer 1–9999 min

COLO.SCIENCE — SAMPLE PREPARATION / MICROPLATE THERMO SHAKER INCUBATORS
Microplate thermo shaker incubator for controlled incubation and timed shaking
The MTS200 / MTS400 Microplate Thermo Shaker Incubator is designed for laboratories that need controlled temperature, stable shaking and repeatable timed operation in plate-based workflows. It combines microplate incubation and shaking in one compact bench-top instrument, helping reduce manual transfer between separate heating and mixing devices.
MTS200 supports up to 2 microtiter or deep well plates, while MTS400 supports up to 4 microtiter or deep well plates. Both models share the same main temperature range, mixing speed range, 3 mm amplitude, PID temperature control concept and timed operation functions.
Key features
- Microplate thermo shaker incubator for heating, incubation and controlled shaking.
- Temperature range RT+5°C to 70°C for routine plate incubation and reaction workflows.
- Mixing speed 100–1600 rpm with high precision speed control and ±1 rpm speed accuracy.
- 3 mm mixing amplitude for practical microplate-based mixing.
- PID intelligent temperature control with ±0.3°C temperature control accuracy.
- 4.3 inch TFT / LCD display showing operating and setting information in real time.
Suitable for
- Microtiter plate, deep well plate and culture plate incubation workflows.
- Sample incubation, catalysis and temperature-controlled reaction processes.
- Enzymatic reactions and biochemical plate-based workflows.
- Diagnostic, research, bioanalytical and quality control laboratories.
- Laboratories requiring continuous or timed shaking with audio alarm.
- Users choosing between two-plate and four-plate microplate throughput.
TECHNICAL SPECIFICATIONS — MTS200 / MTS400 MICROPLATE THERMO SHAKER INCUBATOR
| Model | MTS200 | MTS400 |
| Product type | Microplate thermo shaker incubator | Microplate thermo shaker incubator |
| Capacity | 2 × microtiter or deep well plates | 4 × microtiter or deep well plates |
| Temperature range | RT+5°C to 70°C | |
| Heating method | Peltier / thin-film heating system* | |
| Mixing speed | 100–1600 rpm | |
| Temperature control accuracy | ±0.3°C | |
| Temperature uniformity | ±0.5°C | |
| Temperature resolution | 0.1°C | |
| Maximum heating speed | 5.5°C/min | |
| Mixing amplitude | 3 mm | |
| Speed accuracy | ±1 rpm | |
| Display | TFT / LCD 4.3 inch display | |
| Drive mode | Multidimensional drive | |
| Overheating protection | Yes | |
| Cooling system | No | |
| Rated power | 180 W | 200 W |
| Timer | 1 min to 9999 min | |
| Temperature sensor | Pt100 A Class | |
| Power supply | AC220V±10% / 50/60Hz | |
| Overall dimension W × D × H | 280 × 270 × 140 mm | 329 × 359 × 172 mm |
| NW / GW | 9 / 10 kg | 10 / 11 kg |
| Optional accessories | Blocks, thermo lid, communication port | |
| HTML / PDF TechSpec | Open MTS200 / MTS400 HTML technical specification · Download MTS200 / MTS400 PDF technical specification | |
Operation and control functions
- Setting or program running, timing running, automatic stop and quick stop / start.
- Continuous or timed shaking with audio alarm after the set time expires.
- Microcomputer control of temperature and oscillation frequency with timing functions.
- Built-in power-off protection and automatic resume after power restoration.
- Temperature deviation correction, menu button lock and power failure memory.
- Intelligent brushless DC motor with high precision speed control and slow start design.
* Source data references both thin-film heating and Peltier heating system wording. Final manufacturer-confirmed wording should be checked before formal quotation or procurement documentation.
Instrument views and model configuration
MTS200 and MTS400 are selected according to plate capacity and daily workflow volume. MTS200 provides compact two-plate operation for routine incubation and shaking, while MTS400 provides a four-plate format for laboratories that process more plates per run.
MTS200 main unit
Compact two-plate microplate thermo shaker incubator for routine laboratory workflows.
MTS200 open lid
Open-lid view showing the plate chamber and working platform.
MTS400 four-plate model
Four-plate configuration for higher microplate throughput.
COLO.SCIENCE KNOWLEDGE
Learn more about thermo shaker incubators in practice
Explore COLO.Science resources covering dry block incubators, thermo shakers, microplate shaking and sample preparation workflows for molecular biology, diagnostics and quality control.
Applications and laboratory value
Sample incubation
MTS200 / MTS400 supports temperature-controlled incubation of microtiter plates, deep well plates and compatible culture plate formats.
Catalysis and reaction processes
Controlled heating and mixing help shorten experimental operation time and support catalysis, enzymatic reaction workflows and biochemical reaction steps.
Timed microplate shaking
Continuous or timed shaking with audio alarm and automatic stop helps standardize repetitive plate-based protocols.
Research, diagnostic and QC laboratories
The series is suitable for routine microplate handling in diagnostic, research, bioanalytical and quality control laboratory environments.
How to choose between MTS200 and MTS400
When selecting a microplate thermo shaker incubator, the laboratory should define plate type, number of plates per run, working temperature, shaking speed, timing requirements and accessory needs. MTS200 is the practical choice for compact two-plate workflows, while MTS400 is selected when four-plate throughput is required.
Both models share the same core performance class: RT+5°C to 70°C temperature range, 100–1600 rpm mixing speed, 3 mm mixing amplitude, PID temperature control, timer range from 1 minute to 9999 minutes and safety functions such as overheating protection, menu lock and power failure memory.
MTS200 / MTS400 as a microplate shaker incubator for daily laboratory work
MTS200 / MTS400 Microplate Thermo Shaker Incubator is useful when a laboratory needs one compact platform for controlled heating, incubation and repeatable shaking of microplates. Instead of using separate heating and shaking devices, users can perform plate incubation, timed mixing, sample preparation and reaction workflows in one bench-top system.
The RT+5°C to 70°C temperature range and 100–1600 rpm mixing speed support many routine plate-based protocols. MTS200 is well suited for moderate daily throughput, while MTS400 provides additional capacity for laboratories that process more plates per run. For laboratories focused on microplate incubation, enzymatic reactions, catalysis, diagnostics and QC workflows, the MTS series provides a direct and practical solution.
Configuration notice — plate workflow and accessories should be confirmed before quotation
MTS200 and MTS400 are typically selected according to plate capacity, plate type, incubation temperature, shaking speed, timer workflow and accessory configuration.
Optional accessories such as blocks, thermo lid and communication port should be confirmed before quotation.
The content shown on this website is provided for general information and may not represent the final delivered configuration.
MTS200 / MTS400 — controlled incubation and shaking for microplate workflows
Compact microplate thermo shaker incubators with RT+5°C to 70°C temperature range, 100–1600 rpm mixing speed, 2-plate or 4-plate capacity, PID temperature control, timed operation, automatic protection functions and support from COLO.Science.