The USP-400 series handheld ultrasonic homogenizer uses ultrasonic cavitation for cell disruption, emulsification, dispersion, homogenization, extraction, defoaming, cleaning and nano-material preparation.

The series is available in two configurations: PRO5691 (2.5–250 W, 0.1–150 mL) and PRO5692 (4–400 W, 0.1–300 mL), each supplied with a Φ5 mm standard horn. Both models feature a true‑color capacitive touch display, automatic frequency tracking and real‑time sample temperature detection.

Why users switch to USP-400

  • 🟦
    Firstly, true handheld: 1.2 kg – move between laminar flow, fume hood, cold room.
  • 🟦
    No-load protection: Automatic shutdown if probe is in air. Saves tips and samples.
  • 🟦
    20 protocol memory: Switch from E. coli lysis to nanoparticle mixing instantly.
  • 🟦
    Temperature monitoring: Real-time °C shown on screen; optional cooling cell.
  • 🟦
    Duty cycle 0.1–99.9%: Gentle on antibodies and temperature‑sensitive enzymes.

Validated applications

  • 🧬
    In addition, cell biology: Mammalian, bacterial, yeast lysis – 30 s to 3 min.
  • ⚛️
    Material science: Graphene, CNT, metal oxide dispersion (0.1–2% wt).
  • 💧
    Formulation: Nanoemulsions, liposomes, cannabis oil emulsification.
  • 🍎
    Food & cosmetic: Particle size reduction, stability testing.
  • 🌍
    Environmental: Soil extraction, algae cell wall breaking.

Optimized ultrasonic settings for any sample type

PRACTICAL WORKFLOW – POWER & PULSE SETTINGS

How to get reproducible results (step‑by‑step)

1️⃣ Probe selection: Φ2 mm (0.1–5 mL), Φ3 mm (2–15 mL), Φ5 mm (10–150 mL), Φ6 mm (20–300 mL).
2️⃣ Amplitude check: Start at 30% duty cycle for delicate cells; 70–90% for hard tissues.
3️⃣ Pulse mode: Set ultrasound 3 s → gap 2 s → avoids thermal stress.
4️⃣ Depth control: Immerse probe 10–15 mm; never touch vessel bottom.
5️⃣ Memory save: Store successful runs (20 groups) – recall instantly.

🧪 COLO.Science quality commitment

Every USP‑400 is frequency‑swept and calibrated at our EU partner facility. We provide 12‑month warranty, 7‑year spare parts availability, and application protocols via email support.

🔧 Tip: Φ2, Φ3, Φ6 mm horns and flow‑cell attachments are in stock – ask for customisation.

USP-400 series model comparison – handheld ultrasonic homogenizer: power, volume and best use cases for PRO5691 and PRO5692
SKU / Model Power output (adjustable) Processing volume* Standard horn Ideal for Typical applications
PRO5691 2.5 – 250 W 0.1 – 150 mL Φ5 mm titanium Academic R&D, enzyme assays, DNA/RNA shearing, small-batch cell lysis E. coli, yeast, mammalian cells; nanoparticle dispersion up to 50 mL
PRO5692 4 – 400 W 0.1 – 300 mL Φ5 mm titanium Biotech scale‑up, tough tissues, high‑volume emulsification (100–300 mL) Plant tissue, liposomes, cannabis oil, graphene, pilot batches

* Processing volume depends on horn selection, sample viscosity and vessel geometry.

USP-400 series technical specifications – features shared by both PRO5691 and PRO5692 handheld ultrasonic homogenizers
Display True‑color capacitive TFT touch screen, 4.3″ (adjustable brightness)
Single ultrasound time 0.1 – 99.9 seconds (programmable)
Single gap (pause) time 0.1 – 99.9 seconds
Total process timer 1 second – 99 hours 59 minutes 59 seconds
Ultrasonic frequency 20 – 30 kHz (automatic frequency tracking – AFT)
Temperature monitoring 0 – 100 °C ±1 °C, real‑time display, compatible with optional cooling cell
Alarm & protection Time, overload, no‑load, over‑temperature – audible and visual alerts
Duty cycle 0.1 – 99.9 % (pulsed or continuous mode)
Program memory 20 groups – store and recall complete protocols
Optional probes (horns) Φ2 mm, Φ3 mm, Φ5 mm, Φ6 mm – titanium, autoclavable
Power supply 110–120 V / 220–240 V, 50/60 Hz (universal input)
Dimensions (net) 410 × 225 × 290 mm (D × W × H)
Weight ~3.8 kg (handheld unit with cable)
Optional interfaces Computer communication (RS‑232 / USB) + data printing

Frequently asked questions – USP-400 homogenizer

❓ What is the difference between PRO5691 and PRO5692?

PRO5691 is 250W max, processes 0.1–150 mL – entry level, lower cost. PRO5692 is 400W, reaches 300 mL, suited for tougher samples (plant tissue, high % solids). Both have identical UI and probe fitting.

❓ Can I use USP-400 for DNA shearing?

Yes. Use PRO5691 with Φ2 mm or Φ3 mm probe, set duty cycle ≤40%, pulse 2s on/2s off. The TFT screen lets you store the shearing protocol.

❓ Which accessories are included in the box?

Each USP-400 ships with: Φ5 mm titanium probe, foot switch, temperature sensor, power cord, quick start card. Probes are autoclavable.

❓ Is there a cooling jacket or flow cell?

Optional low‑temperature kit (cooling circulator + double wall vessel) available – contact sales. The temperature display works with any external probe.

📩 Finally, have a different question? Email sales@colo.si – reply within 4h (CET).

🔒 2‑year warranty
⚡ EU stock / fast ship
🧪 Application support
⭐ No reviews yet – be the first to validate!

🔗 More from COLO.Science:
All ultrasonic processors ·
Sample preparation ·
Homogenizers

 

SKU: PRO5692 Category:
Homogenizers

,

Request a Quote