Two Shops
One Shipment

Unfillable Polycarbonate pH composite electrode Ag/AgCl Φ12×120 mm BNC(Q9)


For routine checks · no refilling

pH 0–14 · Ag/AgCl · Sealed, no refilling · Polycarbonate · 5–60°C · BNC (Q9)

PRO6136 — unfillable polycarbonate pH composite electrode: the simplest electrode in the range: a sealed, non-refillable pH electrode with a polycarbonate body for routine checks of dilute aqueous samples and drinking water. It has a sealed Ag/AgCl reference that needs no refilling, a POM junction and a BNC (Q9) connector for the meter.

How the unfillable polycarbonate pH composite electrode is built

Spherical bulb
pH sensor
Spherical bulb
General-purpose glass membrane for common solutions.
Polycarbonate
Body
Polycarbonate
Unbreakable shaft for daily handling. Not for organic solvents.
POM
Junction
POM
Solvent-resistant junction used on non-refillable electrodes.
BNC (Q9)
Connector
BNC (Q9)
Fits pH meters with a BNC electrode input.

The reference system is Ag/AgCl. It is sealed, so the unfillable polycarbonate pH composite electrode has no electrolyte to check or refill.

Technical parameters

Model / order code PRO6136
Electrode type pH composite (combination) electrode
Measuring range pH 0 – 14
Working temperature 5 – 60 °C
pH sensor Hemispherical glass bulb
Body material Polycarbonate
Reference system Ag/AgCl
Junction POM
Fill solution None — sealed, non-refillable
Temperature sensor None
Dimensions Φ12 × 120 mm
Connector BNC (Q9)

Full data sheet: Technical Specification (PDF), two pages.

Is this the right electrode for your sample?

The unfillable polycarbonate pH composite electrode is recommended for: dilute acids and alkalis; tap and drinking water (approx. 100 µS/cm). It can also be used for: fixing and electroplating solutions; yogurt, cheese, butter; jam; cooking oils; soy sauce, vinegar; dyes, colouring agents, ink; water-based paint, varnish, coating, latex; sizing agents; gel, soap, shampoo, hair dye, lotion; soil leachate; mud.

Some samples need a different design. The selection by sample in the electrode catalogue shows which electrode is recommended for which sample; the most frequent cases are:

  • Samples above 60 °C: an electrode specified to 80 °C, or the high-temperature electrode to 120 °C.
  • Pure or low-conductivity water: a low-conductivity or ultrapure-water electrode.
  • Emulsions, suspensions, viscous samples: a cleanable or open-junction electrode.
  • One sensor instead of two: the 3-in-1 pH composite electrode with a built-in temperature sensor (ATC).

One electrode for benchtop and portable pH meters

The unfillable polycarbonate pH composite electrode does not belong to one meter. The same electrode works on a benchtop meter in the laboratory and on a portable meter in the field — what decides is the input of the meter, not its housing. Its BNC (Q9) connector fits every meter with a BNC input; see the pH meters in the catalogue.

Because the unfillable polycarbonate pH composite electrode has no temperature sensor, the meter compensates temperature from a separate temperature probe or from a value entered by hand. After moving the electrode to another meter, calibrate again: calibration data are stored in the meter, not in the electrode.

From sample to result

Sampling and keeping the sample

pH is one of the few parameters that cannot be preserved. Carbon dioxide from the air, biological activity and temperature change the value within minutes, so the common water standards ask for measurement on site or as soon as possible after sampling. Take the sample in a clean bottle, fill it to the top without an air space, close it, keep it cool and out of the light, and measure without delay. Do not add any preservative to the portion used for pH.

Preparing the unfillable polycarbonate pH composite electrode before calibration and measurement

  • Remove the protective cap from the sensor bulb at the bottom of the electrode and rinse the tip with distilled water; blot the drops, do not rub — rubbing charges the glass and slows the response.
  • The reference is sealed: there is no electrolyte level to check and no refill hole to open.

Calibrating the unfillable polycarbonate pH composite electrode

  1. Prepare fresh buffers at the same temperature as the samples and start the calibration on the meter.
  2. Immerse the tip in the first buffer, pH 7.00; wait for a stable reading and confirm the point.
  3. Rinse the tip with distilled water and blot the drops.
  4. Immerse the tip in the second buffer (pH 4.01 for acidic samples, pH 10.01 for alkaline); wait for a stable reading and confirm the point.
  5. The meter shows the electrode slope. If it is outside the limits given in the meter manual, clean the electrode, take fresh buffers and repeat the calibration.

Measuring

Stir gently or move the electrode slightly, wait for a stable value and read pH together with the temperature. Rinse the tip between samples.

pH in BOD and COD analysis

In a water laboratory the unfillable polycarbonate pH composite electrode works next to the BOD and COD methods, and both depend on it.

BOD (biochemical oxygen demand) is a biological test: micro-organisms consume oxygen for five days, and they do it properly only near neutral pH. The standard methods therefore require the pH of the sample to be checked before dilution and adjusted to roughly pH 6 – 8 with acid or alkali when it lies outside that range. A wrong pH at the start gives a BOD result that is too low.

COD (chemical oxygen demand) samples that cannot be analysed at once are preserved by acidifying to pH 2 or lower with sulfuric acid and stored cold. The pH check confirms that the preservation worked.

BOD and COD analysers, together with dissolved-oxygen and conductivity meters, are in the electrochemistry catalogue.

Care, storage and accessories

Storing the electrode

Never store the unfillable polycarbonate pH composite electrode dry and do not keep it in distilled water. Between measurements and overnight, keep the tip in the protective cap filled with 3 M KCl storage solution.

When the reading is slow or drifts

The usual causes are a membrane that has dried out, a blocked junction or old buffers. Soak the tip in storage solution, use fresh buffers and calibrate again.

Accessories

Electrode holder
Electrode holder
Keeps the electrode at a fixed height in the sample and protects the glass.

See the electrode holder →

pH buffers in bottles
pH buffers in bottles
pH 4.01, 7.00 and 10.01 in bottles, for laboratories that calibrate every day.

Buffers in the catalogue →

Electrode on the holder
Electrode on the holder
The arm lowers the electrode into the beaker and lifts it out for rinsing, without touching the glass.

How the holder is used →

  • pH buffers in sachets: single-use portions, always fresh, practical for field work and occasional calibration.
  • 3 M KCl solution: for storing the electrode between measurements.

Video: how the electrode holder is installed and used

Buffers, solutions, cables and holders are in the accessories section of the electrochemistry catalogue.

Frequently asked questions

Does the unfillable polycarbonate pH composite electrode fit my meter?

The unfillable polycarbonate pH composite electrode fits any meter with a BNC input. Meters with another input type need a different connection, so tell us the meter model before you order.

How often should I calibrate the unfillable polycarbonate pH composite electrode?

For routine work, calibrate at the start of each working day and whenever the sample type or temperature changes noticeably. For occasional measurements, calibrate before each series.

Where can I read more about electrodes?

The electrode catalogue has an electrode guide on sensor shapes, body materials and junctions, a full selection matrix and an overview of connectors. The electrochemistry overview covers pH, conductivity, dissolved oxygen and ion measurement.

Unfillable polycarbonate pH composite electrode and connector

Unfillable polycarbonate pH composite electrode PRO6136
PRO6136 · unfillable polycarbonate pH composite electrode · polycarbonate body, spherical bulb, BNC (Q9) connector
BNC (Q9) plug
BNC (Q9) plug
Goes into the BNC input of the meter.
Not sure this is the right electrode for your sample?
Send us the meter model, sample type, pH range and temperature — we will confirm the electrode or propose a better match from the catalogue.