COLO.Science · Spectroscopy & Color · Benchtop spectrophotometers
CS6080 Benchtop Spectrophotometer — reflectance d/8 and transmittance d/0
The CS6080 benchtop spectrophotometer (COLO product code PRO7904) measures reflectance and transmittance colour of plastics, coatings, films, liquids and powders in one instrument. A pulsed xenon lamp with 400, 420 and 460 nm UV cut-off, a 154 mm integrating sphere and simultaneous SCI/SCE give repeatable CIE Lab and ΔE values for colour formulation and colour quality control.
Benchtop or portable spectrophotometer?
Highest agreement · full UV controlCS6080Pulsed xenon · UV cut-off 400/420/460 nm · ΔE*ab ≤ 0.12 inter-instrument · Bluetooth · transmittance component included
Xenon · basic modelCS6020Pulsed xenon · UV cut-off 400 nm · ΔE*ab ≤ 0.15 inter-instrument · transmittance component optional
Portable · at the lineSC810Hand-held d/8 · LED · 400–700 nm · Ø 8 mm · ΔE*ab 0.04 · battery · liquids and powders with test componentOverview
The CS6080 is the instrument to choose when results must agree closely with other laboratories and when UV content matters: the xenon source with three UV cut-off filters handles fluorescent and optically brightened samples, and inter-instrument agreement is within ΔE*ab 0.12 on twelve BCRA Series II tiles.

Key characteristics
- Reflectance d/8 and transmittance d/0, SCI and SCE measured simultaneously
- Pulsed xenon lamp 360–780 nm with 400, 420 and 460 nm UV cut-off
- Repeatability ΔE*ab ≤ 0.012 (reflectance) and ≤ 0.015 (transmittance)
- Inter-instrument agreement ΔE*ab ≤ 0.12
- Reflectance apertures Ø30/25.4, 18/15, 10/8 and 6/4 mm, recognised automatically
- Haze per ASTM D1003, built-in camera, USB and Bluetooth
Suitable for
- Opaque and translucent plastic plaques, masterbatch and compounds
- Paints, coatings, inks and pigments; textiles and paper
- Films, sheets and glass in transmittance; liquids in cuvettes
- Colour quality control with CIE Lab (D65/10°) and ΔE pass/fail
Why this instrument
Two things decide the price of a colour mistake: a batch that is released and later rejected, and a dispute about whose numbers are right. The CS6080 addresses both — repeatability of ΔE*ab 0.012 keeps a pass/fail decision stable, and tight inter-instrument agreement means values measured here can be compared with values measured on another instrument of the same class.
Reflectance, transmittance and sample handling
Technical specifications
Optics and performance
| Geometry | Reflectance d/8, transmittance d/0, SCI + SCE, UV included / excluded |
| Standards | CIE No.15, ISO 7724/1, ASTM E1164, DIN 5033 Teil 7 |
| Light source | Pulsed xenon lamp; 400, 420 and 460 nm cut-off |
| Integrating sphere | Ø 154 mm |
| Spectral system | Concave grating, 256-element double-array CMOS sensor |
| Wavelength range · pitch | 360–780 nm · 10 nm |
| Half bandwidth | 5 nm |
| Reflectance range | 0–200 % |
| Apertures, reflectance | Ø30/25.4, Ø18/15, Ø10/8, Ø6/4 mm |
| Apertures, transmittance | Ø30/25 mm |
| Repeatability | Reflectance ΔE*ab ≤ 0.012 · transmittance ΔE*ab ≤ 0.015 (Ø25.4 mm, SCI) |
| Inter-instrument agreement | ΔE*ab ≤ 0.12 (Ø25.4 mm, SCI, 12 BCRA II tiles) |
| Interfaces · storage | USB, Bluetooth, printer port · 5 000 standards, 40 000 samples |
Colour data and general
| Colour spaces | CIE Lab, XYZ, Yxy, LCh, CIE LUV, Hunter Lab, Munsell, s-RGB, DIN, βxy |
| Colour difference | ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc (2:1 and 1:1), ΔE*00, ΔE Hunter, DIN ΔE99 |
| Indices | WI, YI, metamerism index, APHA/Hazen/Pt-Co, Gardner, Saybolt, 555 index, colour fastness and staining, colour strength, opacity, haze (ASTM D1003) |
| Observer · illuminants | 2° and 10° · D65, A, C, D50, D55, D75, F1–F12, CWF, DLF, TL83, TL84, TPL5, U30 |
| Measuring time | approx. 2.4 s (SCI + SCE approx. 5 s) |
| Display | 7″ TFT capacitive touch screen |
| Power supply | DC 24 V, 3 A adapter |
| Lamp life | 5 years, more than 3 million measurements |
| Dimensions (W × D × H) | 370 × 300 × 200 mm |
| Net weight | approx. 9.6 kg |
| Operating environment | 0–40 °C, 0–85 % RH, non-condensing |
Software and data

The PC software stores standards with their tolerances, shows the spectrum, the colour plot and the colour difference, and exports results for reports and archiving. Quality-control and sample modes are also available directly on the 7″ touch screen.
Reflectance and transmittance results are kept in the same database, so one standard can be checked in both modes.
Standard delivery
- Instrument with white calibration tile and black calibration cavity
- Reflectance apertures Ø25.4, 15, 8 and 4 mm and sample holder
- Transmittance test component and black baffle
- PC software, USB cable, DC 24 V power adapter, user guide
Optional: micro-printer, Ø4 mm transmittance clamp, inversion component, culture dish, custom apertures. The delivered configuration for a specific order is the one confirmed in the COLO.Science quotation.
Knowledge base
New to colour measurement? Light sources, metamerism, CIE Lab, ΔE and measuring geometries are explained on COLO.Science, our knowledge base.
Selection guide
- Close agreement with other laboratories, fluorescent samples: CS6080 — three UV cut-off filters and ΔE*ab ≤ 0.12 between instruments.
- Second instrument for daily checks, budget first: CS6020 — same xenon principle and geometries at a lower price.
- Transmittance or haze: both models; with the CS6020 order the transmittance test component.
- Large or curved parts at the production line: a portable spectrophotometer is the better tool — ask us for the right model.
Configuration notice
This page is provided for orientation and product selection. Sample type, apertures, transmittance accessories and the colour data you report are confirmed with the official COLO.Science quotation.
Sales and support for international customers
COLO Lab ExpertsPolje ob Sotli 4, SI-3255 Buče, Slovenia
Phone: +386 70 713 437 · Email: sales@colo.si · Web: colo.si
We supply laboratories across Europe directly and through partners. B2B prices are quoted net, excluding VAT.