COLO.SCIENCE — INTERNAL CALIBRATION MILLIGRAM LABORATORY WEIGHING
1 mg readability with internal calibration, EMC load cell and RS232C output
MILIX is a milligram precision balance platform for laboratories that need stable 0.001 g readability, internal calibration and a practical integrated windshield for routine weighing. The EMC electromagnetic compensation load cell, anti-vibration filter, LCD backlight display and RS232C interface make the series suitable for QC laboratories, sample preparation, formulation, research and teaching laboratory workflows.
The MILIX series includes 300g/1mg, 500g/1mg and 620g/1mg sales SKU configurations. The technical family mapping uses MILIX300, MILIX500 and MILIX600 models with technical maximum capacities of 320 g, 520 g and 620 g. Final model, SKU, delivered label, accessories and documentation package should be confirmed in the official quotation.
Key characteristics
- Catalogue SKU codes: PRO5309, PRO5310 and PRO5311.
- Sales SKU range: MILIX 300g/1mg, MILIX 500g/1mg and MILIX 620g/1mg.
- Technical family models: MILIX300, MILIX500 and MILIX600.
- Technical maximum capacities: 320 g, 520 g and 620 g.
- Readability / resolution: 0.001 g / 1 mg.
- Minimum weighing: 4 mg.
- Repeatability: ±2 mg.
- Linearity: ±2 mg.
- Stabilization time: ≤1.5 s.
- Internal calibration with integrated calibration weight.
- EMC electromagnetic compensation load cell with anti-vibration filter.
- RS232C interface for printer, PC or laboratory data workflow.
Suitable for
- Routine milligram weighing with 1 mg readability.
- Sample preparation, formulation and reagent weighing.
- Quality control checks and research laboratory weighing.
- Teaching laboratories and daily analytical weighing tasks.
- Check weighing, parts counting and percentage weighing.
- Documented weighing with optional RS232 printer or PC output.
- Routine independent verification with optional OIML F1 control weights.
MILIX SERIES — PRACTICAL SELECTION FOR INTERNAL CALIBRATION MILLIGRAM WEIGHING
MILIX milligram balance for routine laboratory tasks
MILIX milligram balance is suitable when a laboratory needs reliable 1 mg weighing, internal calibration, EMC load cell performance and a compact integrated windshield. With sales SKU configurations for 300g/1mg, 500g/1mg and 620g/1mg, the MILIX series covers routine laboratory tasks such as sample preparation, small formulations, mass control, QC checks, research weighing, parts counting and percentage weighing.
When selecting a model, MILIX milligram balance should be matched to the maximum total load on the pan: sample, container, weighing vessel and any accessories used during the method. The MILIX 300g/1mg SKU is practical for smaller routine samples, the MILIX 500g/1mg SKU covers general laboratory use, and the MILIX 620g/1mg SKU provides the highest listed MILIX capacity.
For stable work, MILIX milligram balance should be installed on a calm and levelled bench, protected from vibration, air movement and rapid temperature changes. Internal calibration simplifies routine calibration, while optional OIML F1 control weights support independent verification checks according to laboratory SOP requirements.
MILIX balance, optional printer and OIML F1 control weights
MILIX series covers 300 / 500 / 620 g sales SKU configurations, 1 mg readability, internal calibration, EMC load cell, integrated windshield and RS232C output.
Optional RS232 printer supports direct printout of weighing results where laboratory procedures require paper documentation.
Optional OIML F1 control weights can be selected for independent routine verification checks, SOP requirements and documented laboratory procedures.
MILIX series — SKU and model configuration
MILIX 300g/1mg
SKU code: PRO5309
Sales SKU name: MILIX 300g/1mg
Technical family model: MILIX300
Order code: MILIX-300
Technical max capacity: 320 g
Readability: 0.001 g / 1 mg
Repeatability: ±2 mg
Linearity: ±2 mg
Calibration: Internal
Output: RS232C
MILIX 500g/1mg
SKU code: PRO5310
Sales SKU name: MILIX 500g/1mg
Technical family model: MILIX500
Order code: MILIX-500
Technical max capacity: 520 g
Readability: 0.001 g / 1 mg
Repeatability: ±2 mg
Linearity: ±2 mg
Calibration: Internal
Output: RS232C
MILIX 620g/1mg
SKU code: PRO5311
Sales SKU name: MILIX 620g/1mg
Technical family model: MILIX600
Order code: MILIX-600
Technical max capacity: 620 g
Readability: 0.001 g / 1 mg
Repeatability: ±2 mg
Linearity: ±2 mg
Calibration: Internal
Output: RS232C
SKU note: catalogue SKU codes are PRO5309 for MILIX 300g/1mg, PRO5310 for MILIX 500g/1mg and PRO5311 for MILIX 620g/1mg. The technical source maps these to MILIX300, MILIX500 and MILIX600 with maximum capacities 320 g, 520 g and 620 g respectively. Confirm final SKU, delivered label and capacity in the official quotation.
TECHNICAL SPECIFICATIONS — MILIX MILLIGRAM BALANCE SERIES
| Product series | MILIX milligram balance series |
| Catalogue SKU codes | PRO5309 / PRO5310 / PRO5311 |
| Sales SKU names | MILIX 300g/1mg / MILIX 500g/1mg / MILIX 620g/1mg |
| Technical family models | MILIX300 / MILIX500 / MILIX600 |
| Balance type | Milligram precision laboratory balance · Class II |
| Technical maximum capacity | 320 / 520 / 620 g |
| Readability / resolution | 0.001 g / 1 mg |
| Minimum weighing | 4 mg |
| Repeatability | ±2 mg |
| Linearity | ±2 mg |
| Stabilization time | ≤ 1.5 seconds |
| Calibration | Internal calibration; integrated calibration weight included |
| Sensor / weighing principle | EMC electromagnetic compensation load cell |
| Filtering | Anti-vibration filter for stable readings in normal laboratory environments |
| Display | LCD with backlight |
| System functions | Check weighing, parts counting, percentage weighing |
| Interface / output | RS232C |
| Windshield | Integrated windshield chamber |
| Pan size | Stainless steel Ø80 mm; optional Ø90 mm |
| Operating temperature | 15–25 °C; fluctuation < 5 °C/h |
| Relative humidity | 40–80% RH |
| Power supply | AC110–240 V, 50/60 Hz; DC5V-2A adapter |
| Optional battery | Rechargeable battery pack for operation away from mains power |
| Overall dimensions | 340 × 215 × 265 mm |
| Windshield dimensions | 225 × 220 × 265 mm |
| N.W. / G.W. | 3 kg / 10 kg |
Final weighing performance depends on installation quality, environmental stability, correct levelling, vibration control, warm-up routine, sample handling, internal calibration practice and selected control-weight procedure. Final model configuration, printer, cable, battery, F1 weights, certificates and documentation are confirmed in the official quotation.
Operating and weighing functions
Milligram weighing
MILIX supports routine 1 mg laboratory weighing for samples, reagents, standards, prepared solutions, ingredients and small containers in daily laboratory workflows.
Check weighing
Check weighing supports high/low limit control for routine QC checks, receiving control, batch checks and pass/fail laboratory decisions.
Parts counting
Parts counting mode supports small-component counting by reference mass where sample uniformity and reference preparation are appropriate.
Percentage weighing
Percentage weighing supports formulation, batch control and comparison workflows where mass is expressed relative to a reference value.
Internal calibration
The integrated calibration weight supports regular internal calibration without external weight handling during routine operation.
RS232C data output
RS232C output supports optional printer, PC collection or compatible laboratory documentation workflows.
STANDARD CONFIGURATION, OPTIONAL ACCESSORIES AND OIML F1 CONTROL WEIGHTS
Internal calibration, printer option and OIML F1 control-weight package
MILIX has internal calibration with an integrated factory-certified calibration weight. Optional OIML F1 control weights are recommended for independent routine verification checks according to the laboratory SOP. The set size, nominal masses and certificates should be selected according to the chosen MILIX capacity and customer procedure.

OIML F1 control weights
Recommended for independent routine checks, audit support, documented verification points and laboratory SOP compliance.
Optional RS232 printer
Supports direct printout of weighing results when laboratory procedures require printed measurement records.
Configuration logic
- Internal calibration for regular routine calibration.
- Integrated windshield for stable 1 mg weighing.
- RS232C output for printer, PC or compatible data workflow.
- Optional rechargeable battery pack for mains-independent use.
- Optional Ø90 mm pan where a larger weighing surface is required.
- F1 weights and certificates according to laboratory procedure.
Ordering note: final MILIX configuration should confirm SKU code, technical model, delivered label, capacity, printer, RS232 cable, optional battery, Ø90 mm pan, OIML F1 control weights, certificates and documentation requirements.
Standard delivery, options and data output
Typical standard delivery
Typical MILIX delivery includes the selected milligram balance, internal calibration system with integrated factory-certified calibration weight, universal power adapter, dust cover, instruction manual and integrated windshield.
Available options
Optional configuration may include RS232 printer, rechargeable battery pack, larger stainless steel Ø90 mm pan, OIML F1 control weights, calibration certificate, spare dust covers and windshield replacements.
RS232C data workflow
RS232C interface supports compatible printers, computers and laboratory data workflows. Exact communication requirements should be confirmed before quotation.
COLO.SCIENCE — APPLICATION AND CONFIGURATION SUPPORT
COLO.Science supports complete weighing configurations: balance selection, internal calibration routine, control-weight selection, certificates, printer workflows, RS232C interface requirements and documented weighing procedures for laboratory users.
Applications and operational value
Precision laboratory weighing
MILIX is suitable for accurate measurement of samples, reagents, standards and prepared solutions in QC, research and formulation workflows.
Internal calibration convenience
Integrated internal calibration reduces external handling during routine calibration and supports consistent laboratory operation.
Integrated windshield
The integrated windshield chamber reduces air-current influence on 1 mg measurements and supports stable readings during routine weighing.
Documentation workflow
RS232C connectivity supports optional printer use, PC data collection and laboratory documentation workflows.
How to select the appropriate MILIX model
When selecting a MILIX model, first define the maximum total mass on the pan: sample, container, weighing vessel and any accessories used during the method. The MILIX 300g/1mg SKU is a compact choice for smaller routine samples, the MILIX 500g/1mg SKU is a mid-range solution for general laboratory use, and the MILIX 620g/1mg SKU is the highest listed MILIX capacity.
The second selection step is documentation and verification. Choose the optional RS232 printer when paper records are required. Define the PC output workflow if results need to be collected digitally. For independent routine control checks, select OIML F1 control weights and certificates according to the laboratory SOP and the typical working mass range.
MILIX milligram balance for internal calibration 1 mg laboratory weighing
MILIX milligram balance is suitable for laboratories that need practical 1 mg weighing for routine samples, reagents, standards, formulation checks, QC workflows, parts counting and percentage weighing. The series combines EMC electromagnetic compensation load cell technology, internal calibration, anti-vibration filtering, LCD backlight display, integrated windshield, stainless steel pan and RS232C communication in a laboratory balance platform covering 300 / 500 / 620 g sales SKU configurations.
In practical use, MILIX performance depends on correct installation, stable temperature, suitable weighing bench, proper levelling, vibration control, internal calibration routine and a suitable independent control-weight procedure. Optional printer, RS232 accessories, rechargeable battery pack, larger Ø90 mm pan, additional F1 control weights and certificates can be added according to laboratory method and documentation requirements.
Configuration notice
MILIX milligram balance models may be supplied with different configurations depending on selected SKU, delivered model label, printer, communication accessories, optional battery, Ø90 mm pan, OIML F1 control weights, certificates and documentation requirements. The official quotation defines the final delivery scope, including confirmed SKU, capacity, accessory configuration and acceptance criteria. Website content is intended for general product presentation and may not represent the exact delivered configuration. Specifications may change without notice.